Literature DB >> 20161023

Spatial distortion correction and crystal identification for MRI-compatible position-sensitive avalanche photodiode-based PET scanners.

Abhijit J Chaudhari1, Anand A Joshi, Yibao Wu, Richard M Leahy, Simon R Cherry, Ramsey D Badawi.   

Abstract

Position-sensitive avalanche photodiodes (PSAPDs) are gaining widespread acceptance in modern PET scanner designs, and owing to their relative insensitivity to magnetic fields, especially in those that are MRI-compatible. Flood histograms in PET scanners are used to determine the crystal of annihilation photon interaction and hence, for detector characterization and routine quality control. For PET detectors that use PSAPDs, flood histograms show a characteristic pincushion distortion when Anger logic is used for event positioning. A small rotation in the flood histogram is also observed when the detectors are placed in a magnetic field. We first present a general purpose automatic method for spatial distortion correction for flood histograms of PSAPD-based PET detectors when placed both inside and outside a MRI scanner. Analytical formulae derived for this scheme are based on a hybrid approach that combines desirable properties from two existing event positioning schemes. The rotation of the flood histogram due to the magnetic field is determined iteratively and is accounted for in the scheme. We then provide implementation details of a method for crystal identification we have previously proposed and evaluate it for cases when the PET detectors are both outside and in a magnetic field. In this scheme, Fourier analysis is used to generate a lower-order spatial approximation of the distortion-corrected PSAPD flood histogram, which we call the 'template'. The template is then registered to the flood histogram using a diffeomorphic iterative intensity-based warping scheme. The calculated deformation field is then applied to the segmentation of the template to obtain a segmentation of the flood histogram. A manual correction tool is also developed for exceptional cases. We present a quantitative assessment of the proposed distortion correction scheme and crystal identification method against conventional methods. Our results indicate that our proposed methods lead to a large reduction in manual labor and indeed can routinely be used for calibration and characterization studies in MRI-compatible PET scanners based on PSAPDs.

Entities:  

Year:  2009        PMID: 20161023      PMCID: PMC2749315          DOI: 10.1109/TNS.2009.2018841

Source DB:  PubMed          Journal:  IEEE Trans Nucl Sci        ISSN: 0018-9499            Impact factor:   1.679


  12 in total

1.  Consistent landmark and intensity-based image registration.

Authors:  H J Johnson; G E Christensen
Journal:  IEEE Trans Med Imaging       Date:  2002-05       Impact factor: 10.048

2.  SCINTILLATION CAMERA WITH MULTICHANNEL COLLIMATORS.

Authors:  H O ANGER
Journal:  J Nucl Med       Date:  1964-07       Impact factor: 10.057

3.  Evaluation of high performance data acquisition boards for simultaneous sampling of fast signals from PET detectors.

Authors:  Martin S Judenhofer; Bernd J Pichler; Simon R Cherry
Journal:  Phys Med Biol       Date:  2005-01-07       Impact factor: 3.609

4.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

Review 5.  A review of geometric transformations for nonrigid body registration.

Authors:  M Holden
Journal:  IEEE Trans Med Imaging       Date:  2008-01       Impact factor: 10.048

6.  A New Positioning Algorithm for Position-Sensitive Avalanche Photodiodes.

Authors:  Jin Zhang; Peter D Olcott; Craig S Levin
Journal:  IEEE Trans Nucl Sci       Date:  2007-06-01       Impact factor: 1.679

7.  Simultaneous PET-MRI: a new approach for functional and morphological imaging.

Authors:  Martin S Judenhofer; Hans F Wehrl; Danny F Newport; Ciprian Catana; Stefan B Siegel; Markus Becker; Axel Thielscher; Manfred Kneilling; Matthias P Lichy; Martin Eichner; Karin Klingel; Gerald Reischl; Stefan Widmaier; Martin Röcken; Robert E Nutt; Hans-Jürgen Machulla; Kamil Uludag; Simon R Cherry; Claus D Claussen; Bernd J Pichler
Journal:  Nat Med       Date:  2008-03-23       Impact factor: 53.440

8.  Automated image registration: I. General methods and intrasubject, intramodality validation.

Authors:  R P Woods; S T Grafton; C J Holmes; S R Cherry; J C Mazziotta
Journal:  J Comput Assist Tomogr       Date:  1998 Jan-Feb       Impact factor: 1.826

9.  Automated image registration: II. Intersubject validation of linear and nonlinear models.

Authors:  R P Woods; S T Grafton; J D Watson; N L Sicotte; J C Mazziotta
Journal:  J Comput Assist Tomogr       Date:  1998 Jan-Feb       Impact factor: 1.826

10.  Crystal identification in positron emission tomography using nonrigid registration to a Fourier-based template.

Authors:  Abhijit J Chaudhari; Anand A Joshi; Spencer L Bowen; Richard M Leahy; Simon R Cherry; Ramsey D Badawi
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

View more
  3 in total

1.  Translational imaging endpoints to predict treatment response to novel targeted anticancer agents.

Authors:  Natalie J Serkova
Journal:  Drug Resist Updat       Date:  2011-06-02       Impact factor: 18.500

2.  Performance characterization of a new high resolution PET scintillation detector.

Authors:  A Vandenbroucke; A M K Foudray; P D Olcott; C S Levin
Journal:  Phys Med Biol       Date:  2010-09-16       Impact factor: 3.609

3.  PET-MRI: Challenges and new directions.

Authors:  Aditya Daftary
Journal:  Indian J Nucl Med       Date:  2010-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.