Literature DB >> 28269680

Effects of coplanar shielding for high field MRI.

Joseph V Rispoli, Matthew D Wilcox, Samantha By, Steven M Wright, Mary P McDougall.   

Abstract

This work investigates the efficacy of "coplanar shielding," in which copper shields are oriented concentric and coplanar to the RF coils rather than implemented as a full ground plane behind them. Following FDTD simulations to determine optimal shielding parameters, two coil geometries were constructed: a circular loop surface coil and a half-volume five-element receive array. Each was evaluated using bench measurements with and without coplanar shielding. Imaging, including accelerated SENSE imaging, was performed with the shielded and unshielded receive arrays on a whole-body 7T scanner. Results from modeled and fabricated coils showed good agreement with improvements in Q factors for all cases. Imaging showed substantial improvements in SNR and g-factors for the coplanar shielded array.

Entities:  

Mesh:

Year:  2016        PMID: 28269680      PMCID: PMC5548299          DOI: 10.1109/EMBC.2016.7592157

Source DB:  PubMed          Journal:  Conf Proc IEEE Eng Med Biol Soc        ISSN: 1557-170X


  11 in total

1.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

2.  Specific coil design for SENSE: a six-element cardiac array.

Authors:  M Weiger; K P Pruessmann; C Leussler; P Röschmann; P Boesiger
Journal:  Magn Reson Med       Date:  2001-03       Impact factor: 4.668

3.  7T vs. 4T: RF power, homogeneity, and signal-to-noise comparison in head images.

Authors:  J T Vaughan; M Garwood; C M Collins; W Liu; L DelaBarre; G Adriany; P Andersen; H Merkle; R Goebel; M B Smith; K Ugurbil
Journal:  Magn Reson Med       Date:  2001-07       Impact factor: 4.668

4.  A conformal transceive array for 7 T neuroimaging.

Authors:  Kyle M Gilbert; Jean-Guy Belliveau; Andrew T Curtis; Joseph S Gati; L Martyn Klassen; Ravi S Menon
Journal:  Magn Reson Med       Date:  2011-08-16       Impact factor: 4.668

5.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

6.  Transmit/receive radiofrequency coil with individually shielded elements.

Authors:  Kyle M Gilbert; Andrew T Curtis; Joseph S Gati; L Martyn Klassen; Lauren E Villemaire; Ravi S Menon
Journal:  Magn Reson Med       Date:  2010-07-20       Impact factor: 4.668

7.  Parallel imaging performance as a function of field strength--an experimental investigation using electrodynamic scaling.

Authors:  Florian Wiesinger; Pierre-Francois Van de Moortele; Gregor Adriany; Nicola De Zanche; Kamil Ugurbil; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

8.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

9.  Noise figure limits for circular loop MR coils.

Authors:  Ananda Kumar; William A Edelstein; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2009-05       Impact factor: 4.668

10.  On consideration of radiated power in RF field simulations for MRI.

Authors:  Wanzhan Liu; Chien-ping Kao; Christopher M Collins; Michael B Smith; Qing X Yang
Journal:  Magn Reson Med       Date:  2012-04-03       Impact factor: 4.668

View more
  2 in total

1.  A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

Authors:  Romina Del Bosque; Jiaming Cui; Stephen Ogier; Sergey Cheshkov; Ivan E Dimitrov; Craig Malloy; Steven M Wright; Mary McDougall
Journal:  Magn Reson Med       Date:  2020-08-09       Impact factor: 4.668

2.  A flexible MRI coil based on a cable conductor and applied to knee imaging.

Authors:  Bili Wang; Syed S Siddiq; Jerzy Walczyk; Mary Bruno; Iman Khodarahmi; Inge M Brinkmann; Robert Rehner; Karthik Lakshmanan; Jan Fritz; Ryan Brown
Journal:  Sci Rep       Date:  2022-09-02       Impact factor: 4.996

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.