Literature DB >> 18057975

Optimized quadrature surface coil designs.

Ananda Kumar1, Paul A Bottomley.   

Abstract

BACKGROUND: Quadrature surface MRI/MRS detectors comprised of circular loop and figure-8 or butterfly-shaped coils offer improved signal-to-noise-ratios (SNR) compared to single surface coils, and reduced power and specific absorption rates (SAR) when used for MRI excitation. While the radius of the optimum loop coil for performing MRI at depth d in a sample is known, the optimum geometry for figure-8 and butterfly coils is not.
MATERIALS AND METHODS: The geometries of figure-8 and square butterfly detector coils that deliver the optimum SNR are determined numerically by the electromagnetic method of moments. Figure-8 and loop detectors are then combined to create SNR-optimized quadrature detectors whose theoretical and experimental SNR performance are compared with a novel quadrature detector comprised of a strip and a loop, and with two overlapped loops optimized for the same depth at 3 T. The quadrature detection efficiency and local SAR during transmission for the three quadrature configurations are analyzed and compared.
RESULTS: The SNR-optimized figure-8 detector has loop radius r8 approximately 0.6d, so r8/r0 approximately 1.3 in an optimized quadrature detector at 3 T. The optimized butterfly coil has side length approximately d and crossover angle of > or = 150 degrees at the center.
CONCLUSIONS: These new design rules for figure-8 and butterfly coils optimize their performance as linear and quadrature detectors.

Entities:  

Mesh:

Year:  2007        PMID: 18057975      PMCID: PMC2588669          DOI: 10.1007/s10334-007-0090-2

Source DB:  PubMed          Journal:  MAGMA        ISSN: 0968-5243            Impact factor:   2.310


  17 in total

1.  Lumped-element planar strip array (LPSA) for parallel MRI.

Authors:  Ray F Lee; Christopher J Hardy; Daniel K Sodickson; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

2.  Polarization of the RF field in a human head at high field: a study with a quadrature surface coil at 7.0 T.

Authors:  Jinghua Wang; Qing X Yang; Xiaoliang Zhang; Christopher M Collins; Michael B Smith; Xiao-Hong Zhu; Gregor Adriany; Kamil Ugurbil; Wei Chen
Journal:  Magn Reson Med       Date:  2002-08       Impact factor: 4.668

3.  Homogeneous tissue model estimates of RF power deposition in human NMR studies. Local elevations predicted in surface coil decoupling.

Authors:  P A Bottomley; P B Roemer
Journal:  Ann N Y Acad Sci       Date:  1992-03-31       Impact factor: 5.691

4.  Parallel imaging performance as a function of field strength--an experimental investigation using electrodynamic scaling.

Authors:  Florian Wiesinger; Pierre-Francois Van de Moortele; Gregor Adriany; Nicola De Zanche; Kamil Ugurbil; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2004-11       Impact factor: 4.668

5.  Optimizing the intrinsic signal-to-noise ratio of MRI strip detectors.

Authors:  Ananda Kumar; Paul A Bottomley
Journal:  Magn Reson Med       Date:  2006-07       Impact factor: 4.668

6.  Electromagnetic fields of surface coil in vivo NMR at high frequencies.

Authors:  J R Keltner; J W Carlson; M S Roos; S T Wong; T L Wong; T F Budinger
Journal:  Magn Reson Med       Date:  1991-12       Impact factor: 4.668

7.  SAR and B1 field distributions in a heterogeneous human head model within a birdcage coil. Specific energy absorption rate.

Authors:  C M Collins; S Li; M B Smith
Journal:  Magn Reson Med       Date:  1998-12       Impact factor: 4.668

8.  Quadrature detection in the laboratory frame.

Authors:  D I Hoult; C N Chen; V J Sank
Journal:  Magn Reson Med       Date:  1984-09       Impact factor: 4.668

9.  Proton-decoupled, Overhauser-enhanced, spatially localized carbon-13 spectroscopy in humans.

Authors:  P A Bottomley; C J Hardy; P B Roemer; O M Mueller
Journal:  Magn Reson Med       Date:  1989-12       Impact factor: 4.668

10.  Magnetic resonance imaging can cause focal heating in a nonuniform phantom.

Authors:  P L Davis; C Shang; L Talagala; A W Pasculle
Journal:  IEEE Trans Biomed Eng       Date:  1993-12       Impact factor: 4.538

View more
  11 in total

1.  A formalism to investigate the optimal transmit efficiency in radiofrequency shimming.

Authors:  Ioannis P Georgakis; Athanasios G Polimeridis; Riccardo Lattanzi
Journal:  NMR Biomed       Date:  2020-07-28       Impact factor: 4.044

2.  Over-overlapped loop arrays: A numerical study.

Authors:  Ming Lu; John C Gore; Xinqiang Yan
Journal:  Magn Reson Imaging       Date:  2020-07-18       Impact factor: 2.546

3.  Ideal current patterns yielding optimal signal-to-noise ratio and specific absorption rate in magnetic resonance imaging: computational methods and physical insights.

Authors:  Riccardo Lattanzi; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2011-11-29       Impact factor: 4.668

4.  Maximum efficiency radiofrequency shimming: Theory and initial application for hip imaging at 7 tesla.

Authors:  Cem Murat Deniz; Ryan Brown; Riccardo Lattanzi; Leeor Alon; Daniel K Sodickson; Yudong Zhu
Journal:  Magn Reson Med       Date:  2012-06-19       Impact factor: 4.668

5.  (17)O relaxation times in the rat brain at 16.4 tesla.

Authors:  Hannes M Wiesner; Dávid Z Balla; G Shajan; Klaus Scheffler; Kâmil Uğurbil; Wei Chen; Kâmil Uludağ; Rolf Pohmann
Journal:  Magn Reson Med       Date:  2015-06-22       Impact factor: 4.668

6.  Optimization of a transmit/receive surface coil for squirrel monkey spinal cord imaging.

Authors:  Ming Lu; Feng Wang; Li Min Chen; John C Gore; Xinqiang Yan
Journal:  Magn Reson Imaging       Date:  2020-02-19       Impact factor: 2.546

7.  Birdcage volume coils and magnetic resonance imaging: a simple experiment for students.

Authors:  Dwight E Vincent; Tianhao Wang; Thalia A K Magyar; Peni I Jacob; Richard Buist; Melanie Martin
Journal:  J Biol Eng       Date:  2017-11-02       Impact factor: 4.355

8.  Partially orthogonal resonators for magnetic resonance imaging.

Authors:  Jorge Chacon-Caldera; Matthias Malzacher; Lothar R Schad
Journal:  Sci Rep       Date:  2017-02-10       Impact factor: 4.379

9.  Diffusion tensor imaging of articular cartilage at 3T correlates with histology and biomechanics in a mechanical injury model.

Authors:  Uran Ferizi; Ignacio Rossi; Youjin Lee; Matin Lendhey; Jason Teplensky; Oran D Kennedy; Thorsten Kirsch; Jenny Bencardino; José G Raya
Journal:  Magn Reson Med       Date:  2016-07-25       Impact factor: 3.737

10.  Planar quadrature RF transceiver design using common-mode differential-mode (CMDM) transmission line method for 7T MR imaging.

Authors:  Ye Li; Baiying Yu; Yong Pang; Daniel B Vigneron; Xiaoliang Zhang
Journal:  PLoS One       Date:  2013-11-12       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.