Literature DB >> 18094746

An overview of fast convergent ordered-subsets reconstruction methods for emission tomography based on the incremental EM algorithm.

Ing-Tsung Hsiao1, Parmeshwar Khurd, Anand Rangarajan, Gene Gindi.   

Abstract

Statistical reconstruction has become popular in emission computed tomography but suffers slow convergence (to the MAP or ML solution). Methods proposed to address this problem include the fast but non-convergent OSEM and the convergent RAMLA [1] for the ML case, and the convergent BSREM [2], relaxed OS-SPS and modified BSREM [3] for the MAP case. The convergent algorithms required a user-determined relaxation schedule. We proposed fast convergent OS reconstruction algorithms for both ML and MAP cases, called COSEM (Complete-data OSEM), which avoid the use of a relaxation schedule while maintaining convergence. COSEM is a form of incremental EM algorithm. Here, we provide a derivation of our COSEM algorithms and demonstrate COSEM using simulations. At early iterations, COSEM-ML is typically slower than RAMLA, and COSEM-MAP is typically slower than optimized BSREM while remaining much faster than conventional MAP-EM. We discuss how COSEM may be modified to overcome these limitations.

Entities:  

Year:  2006        PMID: 18094746      PMCID: PMC1826269          DOI: 10.1016/j.nima.2006.08.152

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  12 in total

1.  Theoretical study of lesion detectability of MAP reconstruction using computer observers.

Authors:  J Qi; R H Huesman
Journal:  IEEE Trans Med Imaging       Date:  2001-08       Impact factor: 10.048

2.  Fast EM-like methods for maximum "a posteriori" estimates in emission tomography.

Authors:  A R de Pierro; M E Beleza Yamagishi
Journal:  IEEE Trans Med Imaging       Date:  2001-04       Impact factor: 10.048

3.  An accelerated convergent ordered subsets algorithm for emission tomography.

Authors:  Ing-Tsung Hsiao; Anand Rangarajan; Parmeshwar Khurd; Gene Gindi
Journal:  Phys Med Biol       Date:  2004-06-07       Impact factor: 3.609

4.  Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): applications to tomography.

Authors:  J A Fessler
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

5.  A unified approach to statistical tomography using coordinate descent optimization.

Authors:  C A Bouman; K Sauer
Journal:  IEEE Trans Image Process       Date:  1996       Impact factor: 10.856

6.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

7.  Accelerated image reconstruction using ordered subsets of projection data.

Authors:  H M Hudson; R S Larkin
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

8.  Fast gradient-based methods for Bayesian reconstruction of transmission and emission PET images.

Authors:  E U Mumcuoglu; R Leahy; S R Cherry; Z Zhou
Journal:  IEEE Trans Med Imaging       Date:  1994       Impact factor: 10.048

9.  A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.

Authors:  J Browne; A B de Pierro
Journal:  IEEE Trans Med Imaging       Date:  1996       Impact factor: 10.048

10.  Maximum likelihood reconstruction for emission tomography.

Authors:  L A Shepp; Y Vardi
Journal:  IEEE Trans Med Imaging       Date:  1982       Impact factor: 10.048

View more
  3 in total

Review 1.  Digital mammography imaging: breast tomosynthesis and advanced applications.

Authors:  Mark A Helvie
Journal:  Radiol Clin North Am       Date:  2010-09       Impact factor: 2.303

2.  Regularized image reconstruction algorithms for dual-isotope myocardial perfusion SPECT (MPS) imaging using a cross-tracer prior.

Authors:  Xin He; Lishui Cheng; Jeffrey A Fessler; Eric C Frey
Journal:  IEEE Trans Med Imaging       Date:  2010-10-14       Impact factor: 10.048

Review 3.  Monte Carlo methods for device simulations in radiation therapy.

Authors:  Hyojun Park; Harald Paganetti; Jan Schuemann; Xun Jia; Chul Hee Min
Journal:  Phys Med Biol       Date:  2021-09-14       Impact factor: 4.174

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.