Literature DB >> 18285134

Mean and variance of implicitly defined biased estimators (such as penalized maximum likelihood): applications to tomography.

J A Fessler1.   

Abstract

Many estimators in signal processing problems are defined implicitly as the maximum of some objective function. Examples of implicitly defined estimators include maximum likelihood, penalized likelihood, maximum a posteriori, and nonlinear least squares estimation. For such estimators, exact analytical expressions for the mean and variance are usually unavailable. Therefore, investigators usually resort to numerical simulations to examine the properties of the mean and variance of such estimators. This paper describes approximate expressions for the mean and variance of implicitly defined estimators of unconstrained continuous parameters. We derive the approximations using the implicit function theorem, the Taylor expansion, and the chain rule. The expressions are defined solely in terms of the partial derivatives of whatever objective function one uses for estimation. As illustrations, we demonstrate that the approximations work well in two tomographic imaging applications with Poisson statistics. We also describe a "plug-in" approximation that provides a remarkably accurate estimate of variability even from a single noisy Poisson sinogram measurement. The approximations should be useful in a wide range of estimation problems.

Year:  1996        PMID: 18285134     DOI: 10.1109/83.491322

Source DB:  PubMed          Journal:  IEEE Trans Image Process        ISSN: 1057-7149            Impact factor:   10.856


  68 in total

1.  Regularization designs for uniform spatial resolution and noise properties in statistical image reconstruction for 3-D X-ray CT.

Authors:  Jang Hwan Cho; Jeffrey A Fessler
Journal:  IEEE Trans Med Imaging       Date:  2014-10-28       Impact factor: 10.048

2.  Linear approach to axial resolution in elasticity imaging.

Authors:  Jie Liu; Craig K Abbey; Michael F Insana
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2004-06       Impact factor: 2.725

3.  A modified uniform Cramer-Rao bound for multiple pinhole aperture design.

Authors:  L J Meng; N H Clinthorne
Journal:  IEEE Trans Med Imaging       Date:  2004-07       Impact factor: 10.048

Review 4.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

5.  Rapid Computation of LROC Figures of Merit Using Numerical Observers (for SPECT/PET Reconstruction).

Authors:  Parmeshwar Khurd; Gene Gindi
Journal:  IEEE Trans Nucl Sci       Date:  2003       Impact factor: 1.679

6.  Band-restricted estimation of noise variance in filtered backprojection reconstructions using repeated scans.

Authors:  Adam Wunderlich; Frederic Noo
Journal:  IEEE Trans Med Imaging       Date:  2010-03-15       Impact factor: 10.048

7.  A novel approach to assess the treatment response using Gaussian random field in PET.

Authors:  Mengdie Wang; Ning Guo; Guangshu Hu; Georges El Fakhri; Hui Zhang; Quanzheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

8.  Data analysis in emission tomography using emission-count posteriors.

Authors:  Arkadiusz Sitek
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

9.  Sparsity-regularized image reconstruction of decomposed K-edge data in spectral CT.

Authors:  Qiaofeng Xu; Alex Sawatzky; Mark A Anastasio; Carsten O Schirra
Journal:  Phys Med Biol       Date:  2014-04-28       Impact factor: 3.609

10.  New Theoretical Results on Channelized Hotelling Observer Performance Estimation with Known Difference of Class Means.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Nucl Sci       Date:  2013-01-11       Impact factor: 1.679

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.