Literature DB >> 18238264

Maximum likelihood reconstruction for emission tomography.

L A Shepp, Y Vardi.   

Abstract

Previous models for emission tomography (ET) do not distinguish the physics of ET from that of transmission tomography. We give a more accurate general mathematical model for ET where an unknown emission density lambda = lambda(x, y, z) generates, and is to be reconstructed from, the number of counts n(*)(d) in each of D detector units d. Within the model, we give an algorithm for determining an estimate lambdainsertion mark of lambda which maximizes the probability p(n(*)|lambda) of observing the actual detector count data n(*) over all possible densities lambda. Let independent Poisson variables n(b) with unknown means lambda(b), b = 1, ..., B represent the number of unobserved emissions in each of B boxes (pixels) partitioning an object containing an emitter. Suppose each emission in box b is detected in detector unit d with probability p(b, d), d = 1, ..., D with p(b,d) a one-step transition matrix, assumed known. We observe the total number n(*) = n(*)(d) of emissions in each detector unit d and want to estimate the unknown lambda = lambda(b), b = 1, ..., B. For each lambda, the observed data n(*) has probability or likelihood p(n(*)|lambda). The EM algorithm of mathematical statistics starts with an initial estimate lambda(0) and gives the following simple iterative procedure for obtaining a new estimate lambdainsertion mark(new), from an old estimate lambdainsertion mark(old), to obtain lambdainsertion mark(k), k = 1, 2, ..., lambdainsertion mark(new)(b)= lambdainsertion mark(old)(b)Sum of (n(*)p(b,d) from d=1 to D/Sum of lambdainsertion mark()old(b('))p(b('),d) from b(')=1 to B), b=1,...B.

Year:  1982        PMID: 18238264     DOI: 10.1109/TMI.1982.4307558

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  368 in total

1.  Clinical implication of down-scatter in attenuation-corrected myocardial SPECT.

Authors:  H Almquist; H Arheden; A H Arvidsson; O Pahlm; J Palmer
Journal:  J Nucl Cardiol       Date:  1999 Jul-Aug       Impact factor: 5.952

2.  Automatic quantification of left ventricular ejection fraction from gated blood pool SPECT.

Authors:  S D Van Kriekinge; D S Berman; G Germano
Journal:  J Nucl Cardiol       Date:  1999 Sep-Oct       Impact factor: 5.952

3.  Unmatched projector/backprojector pairs in an iterative reconstruction algorithm.

Authors:  G L Zeng; G T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2000-05       Impact factor: 10.048

4.  A combined static-dynamic single-dose imaging protocol to compare quantitative dynamic SPECT with static conventional SPECT.

Authors:  Maria Sciammarella; Uttam M Shrestha; Youngho Seo; Grant T Gullberg; Elias H Botvinick
Journal:  J Nucl Cardiol       Date:  2017-08-03       Impact factor: 5.952

5.  Maximum Likelihood Event Estimation and List-mode Image Reconstruction on GPU Hardware.

Authors:  Luca Caucci; Lars R Furenlid; Harrison H Barrett
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2009-10-24

6.  Estimation of attenuation maps from scatter and photopeak window single photon-emission computed tomographic images of technetium 99m-labeled sestamibi.

Authors:  T S Pan; M A King; D S Luo; S T Dahlberg; B J Villegas
Journal:  J Nucl Cardiol       Date:  1997 Jan-Feb       Impact factor: 5.952

7.  Comparison of 3D OS-EM and 4D MAP-RBI-EM reconstruction algorithms for cardiac motion abnormality classification using a motion observer.

Authors:  Jing Tang; Taek-Soo Lee; Xin He; W Paul Segars; Benjamin M W Tsui
Journal:  IEEE Trans Nucl Sci       Date:  2010-08-26       Impact factor: 1.679

8.  Data analysis in emission tomography using emission-count posteriors.

Authors:  Arkadiusz Sitek
Journal:  Phys Med Biol       Date:  2012-10-03       Impact factor: 3.609

9.  Order of magnitude sensitivity increase in X-ray Fluorescence Computed Tomography (XFCT) imaging with an optimized spectro-spatial detector configuration: theory and simulation.

Authors:  Moiz Ahmad; Magdalena Bazalova; Liangzhong Xiang; Lei Xing
Journal:  IEEE Trans Med Imaging       Date:  2014-05       Impact factor: 10.048

10.  Efficient fully 3D list-mode TOF PET image reconstruction using a factorized system matrix with an image domain resolution model.

Authors:  Jian Zhou; Jinyi Qi
Journal:  Phys Med Biol       Date:  2014-01-17       Impact factor: 3.609

View more