Literature DB >> 18215950

A row-action alternative to the EM algorithm for maximizing likelihood in emission tomography.

J Browne1, A B de Pierro.   

Abstract

The maximum likelihood (ML) approach to estimating the radioactive distribution in the body cross section has become very popular among researchers in emission computed tomography (ECT) since it has been shown to provide very good images compared to those produced with the conventional filtered backprojection (FBP) algorithm. The expectation maximization (EM) algorithm is an often-used iterative approach for maximizing the Poisson likelihood in ECT because of its attractive theoretical and practical properties. Its major disadvantage is that, due to its slow rate of convergence, a large amount of computation is often required to achieve an acceptable image. Here, the authors present a row-action maximum likelihood algorithm (RAMLA) as an alternative to the EM algorithm for maximizing the Poisson likelihood in ECT. The authors deduce the convergence properties of this algorithm and demonstrate by way of computer simulations that the early iterates of RAMLA increase the Poisson likelihood in ECT at an order of magnitude faster that the standard EM algorithm. Specifically, the authors show that, from the point of view of measuring total radionuclide uptake in simulated brain phantoms, iterations 1, 2, 3, and 4 of RAMLA perform at least as well as iterations 45, 60, 70, and 80, respectively, of EM. Moreover, the authors show that iterations 1, 2, 3, and 4 of RAMLA achieve comparable likelihood values as iterations 45, 60, 70, and 80, respectively, of EM. The authors also present a modified version of a recent fast ordered subsets EM (OS-EM) algorithm and show that RAMLA is a special case of this modified OS-EM. Furthermore, the authors show that their modification converges to a ML solution whereas the standard OS-EM does not.

Entities:  

Year:  1996        PMID: 18215950     DOI: 10.1109/42.538946

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  43 in total

1.  Attenuation correction in emission tomography using the emission data--A review.

Authors:  Yannick Berker; Yusheng Li
Journal:  Med Phys       Date:  2016-02       Impact factor: 4.071

2.  Image reconstruction for positron emission tomography using fuzzy nonlinear anisotropic diffusion penalty.

Authors:  Hongqing Zhu; Huazhong Shu; Jian Zhou; Christine Toumoulin; Limin Luo
Journal:  Med Biol Eng Comput       Date:  2006-10-24       Impact factor: 2.602

3.  Time-of-flight PET image reconstruction using origin ensembles.

Authors:  Christian Wülker; Arkadiusz Sitek; Sven Prevrhal
Journal:  Phys Med Biol       Date:  2015-02-10       Impact factor: 3.609

4.  An overview of fast convergent ordered-subsets reconstruction methods for emission tomography based on the incremental EM algorithm.

Authors:  Ing-Tsung Hsiao; Parmeshwar Khurd; Anand Rangarajan; Gene Gindi
Journal:  Nucl Instrum Methods Phys Res A       Date:  2006-12-20       Impact factor: 1.455

5.  Fast iterative image reconstruction methods for fully 3D multispectral bioluminescence tomography.

Authors:  Sangtae Ahn; Abhijit J Chaudhari; Felix Darvas; Charles A Bouman; Richard M Leahy
Journal:  Phys Med Biol       Date:  2008-06-30       Impact factor: 3.609

Review 6.  Brain single-photon emission CT physics principles.

Authors:  R Accorsi
Journal:  AJNR Am J Neuroradiol       Date:  2008-06-26       Impact factor: 3.825

7.  Myocardial perfusion imaging is feasible for infarct size quantification in mice using a clinical single-photon emission computed tomography system equipped with pinhole collimators.

Authors:  Tim Wollenweber; Christian Zach; Christoph Rischpler; Rebekka Fischer; Sebastian Nowak; Stephan G Nekolla; Michael Gröbner; Christopher Ubleis; Gerald Assmann; Josef Müller-Höcker; Christian La Fougére; Guido Böning; Paul Cumming; Wolfgang-Michael Franz; Marcus Hacker
Journal:  Mol Imaging Biol       Date:  2009-11-25       Impact factor: 3.488

8.  A residual correction method for high-resolution PET reconstruction with application to on-the-fly Monte Carlo based model of positron range.

Authors:  Lin Fu; Jinyi Qi
Journal:  Med Phys       Date:  2010-02       Impact factor: 4.071

9.  Iterative PET Image Reconstruction Using Translation Invariant Wavelet Transform.

Authors:  Jian Zhou; Lotfi Senhadji; Jean-Louis Coatrieux; Limin Luo
Journal:  IEEE Trans Nucl Sci       Date:  2009-02       Impact factor: 1.679

10.  [18F]FDG-PET predicts complete pathological response of breast cancer to neoadjuvant chemotherapy.

Authors:  Alina Berriolo-Riedinger; Claude Touzery; Jean-Marc Riedinger; Michel Toubeau; Bruno Coudert; Laurent Arnould; Christophe Boichot; Alexandre Cochet; Pierre Fumoleau; François Brunotte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-06-20       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.