Literature DB >> 28232236

Vacuum level effects on gait characteristics for unilateral transtibial amputees with elevated vacuum suspension.

Hang Xu1, Kasey Greenland2, Donald Bloswick3, Jie Zhao4, Andrew Merryweather5.   

Abstract

BACKGROUND: The elevated vacuum suspension system has demonstrated unique health benefits for amputees, but the effect of vacuum pressure values on gait characteristics is still unclear. The purpose of this study was to investigate the effects of elevated vacuum levels on temporal parameters, kinematics and kinetics for unilateral transtibial amputees.
METHODS: Three-dimensional gait analysis was conducted in 9 unilateral transtibial amputees walking at a controlled speed with five vacuum levels ranging from 0 to 20inHg, and also in 9 able-bodied subjects walking at self-preferred speed. Repeated ANOVA and Dunnett's t-test were performed to determine the effect of vacuum level and limb for within subject and between groups.
FINDINGS: The effect of vacuum level significantly affected peak hip external rotation and external knee adduction moment. Maximum braking and propulsive ground reaction forces generally increased for the residual limb and decreased for the intact limb with increasing vacuum. Additionally, the intact limb experienced an increased loading due to gait asymmetry for several variables.
INTERPRETATION: There was no systematic vacuum level effect on gait. Higher vacuum levels, such as 15 and 20inHg, were more comfortable and provided some relief to the intact limb, but may also increase the risk of osteoarthritis of the residual limb due to the increased peak external hip and knee adduction moments. Very low vacuum should be avoided because of the negative effects on gait symmetry. A moderate vacuum level at 15inHg is suggested for unilateral transtibial amputees with elevated vacuum suspension.
Copyright © 2017 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Amputees; Biomechanics; Comfort; Gait; Prosthesis; Vacuum level

Mesh:

Year:  2017        PMID: 28232236      PMCID: PMC5404825          DOI: 10.1016/j.clinbiomech.2017.02.008

Source DB:  PubMed          Journal:  Clin Biomech (Bristol, Avon)        ISSN: 0268-0033            Impact factor:   2.063


  21 in total

1.  The functional demands on the intact limb during walking for active trans-femoral and trans-tibial amputees.

Authors:  L Nolan; A Lees
Journal:  Prosthet Orthot Int       Date:  2000-08       Impact factor: 1.895

2.  A comparison of trans-tibial amputee suction and vacuum socket conditions.

Authors:  W J Board; G M Street; C Caspers
Journal:  Prosthet Orthot Int       Date:  2001-12       Impact factor: 1.895

3.  Comparison of interface pressures with pin and suction suspension systems.

Authors:  Tracy L Beil; Glenn M Street
Journal:  J Rehabil Res Dev       Date:  2004 Nov-Dec

4.  Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.

Authors:  Tracy L Beil; Glenn M Street; Steven J Covey
Journal:  J Rehabil Res Dev       Date:  2002 Nov-Dec

Review 5.  Does knee malalignment increase the risk of development and progression of knee osteoarthritis? A systematic review.

Authors:  Stephanie Tanamas; Fahad S Hanna; Flavia M Cicuttini; Anita E Wluka; Patricia Berry; Donna M Urquhart
Journal:  Arthritis Rheum       Date:  2009-04-15

Review 6.  Biomechanics and physiological parameters during gait in lower-limb amputees: a systematic review.

Authors:  Yoshimasa Sagawa; Katia Turcot; Stéphane Armand; Andre Thevenon; Nicolas Vuillerme; Eric Watelain
Journal:  Gait Posture       Date:  2011-03-10       Impact factor: 2.840

7.  Basic gait parameters: reference data for normal subjects, 10-79 years of age.

Authors:  T Oberg; A Karsznia; K Oberg
Journal:  J Rehabil Res Dev       Date:  1993

Review 8.  Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use.

Authors:  Robert Gailey; Kerry Allen; Julie Castles; Jennifer Kucharik; Mariah Roeder
Journal:  J Rehabil Res Dev       Date:  2008

9.  Sex modifies the relationship between age and gait: a population-based study of older adults.

Authors:  Michele L Callisaya; Leigh Blizzard; Michael D Schmidt; Jennifer L McGinley; Velandai K Srikanth
Journal:  J Gerontol A Biol Sci Med Sci       Date:  2008-02       Impact factor: 6.053

10.  The prevalence of osteoarthritis of the intact hip and knee among traumatic leg amputees.

Authors:  Pieter A Struyf; Caroline M van Heugten; Minou W Hitters; Rob J Smeets
Journal:  Arch Phys Med Rehabil       Date:  2009-03       Impact factor: 3.966

View more
  3 in total

1.  Modeling the mechanics of elevated vacuum systems in prosthetic sockets.

Authors:  Robert T Youngblood; Brian J Hafner; Joseph M Czerniecki; Jacob T Brzostowski; Katheryn J Allyn; Joan E Sanders
Journal:  Med Eng Phys       Date:  2020-07-28       Impact factor: 2.242

2.  Real time monitoring of transtibial elevated vacuum prostheses: A case series on socket air pressure.

Authors:  Katherine R Schoepp; Jonathon S Schofield; David Home; Michael R Dawson; Edmond Lou; McNiel Keri; Paul D Marasco; Jacqueline S Hebert
Journal:  PLoS One       Date:  2018-10-22       Impact factor: 3.240

3.  Effects of the unity vacuum suspension system on transtibial gait for simulated non-level surfaces.

Authors:  Gabrielle Thibault; Hossein Gholizadeh; Emily Sinitski; Natalie Baddour; Edward D Lemaire
Journal:  PLoS One       Date:  2018-06-14       Impact factor: 3.240

  3 in total