Literature DB >> 34112873

Residual limb volume fluctuations in transfemoral amputees.

Linda Paternò1,2, Michele Ibrahimi3,4, Elisa Rosini3,4, Giuseppe Menfi3,4, Vito Monaco3,4,5, Emanuele Gruppioni6, Leonardo Ricotti3,4, Arianna Menciassi3,4.   

Abstract

This study constitutes the first attempt to systematically quantify residual limb volume fluctuations in transfemoral amputees. The study was carried out on 24 amputees to investigate variations due to prosthesis doffing, physical activity, and testing time. A proper experimental set-up was designed, including a 3D optical scanner to improve precision and acceptability by amputees. The first test session aimed at measuring residual limb volume at 7 time-points, with 10 min intervals, after prosthesis doffing. This allowed for evaluating the time required for volume stabilization after prosthesis removal, for each amputee. In subsequent sessions, 16 residual limb scans in a day for each amputee were captured to evaluate volume fluctuations due to prosthesis removal and physical activity, in two times per day (morning and afternoon). These measurements were repeated in three different days, a week apart from each other, for a total of 48 scans for each amputee. Volume fluctuations over time after prosthesis doffing showed a two-term decay exponential trend (R2 = 0.97), with the highest variation in the initial 10 min and an average stabilization time of 30 min. A statistically significant increase in residual limb volume following both prosthesis removal and physical activity was verified. No differences were observed between measures collected in the morning and in the afternoon.Clinical Trials.gov ID: NCT04709367.

Entities:  

Year:  2021        PMID: 34112873     DOI: 10.1038/s41598-021-91647-9

Source DB:  PubMed          Journal:  Sci Rep        ISSN: 2045-2322            Impact factor:   4.379


  34 in total

1.  A comparison of trans-tibial amputee suction and vacuum socket conditions.

Authors:  W J Board; G M Street; C Caspers
Journal:  Prosthet Orthot Int       Date:  2001-12       Impact factor: 1.895

Review 2.  State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review.

Authors:  A F Mak; M Zhang; D A Boone
Journal:  J Rehabil Res Dev       Date:  2001 Mar-Apr

3.  Walking in a vacuum-assisted socket shifts the stump fluid balance.

Authors:  J Goswami; R Lynn; G Street; M Harlander
Journal:  Prosthet Orthot Int       Date:  2003-08       Impact factor: 1.895

Review 4.  Residual limb volume change: systematic review of measurement and management.

Authors:  Joan E Sanders; Stefania Fatone
Journal:  J Rehabil Res Dev       Date:  2011

5.  Shape and volume change in the transtibial residuum over the short term: preliminary investigation of six subjects.

Authors:  Santosh G Zachariah; Rakesh Saxena; John R Fergason; Joan E Sanders
Journal:  J Rehabil Res Dev       Date:  2004-09

6.  Interface pressures during ambulation using suction and vacuum-assisted prosthetic sockets.

Authors:  Tracy L Beil; Glenn M Street; Steven J Covey
Journal:  J Rehabil Res Dev       Date:  2002 Nov-Dec

7.  Sockets for Limb Prostheses: A Review of Existing Technologies and Open Challenges.

Authors:  Linda Paterno; Michele Ibrahimi; Emanuele Gruppioni; Arianna Menciassi; Leonardo Ricotti
Journal:  IEEE Trans Biomed Eng       Date:  2018-01-23       Impact factor: 4.538

8.  Volume fluctuations in the residual limbs of lower limb amputees.

Authors:  G R Fernie; P J Holliday
Journal:  Arch Phys Med Rehabil       Date:  1982-04       Impact factor: 3.966

9.  Determinants of skin problems of the stump in lower-limb amputees.

Authors:  Henk E Meulenbelt; Jan H Geertzen; Marcel F Jonkman; Pieter U Dijkstra
Journal:  Arch Phys Med Rehabil       Date:  2009-01       Impact factor: 3.966

View more
  3 in total

1.  Redundancy Reduction for Sensor Deployment in Prosthetic Socket: A Case Study.

Authors:  Wenyao Zhu; Yizhi Chen; Siu-Teing Ko; Zhonghai Lu
Journal:  Sensors (Basel)       Date:  2022-04-19       Impact factor: 3.847

2.  The Use of Smartphone Photogrammetry to Digitise Transtibial Sockets: Optimisation of Method and Quantitative Evaluation of Suitability.

Authors:  Sean Cullen; Ruth Mackay; Amir Mohagheghi; Xinli Du
Journal:  Sensors (Basel)       Date:  2021-12-16       Impact factor: 3.576

3.  Analysis of lower limb prosthetic socket interface based on stress and motion measurements.

Authors:  Jinghua Tang; Liudi Jiang; Michael McGrath; Dan Bader; Piotr Laszczak; David Moser; Saeed Zahedi
Journal:  Proc Inst Mech Eng H       Date:  2022-07-12       Impact factor: 1.763

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.