Abstract

Cardiac magnetic resonance imaging and echocardiography are currently regarded as standard modalities for the quantification of left ventricular volumes and ejection fraction. With the recent introduction of dual-source computedtomography (DSCT), the increased temporal resolution of 83 ms should also improve the assessment of cardiac function in CT. The aim of this study was to evaluate the accuracy of DSCT in the assessment of left ventricular functional parameters with cardiac magnetic resonance imaging (MRI) as standard of reference. Fifteen patients (two female, 13 male; mean age 50.8 +/- 19.2 years) underwent CT and MRI examinations on a DSCT (Somatom Definition; Siemens Medical Solutions, Forchheim, Germany) and a 3.0-Tesla MR scanner (Magnetom Trio; Siemens Medical Solutions), respectively. Multiphase axial CT images were analysed with a semiautomatic region growing algorithms (Syngo Circulation; Siemens Medical Solutions) by two independent blinded observers. In MRI, dynamic cine loops of short axis slices were evaluated with semiautomatic contour detection software (ARGUS; Siemens Medical Solutions) independently by two readers. End-systolic volume (ESV), end-diastolic volume (EDV), ejection fraction (EF) and stroke volume (SV) were determined for both modalities, and correlation coefficient, systematic error, limits of agreement and inter-observer variability were assessed. In DSCT, EDV and ESV were 135.8 +/- 41.9 ml and 54.9 +/- 29.6 ml, respectively, compared with 132.1 +/- 40.8 ml EDV and 57.6 +/- 27.3 ml ESV in MRI. Thus, EDV was overestimated by 3.7 ml (limits of agreement -46.1/+53.6), while ESV was underestimated by 2.6 ml (-36.6/+31.4). Mean EF was 61.6 +/- 12.4% in DSCT and 57.9 +/- 9.0% in MRI, resulting in an overestimation of EF by 3.8% with limits of agreement at -14.7 and +22.2%. Rank correlation rho values were 0.81 for EDV (P = 0.0024), 0.79 for ESV (P = 0.0031) and 0.64 for EF (P = 0.0168). The kappa value of inter-observer variability were amounted to 0.85 for EDV, ESV and EF. DSCT offers the possibility to quantify left ventricular function from coronary CT angiography datasets with sufficient diagnostic accuracy, adding to the value of the modality in a comprehensive cardiac assessment. The observed differences in the measured values may be due to different post-processing methods and physiological reactions to contrast material injection without beta-blocker medication.

Entities:  

Mesh:

Year:  2007        PMID: 17909817     DOI: 10.1007/s00330-007-0767-y

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  18 in total

1.  Three-Dimensional Echocardiography: Precision and Accuracy of Left Ventricular Volume Measurement Using Rotational Geometry with Variable Numbers of Slice Resolution.

Authors:  Kazuaki Tanabe; Marek Belohlavek; Decho Jakrapanichakul; Richard Y. Bae; James F. Greenleaf; James B. Seward
Journal:  Echocardiography       Date:  1998-08       Impact factor: 1.724

2.  Multi-detector row CT of left ventricular function with dedicated analysis software versus MR imaging: initial experience.

Authors:  Kai Uwe Juergens; Matthias Grude; David Maintz; Eva Maria Fallenberg; Thomas Wichter; Walter Heindel; Roman Fischbach
Journal:  Radiology       Date:  2003-12-10       Impact factor: 11.105

3.  Dual-source CT cardiac imaging: initial experience.

Authors:  Thorsten R C Johnson; Konstantin Nikolaou; Bernd J Wintersperger; Alexander W Leber; Franz von Ziegler; Carsten Rist; Sonja Buhmann; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-05-13       Impact factor: 5.315

4.  [Dual-source cardiac CT imaging with improved temporal resolution: Impact on image quality and analysis of left ventricular function].

Authors:  Carsten Rist; T R Johnson; A Becker; A W Leber; A Huber; S Busch; C R Becker; M F Reiser; K Nikolaou
Journal:  Radiologe       Date:  2007-04       Impact factor: 0.635

5.  Sixteen-slice spiral CT versus MR imaging for the assessment of left ventricular function in acute myocardial infarction.

Authors:  Andreas H Mahnken; Ralf Koos; Marcus Katoh; Elmar Spuentrup; Petra Busch; Joachim E Wildberger; Harald P Kühl; Rolf W Günther
Journal:  Eur Radiol       Date:  2005-01-29       Impact factor: 5.315

6.  Utility of fast cine magnetic resonance imaging and display for the detection of myocardial ischemia in patients not well suited for second harmonic stress echocardiography.

Authors:  W G Hundley; C A Hamilton; M S Thomas; D M Herrington; T B Salido; D W Kitzman; W C Little; K M Link
Journal:  Circulation       Date:  1999-10-19       Impact factor: 29.690

7.  Assessment of left ventricular function and mass in patients undergoing computed tomography (CT) coronary angiography using 64-detector-row CT: comparison to magnetic resonance imaging.

Authors:  T Schlosser; O K Mohrs; A Magedanz; T Voigtländer; A Schmermund; J Barkhausen
Journal:  Acta Radiol       Date:  2007-02       Impact factor: 1.990

Review 8.  Assessment of cardiac function using multidetector row computed tomography.

Authors:  Sarwar H Orakzai; Raza H Orakzai; Khurram Nasir; Matthew J Budoff
Journal:  J Comput Assist Tomogr       Date:  2006 Jul-Aug       Impact factor: 1.826

9.  Detection of coronary artery stenoses with thin-slice multi-detector row spiral computed tomography and multiplanar reconstruction.

Authors:  Dieter Ropers; Ulrich Baum; Karsten Pohle; Katharina Anders; Stefan Ulzheimer; Bernd Ohnesorge; Christian Schlundt; Werner Bautz; Werner G Daniel; Stephan Achenbach
Journal:  Circulation       Date:  2003-02-11       Impact factor: 29.690

10.  Accuracy of contrast-enhanced cine-MR sequences in the assessment of left ventricular function: comparison with precontrast cine-MR sequences. Results of a bicentric study.

Authors:  Jean-Christophe Lasalarie; Jean-Michel Serfaty; Christophe Carre; David Messika-Zeitoun; Christophe Jeannot; Elisabeth Schouman-Claeys; Jean-Pierre Laissy
Journal:  Eur Radiol       Date:  2007-05-08       Impact factor: 5.315

View more
  28 in total

1.  Automatic vs semi-automatic global cardiac function assessment using 64-row CT.

Authors:  J Greupner; E Zimmermann; B Hamm; M Dewey
Journal:  Br J Radiol       Date:  2011-11-01       Impact factor: 3.039

Review 2.  Novel techniques for assessment of left ventricular systolic function.

Authors:  Sonal Chandra; Hicham Skali; Ron Blankstein
Journal:  Heart Fail Rev       Date:  2011-07       Impact factor: 4.214

3.  Assessment of the coronary venous system in heart failure patients by blood pool agent enhanced whole-heart MRI.

Authors:  Robert Manzke; Ludwig Binner; Axel Bornstedt; Nico Merkle; Anja Lutz; Robert Gradinger; Volker Rasche
Journal:  Eur Radiol       Date:  2010-09-26       Impact factor: 5.315

4.  Functional parameters of the left ventricle: comparison of cardiac MRI and cardiac CT in a large population.

Authors:  A Palumbo; E Maffei; C Martini; G Messalli; S Seitun; R Malagò; A Aldrovandi; E Emiliano; A Cuttone; A Weustink; N Mollet; F Cademartiri
Journal:  Radiol Med       Date:  2010-02-22       Impact factor: 3.469

5.  Evaluation of global left ventricular function assessment by dual-source computed tomography compared with MRI.

Authors:  Pieter A van der Vleuten; Gonda J de Jonge; Daniël D Lubbers; René A Tio; Tineke P Willems; Matthijs Oudkerk; Felix Zijlstra
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

6.  Quantification of left ventricular function and mass in heart transplant recipients using dual-source CT and MRI: initial clinical experience.

Authors:  Gorka Bastarrika; Maria Arraiza; Carlo N De Cecco; Stefano Mastrobuoni; Matias Ubilla; Gregorio Rábago
Journal:  Eur Radiol       Date:  2008-05-20       Impact factor: 5.315

7.  The clinical anatomy and pathology of the human arterial valves: implications for repair or replacement.

Authors:  Michael G Bateman; Alexander J Hill; Jason L Quill; Paul A Iaizzo
Journal:  J Cardiovasc Transl Res       Date:  2013-01-17       Impact factor: 4.132

8.  Assessing cardiac injury in mice with dual energy-microCT, 4D-microCT, and microSPECT imaging after partial heart irradiation.

Authors:  Chang-Lung Lee; Hooney Min; Nicholas Befera; Darin Clark; Yi Qi; Shiva Das; G Allan Johnson; Cristian T Badea; David G Kirsch
Journal:  Int J Radiat Oncol Biol Phys       Date:  2014-03-01       Impact factor: 7.038

9.  Assessment of myocardial fibrosis and coronary arteries in hypertrophic cardiomyopathy using combined arterial and delayed enhanced CT: comparison with MR and coronary angiography.

Authors:  Lei Zhao; Xiaohai Ma; Mark C Delano; Tengyong Jiang; Chen Zhang; Yi Liu; Zhaoqi Zhang
Journal:  Eur Radiol       Date:  2012-10-14       Impact factor: 5.315

10.  Novel phase-based noise reduction strategy for quantification of left ventricular function and mass assessment by cardiac CT: comparison with cardiac magnetic resonance.

Authors:  Bryan Wai; Wai-Ee Thai; Heather Brown; Quynh A Truong
Journal:  Eur J Radiol       Date:  2013-03-20       Impact factor: 3.528

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.