Literature DB >> 11175081

Three-Dimensional Echocardiography: Precision and Accuracy of Left Ventricular Volume Measurement Using Rotational Geometry with Variable Numbers of Slice Resolution.

Kazuaki Tanabe1, Marek Belohlavek, Decho Jakrapanichakul, Richard Y. Bae, James F. Greenleaf, James B. Seward.   

Abstract

We developed a new, rapid (6 seconds) acquisition technique allowing collection of approximately six through nine apical rotational tomograms for three-dimensional (3-D) echocardiography. To justify an appropriate sampling density for precise and accurate measurement of chamber volumes in left ventricles with complicated shape, we designed a validation study in vitro using six canine heart specimens with irregular, asymmetric left ventricles with known volumes (28.5 to 104.3 ml; mean, 71.2 ml). The number of equally spaced slices were incrementally deleted from the original high resolution scans (48 slices) to 2 slices in 3-D reconstruction. We created subgroups of 48- and 36-, 24- and 16-, 12- and 8-, 6- and 4-, and 3- and 2-component slices to compare left ventricular (LV) volumes measured in 3-D images with different slice resolution with the reference standard measured in the specimen. The accuracy and precision of LV volume were relatively constant in the subgroup of 4- and 6- through 36- and 48-component slices. When the subgroup with 6- and 4-component slices was used, the correlation was r = 0.991, P < 0.0001, root-mean-square percent error of 5.0%, bias of 0.5 +/- 3.7 ml, and interobserver variability of 5.0%. With the reduction in component slices equal or less than three, the accuracy decreased significantly (root-mean-square percent error = 8.1% and bias = -2.0 +/- 5.7 ml) compared with higher slice resolutions. This study demonstrated that 3-D echocardiography using apical rotational techniques can accurately quantify LV volume in the canine heart specimens with irregular shapes with as few as 4-6 axial slices. The rapid 3-D acquisition technique is therefore anticipated to yield precise and accurate LV volumetry.

Entities:  

Year:  1998        PMID: 11175081     DOI: 10.1111/j.1540-8175.1998.tb00649.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  4 in total

1.  Quantitative assessment of left ventricular function with dual-source CT in comparison to cardiac magnetic resonance imaging: initial findings.

Authors:  S Busch; T R C Johnson; B J Wintersperger; N Minaifar; A Bhargava; C Rist; M F Reiser; C Becker; K Nikolaou
Journal:  Eur Radiol       Date:  2007-10-02       Impact factor: 5.315

2.  Accuracy of three-dimensional echocardiography in patients with prior anteroseptal myocardial infarction.

Authors:  Yoshiaki Maruyama; Kentaro Toyama; Shunichi Sato; Nobuyuki Masaki; Masato Kirimura; Nobuo Yoshimoto
Journal:  J Echocardiogr       Date:  2009-01-14

Review 3.  Incorporating three-dimensional echocardiography into clinical practice.

Authors:  Kazuaki Tanabe; Kazuto Yamaguchi
Journal:  J Echocardiogr       Date:  2019-09-11

4.  Early change in left atrial function in patients treated with anthracyclines assessed by real-time three-dimensional echocardiography.

Authors:  Jing Shi; Ye Guo; Leilei Cheng; Feiyan Song; Xianhong Shu
Journal:  Sci Rep       Date:  2016-05-05       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.