Literature DB >> 17909791

CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution.

Riikka Lautamäki1, Tracy L Y Brown, Jennifer Merrill, Frank M Bengel.   

Abstract

PURPOSE: Misalignment of low-dose-CT used for attenuation correction (AC) may cause artifacts in cardiac-PET-CT. The aim was to evaluate incidence and severity of misalignment and its quantitative effects on regional myocardial (82)Rb-distribution.
METHODS: Rest/dipyridamole (82)Rb-perfusion-PET-CT studies of 92 consecutive patients were analyzed for misalignment. Two different scanning protocols were employed: the first 57 patients had separate CTs for rest and stress PET. The following 35 patients had one CT at rest, used for AC of rest and stress PET. Misalignment was visually scored on a five-point scale (0 = no, 1 = minimal, 2 = mild, 3 = moderate, and 4 = severe). In five representative patients with normal perfusion and low probability of disease, 95 polarmaps were created by shifting CT vs PET prior to reconstruction of attenuation-corrected data sets using dedicated software (three dimensions of space; magnitude of shifts, 5, 10, 14 mm).
RESULTS: PET/CT -misalignment was detected in 60% of rest and 67% of stress studies. Alignment for rest was better than that for stress (0.7 +/- 0.7 vs 1.0 +/- 0.9, P = 0.03). Comparison of the two protocols revealed no effect on the alignment of the stress study (1.0 +/- 0.9 vs 1.0 +/- 0.9, P = 0.9). Quantitatively, the largest individual effect of any artificial misalignment was a 25% reduction of relative (82)Rb uptake. With a shift of 1 cm, the largest effect in an individual was a 19% decrease. Anterior wall was most frequently influenced by misalignment, but changes of uptake also occurred in all other segments.
CONCLUSIONS: Misalignment between CT and PET in cardiac-PET-CT influences regional tracer distribution in multiple segments. Repeated CT imaging after dipyridamole does not improve alignment. These results emphasize the need for strategies to improve coregistration in clinical imaging protocols.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17909791     DOI: 10.1007/s00259-007-0607-y

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  22 in total

1.  Dual-modality PET/CT imaging: the effect of respiratory motion on combined image quality in clinical oncology.

Authors:  Thomas Beyer; Gerald Antoch; Todd Blodgett; Lutz F Freudenberg; Tim Akhurst; Stephan Mueller
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-02-12       Impact factor: 9.236

2.  Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT.

Authors:  Medhat M Osman; Christian Cohade; Yuji Nakamoto; Richard L Wahl
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-01-21       Impact factor: 9.236

3.  Clinically significant inaccurate localization of lesions with PET/CT: frequency in 300 patients.

Authors:  Medhat M Osman; Christian Cohade; Yuji Nakamoto; Laura T Marshall; Jeff P Leal; Richard L Wahl
Journal:  J Nucl Med       Date:  2003-02       Impact factor: 10.057

4.  Attenuation correction of PET images with respiration-averaged CT images in PET/CT.

Authors:  Tinsu Pan; Osama Mawlawi; Sadek A Nehmeh; Yusuf E Erdi; Dershan Luo; Hui H Liu; Richard Castillo; Radhe Mohan; Zhongxing Liao; H A Macapinlac
Journal:  J Nucl Med       Date:  2005-09       Impact factor: 10.057

5.  Myocardial viability testing and the effect of early intervention in patients with advanced left ventricular systolic dysfunction.

Authors:  Khaldoun G Tarakji; Richard Brunken; Patrick M McCarthy; M Obadah Al-Chekakie; Ahmed Abdel-Latif; Claire E Pothier; Eugene H Blackstone; Michael S Lauer
Journal:  Circulation       Date:  2006-01-03       Impact factor: 29.690

6.  Attenuation correction in myocardial perfusion SPECT/CT: effects of misregistration and value of reregistration.

Authors:  Sibyll Goetze; Tracy L Brown; William C Lavely; Zhe Zhang; Frank M Bengel
Journal:  J Nucl Med       Date:  2007-06-15       Impact factor: 10.057

7.  Effects of misalignment between transmission and emission scans on attenuation-corrected cardiac SPECT.

Authors:  I Matsunari; G Böning; S I Ziegler; I Kosa; S G Nekolla; E P Ficaro; M Schwaiger
Journal:  J Nucl Med       Date:  1998-03       Impact factor: 10.057

8.  Four-dimensional (4D) PET/CT imaging of the thorax.

Authors:  S A Nehmeh; Y E Erdi; T Pan; A Pevsner; K E Rosenzweig; E Yorke; G S Mageras; H Schoder; Phil Vernon; O Squire; H Mostafavi; S M Larson; J L Humm
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

9.  Diagnostic accuracy of rest/stress ECG-gated Rb-82 myocardial perfusion PET: comparison with ECG-gated Tc-99m sestamibi SPECT.

Authors:  Timothy M Bateman; Gary V Heller; A Iain McGhie; John D Friedman; James A Case; Jan R Bryngelson; Ginger K Hertenstein; Kelly L Moutray; Kimberly Reid; S James Cullom
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

10.  Diagnostic accuracy of rubidium-82 myocardial perfusion imaging with hybrid positron emission tomography/computed tomography in the detection of coronary artery disease.

Authors:  Uchechukwu K Sampson; Sharmila Dorbala; Atul Limaye; Raymond Kwong; Marcelo F Di Carli
Journal:  J Am Coll Cardiol       Date:  2007-02-26       Impact factor: 24.094

View more
  28 in total

1.  Attenuation-emission alignment in cardiac PET/CT based on consistency conditions.

Authors:  Adam M Alessio; Paul E Kinahan; Kyle M Champley; James H Caldwell
Journal:  Med Phys       Date:  2010-03       Impact factor: 4.071

2.  Is metal artefact reduction mandatory in cardiac PET/CT imaging in the presence of pacemaker and implantable cardioverter defibrillator leads?

Authors:  Pardis Ghafarian; S M R Aghamiri; Mohammad R Ay; Arman Rahmim; Thomas H Schindler; Osman Ratib; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-10-20       Impact factor: 9.236

3.  ⁸²Rb PET myocardial perfusion imaging is superior to ⁹⁹mTc-labelled agent SPECT in patients with known or suspected coronary artery disease.

Authors:  Albert Flotats; Paco E Bravo; Kenji Fukushima; Muhammad A Chaudhry; Jennifer Merrill; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-05-31       Impact factor: 9.236

Review 4.  Clinical use of quantitative cardiac perfusion PET: rationale, modalities and possible indications. Position paper of the Cardiovascular Committee of the European Association of Nuclear Medicine (EANM).

Authors:  Roberto Sciagrà; Alessandro Passeri; Jan Bucerius; Hein J Verberne; Riemer H J A Slart; Oliver Lindner; Alessia Gimelli; Fabien Hyafil; Denis Agostini; Christopher Übleis; Marcus Hacker
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-02-05       Impact factor: 9.236

Review 5.  Facts and figures on CAD assessment with SPECT and PET-CT.

Authors:  Giovanni Lucignani
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-02       Impact factor: 9.236

Review 6.  Present and future of clinical cardiovascular PET imaging in Europe--a position statement by the European Council of Nuclear Cardiology (ECNC).

Authors:  D Le Guludec; R Lautamäki; J Knuuti; J J Bax; F M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-06-26       Impact factor: 9.236

Review 7.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

8.  Washout of ⁸²Rb as a marker of impaired tissue integrity, obtained by list-mode cardiac PET/CT: relationship with perfusion/metabolism patterns of myocardial viability.

Authors:  David T Chien; Paco Bravo; Takahiro Higuchi; Jennifer Merrill; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2011-04-29       Impact factor: 9.236

9.  Lowering radiation dose for integrated assessment of coronary morphology and physiology: first experience with step-and-shoot CT angiography in a rubidium 82 PET-CT protocol.

Authors:  Mehrbod Javadi; Mahadevappa Mahesh; Gerald McBride; Corina Voicu; William Epley; Jennifer Merrill; Frank M Bengel
Journal:  J Nucl Cardiol       Date:  2008-09-12       Impact factor: 5.952

10.  Rubidium-82 PET-CT for quantitative assessment of myocardial blood flow: validation in a canine model of coronary artery stenosis.

Authors:  Riikka Lautamäki; Richard T George; Kakuya Kitagawa; Takahiro Higuchi; Jennifer Merrill; Corina Voicu; Anthony DiPaula; Stephan G Nekolla; João A C Lima; Albert C Lardo; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-11-05       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.