Respiratory motion artifacts on PET emission images obtained using CT attenuation correction on PET-CT.

Medhat M Osman1, Christian Cohade, Yuji Nakamoto, Richard L Wahl.   

Abstract

PET-CT scanners allow generation of transmission maps from CT. The use of CT attenuation correction (CTAC) instead of germanium-68 attenuation correction (Ge AC) might be expected to cause artifacts on reconstructed emission images if differences in respiratory status exist between the two methods of attenuation correction. The aim of this study was to evaluate for possible respiratory motion artifacts (RMA) in PET images attenuation corrected with CT from PET-CT in clinical patients. PET-CT scans were performed using a Discovery LS PET-CT system in 50 consecutive patients (23 males, 27 females; mean age 58.2 years) with known or suspected malignancy. Both CTAC and Ge AC transmission data obtained during free tidal breathing were used to correct PET emission images. Cold artifacts at the interface of the lungs and diaphragm, believed to be due to respiratory motion (RMA), that were seen on CTAC images but not on the Ge AC images were evaluated qualitatively on a four-point scale (0, no artifact; 1, mild artifact; 2, moderate artifact; 3, severe artifact). RMA was also measured for height. Curvilinear cold artifacts paralleling the dome of the diaphragm at the lung/diaphragm interface were noted on 84% of PET-CT image acquisitions and were not seen on the (68)Ge-corrected images; however, these artifacts were infrequently severe. In conclusion, RMA of varying magnitude were noted in most of our patients as a curvilinear cold area at the lung/diaphragm interface, but were not diagnostically problematic in these patients.

Entities:  

Mesh:

Year:  2003        PMID: 12536242     DOI: 10.1007/s00259-002-1024-x

Source DB:  PubMed          Journal:  Eur J Nucl Med Mol Imaging        ISSN: 1619-7070            Impact factor:   9.236


  5 in total

1.  Hybrid PET/CT machines: optimized PET machines for the new millennium?

Authors:  T Akhurst; R Chisin
Journal:  J Nucl Med       Date:  2000-05       Impact factor: 10.057

2.  Attenuation correction for a combined 3D PET/CT scanner.

Authors:  P E Kinahan; D W Townsend; T Beyer; D Sashin
Journal:  Med Phys       Date:  1998-10       Impact factor: 4.071

3.  PET-CT image co-registration in the thorax: influence of respiration.

Authors:  Gerhard W Goerres; Ehab Kamel; Thai-Nia H Heidelberg; Michael R Schwitter; Cyrill Burger; Gustav K von Schulthess
Journal:  Eur J Nucl Med Mol Imaging       Date:  2002-03       Impact factor: 9.236

4.  A combined PET/CT scanner for clinical oncology.

Authors:  T Beyer; D W Townsend; T Brun; P E Kinahan; M Charron; R Roddy; J Jerin; J Young; L Byars; R Nutt
Journal:  J Nucl Med       Date:  2000-08       Impact factor: 10.057

5.  Effect of respiratory gating on quantifying PET images of lung cancer.

Authors:  Sadek A Nehmeh; Yusuf E Erdi; Clifton C Ling; Kenneth E Rosenzweig; Heiko Schoder; Steve M Larson; Homer A Macapinlac; Olivia D Squire; John L Humm
Journal:  J Nucl Med       Date:  2002-07       Impact factor: 10.057

  5 in total
  56 in total

Review 1.  PET/CT: a new imaging technology in nuclear medicine.

Authors:  Heiko Schöder; Yusuf E Erdi; Steven M Larson; Henry W D Yeung
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-09-05       Impact factor: 9.236

2.  The new-generation positron emission tomography/computed tomography scanners: implications for cardiac imaging.

Authors:  Stephen L Bacharach
Journal:  J Nucl Cardiol       Date:  2004 Jul-Aug       Impact factor: 5.952

3.  Comparative assessment of energy-mapping approaches in CT-based attenuation correction for PET.

Authors:  Mohammad R Ay; Maryam Shirmohammad; Saeed Sarkar; Arman Rahmim; Habib Zaidi
Journal:  Mol Imaging Biol       Date:  2011-02       Impact factor: 3.488

4.  Improvements in PET Image Quality in Time of Flight (TOF) Simultaneous PET/MRI.

Authors:  Ryogo Minamimoto; Craig Levin; Mehran Jamali; Dawn Holley; Amir Barkhodari; Greg Zaharchuk; Andrei Iagaru
Journal:  Mol Imaging Biol       Date:  2016-10       Impact factor: 3.488

5.  Correlation between respiration-induced thoracic expansion and a shift of central structures.

Authors:  M Weckesser; L Stegger; K U Juergens; D Wormanns; W Heindel; O Schober
Journal:  Eur Radiol       Date:  2005-12-21       Impact factor: 5.315

6.  Assessment of errors caused by X-ray scatter and use of contrast medium when using CT-based attenuation correction in PET.

Authors:  Mohammad Reza Ay; Habib Zaidi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2006-04-19       Impact factor: 9.236

7.  How serious a problem for myocardial perfusion assessment is moderate misregistration between SPECT and CT?

Authors:  Kenneth J Nichols
Journal:  J Nucl Cardiol       Date:  2007-04       Impact factor: 5.952

8.  CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution.

Authors:  Riikka Lautamäki; Tracy L Y Brown; Jennifer Merrill; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-02       Impact factor: 9.236

9.  Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

Authors:  Sarah J McQuaid; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-25       Impact factor: 9.236

10.  Respiratory-gated PET/CT versus delayed images for the quantitative evaluation of lower pulmonary and hepatic lesions.

Authors:  Abdel K Tahari; Martin A Lodge; Richard L Wahl
Journal:  J Med Imaging Radiat Oncol       Date:  2014-01-20       Impact factor: 1.735

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.