UNLABELLED: The accuracy of myocardial perfusion SPECT improves with attenuation correction. Algorithms for attenuation correction in hybrid SPECT/CT systems have the potential for misregistration of emission and transmission scans because CT and SPECT are obtained sequentially. Misregistration will influence regional tracer distribution and may reduce diagnostic accuracy. This study focused on the role of misregistration in cardiac SPECT/CT and the performance of a software-based approach for reregistration.
METHODS: We included 105 consecutive patients who underwent clinical myocardial perfusion imaging on a SPECT/CT system. Images were quantitatively assessed for misregistration using fusion software. Results were recorded in millimeters in the x-, y-, and z-axes. Regional tracer uptake in 6 segments (anterior, septal, inferior, lateral, anteroapical, and inferoapical) for noncorrected and attenuation-corrected images before and after reregistration was obtained from polar maps. To determine the relative influence of misregistration, we correlated individual differences between noncorrected and attenuation-corrected images, as well as between attenuation-corrected images before and after reregistration, with the degree of misregistration in a multivariate analysis including additional clinical variables such as sex and body weight.
RESULTS: The difference in regional radiotracer uptake was significant between noncorrected and attenuation-corrected images in all 6 segments and was most pronounced in the inferior wall. On multivariate analysis, misregistration contributed significantly to changes in radiotracer distribution in the anterior (P = 0.038), septal (P = 0.011), and inferior (P = 0.006) segments. The mean misregistration was 8.6 +/- 3.8 mm (1.25 +/- 0.55 pixel). Misregistration of one or more pixels was observed in 64% of studies. Reregistration of misalignment significantly affected regional radiotracer distribution in the segments shown to be influenced by misregistration.
CONCLUSION: Misregistration occurs with SPECT/CT systems and influences regional tracer distribution on attenuation-corrected myocardial images. Reregistration of misaligned studies may be a useful tool for correction. The impact of this strategy on the diagnostic and prognostic accuracy of cardiac hybrid imaging needs to be determined.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17574985     DOI: 10.2967/jnumed.107.040535

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  29 in total

1.  ⁸²Rb PET myocardial perfusion imaging is superior to ⁹⁹mTc-labelled agent SPECT in patients with known or suspected coronary artery disease.

Authors:  Albert Flotats; Paco E Bravo; Kenji Fukushima; Muhammad A Chaudhry; Jennifer Merrill; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2012-05-31       Impact factor: 9.236

2.  Impact of respiratory motion correction on SPECT myocardial perfusion imaging using a mechanically moving phantom assembly with variable cardiac defects.

Authors:  Irene Polycarpou; Isabelle Chrysanthou-Baustert; Ourania Demetriadou; Yiannis Parpottas; Christoforos Panagidis; Paul K Marsden; Lefteris Livieratos
Journal:  J Nucl Cardiol       Date:  2015-12-16       Impact factor: 5.952

3.  Characterization of attenuation and respiratory motion artifacts and their influence on SPECT MP image evaluation using a dynamic phantom assembly with variable cardiac defects.

Authors:  Isabelle Chrysanthou-Baustert; Irene Polycarpou; Ourania Demetriadou; Lefteris Livieratos; Antonis Lontos; Antonis Antoniou; Stelios Christofides; Charalambos Yiannakkaras; Demetris Kaolis; Christoforos Panagidis; Paul K Marsden; Yiannis Parpottas
Journal:  J Nucl Cardiol       Date:  2016-02-04       Impact factor: 5.952

4.  Evaluating the effectiveness of a single CT method for attenuation correction in stress-rest myocardial perfusion imaging with thallium-201 chloride SPECT.

Authors:  Mitsuha Fukami; Kiyoshi Tamura; Yuya Nakamura; Syoichi Nakatsukasa; Masayuki Sasaki
Journal:  Radiol Phys Technol       Date:  2019-11-25

5.  Effects of patient movement on measurements of myocardial blood flow and viability in resting ¹⁵O-water PET studies.

Authors:  Kazuhiro Koshino; Hiroshi Watabe; Junichiro Enmi; Yoshiyuki Hirano; Tsutomu Zeniya; Shinji Hasegawa; Takuya Hayashi; Shigeru Miyagawa; Yoshiki Sawa; Jun Hatazawa; Hidehiro Iida
Journal:  J Nucl Cardiol       Date:  2012-06       Impact factor: 5.952

6.  CT-based attenuation correction in (82)Rb-myocardial perfusion PET-CT: incidence of misalignment and effect on regional tracer distribution.

Authors:  Riikka Lautamäki; Tracy L Y Brown; Jennifer Merrill; Frank M Bengel
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-10-02       Impact factor: 9.236

7.  Respiratory motion handling is mandatory to accomplish the high-resolution PET destiny.

Authors:  Doumit Daou
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-09-12       Impact factor: 9.236

Review 8.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 9.  Current state of hybrid imaging: attenuation correction and fusion.

Authors:  Jonathon A Nye; Tracy L Faber
Journal:  J Nucl Cardiol       Date:  2011-05-07       Impact factor: 5.952

Review 10.  Morphology supporting function: attenuation correction for SPECT/CT, PET/CT, and PET/MR imaging.

Authors:  Tzu C Lee; Adam M Alessio; Robert M Miyaoka; Paul E Kinahan
Journal:  Q J Nucl Med Mol Imaging       Date:  2015-11-17       Impact factor: 2.346