Literature DB >> 1772917

An improved phantom for quality control of laser scanner digitizers in picture archival and communications systems.

E J Halpern1, P D Esser.   

Abstract

Various quality control (QC) procedures may be used to evaluate image quality for picture archival and communications (PACS) systems. A standard PACS QC protocol applied on a regular basis is desirable to ensure optimal diagnostic performance. We describe a QC phantom designed especially to test PACS systems that acquire images by digitizing x-ray films. The phantom is a sheet of x-ray film upon which a digital test pattern is printed. Multiple parameters of image quality are tested, including resolution, contrast, gray scale, geometric distortion, and noise. Individual test patterns are incorporated to detect specific artifacts of laser scanner digitizers. As part of a regular QC protocol, the phantom provides an objective measurement of change in digital image quality over time, as well as an objective means for comparison with other systems.

Mesh:

Year:  1991        PMID: 1772917     DOI: 10.1007/bf03173906

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  5 in total

1.  Performance tests and quality control of cathode ray tube displays.

Authors:  H Roehrig; H Blume; T L Ji; M Browne
Journal:  J Digit Imaging       Date:  1990-08       Impact factor: 4.056

2.  Contrast information of digital imaging in laser film digitizer and display monitor.

Authors:  S C Lo; J W Gaskill; S K Mun; B H Krasner
Journal:  J Digit Imaging       Date:  1990-05       Impact factor: 4.056

3.  A quality-control phantom for digitization of radiographs.

Authors:  E J Halpern; P D Esser; E L Nickoloff; P O Alderson
Journal:  J Digit Imaging       Date:  1990-02       Impact factor: 4.056

4.  Performance characteristics of a laser scanner and laser printer system for radiological imaging.

Authors:  S C Lo; R K Taira; N J Mankovich; H K Huang; H Takeuchi
Journal:  Comput Radiol       Date:  1986 Sep-Oct

5.  Test pattern for video displays and hard-copy cameras.

Authors:  J E Gray; K G Lisk; D H Haddick; J H Harshbarger; A Oosterhof; R Schwenker
Journal:  Radiology       Date:  1985-02       Impact factor: 11.105

  5 in total
  3 in total

1.  Quality assurance of picture archiving communication systems with laser film digitizers.

Authors:  P D Esser; E J Halpern; E S Amis
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

2.  The laser film digitizer: density, contrast, and resolution.

Authors:  T N Teslow
Journal:  J Digit Imaging       Date:  1997-08       Impact factor: 4.056

3.  A test pattern for quality control of laser scanner and charge-coupled device film digitizers.

Authors:  E J Halpern
Journal:  J Digit Imaging       Date:  1995-02       Impact factor: 4.056

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.