Literature DB >> 1772918

Quality assurance of picture archiving communication systems with laser film digitizers.

P D Esser1, E J Halpern, E S Amis.   

Abstract

A comprehensive quality assurance (QA) program should be implemented for all teleradiology and picture archival and communications (PACS) systems. In this report, we summarize our QA experience with a teleradiology system that includes a laser digitizer for x-ray film. A key component required for the evaluation of laser film scanners is an appropriate test pattern; digitizers should be evaluated with enhanced test patterns specifically designed for this purpose. The phantom pattern should measure high-contrast resolution, low-contrast discrimination, gray scale linearity, geometric distortion, and noise. In addition, a uniformly exposed sheet of film (approximately 0.3 optical density) serves as a good phantom for testing screen nonuniformities of viewing station monitors. It is also suggested that clinical images should be included in a QA program. Finally, it is recommended that any discrepancies in the interpretation of teleradiology images should be monitored and investigated.

Mesh:

Year:  1991        PMID: 1772918     DOI: 10.1007/bf03173907

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  4 in total

1.  Contrast information of digital imaging in laser film digitizer and display monitor.

Authors:  S C Lo; J W Gaskill; S K Mun; B H Krasner
Journal:  J Digit Imaging       Date:  1990-05       Impact factor: 4.056

2.  An improved phantom for quality control of laser scanner digitizers in picture archival and communications systems.

Authors:  E J Halpern; P D Esser
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

3.  Performance characteristics of a laser scanner and laser printer system for radiological imaging.

Authors:  S C Lo; R K Taira; N J Mankovich; H K Huang; H Takeuchi
Journal:  Comput Radiol       Date:  1986 Sep-Oct

4.  Test pattern for video displays and hard-copy cameras.

Authors:  J E Gray; K G Lisk; D H Haddick; J H Harshbarger; A Oosterhof; R Schwenker
Journal:  Radiology       Date:  1985-02       Impact factor: 11.105

  4 in total
  1 in total

1.  Utilization of DICOM GSDF to modify lookup tables for images acquired on film digitizers.

Authors:  David M Jones
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

  1 in total