Contrast information of digital imaging in laser film digitizer and display monitor.

S C Lo1, J W Gaskill, S K Mun, B H Krasner.   

Abstract

A 10-bit or 12-bit gray scale is provided in commercial laser film digitizers. The true contrast resolution on the digitized image within a laser spot area of 200 microns in diameter is limited by both the quantum mottle and instrumentation noise. In this report, we investigated the mean value, standard deviation, and adjacent pixel correlation coefficient on a calibrated step wedge film with two laser digitizers. The results were disappointing, because we found that the evaluated contrast information is inferior to the manufacturers' specifications. On the output side, the brightnesses of different gray levels from a clinical monitor were measured with a narrow angle luminance probe and evaluated by a brief human perception study. In addition, the implications for teleradiology applications are discussed.

Entities:  

Mesh:

Year:  1990        PMID: 2092810     DOI: 10.1007/BF03170571

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  2 in total

1.  Noise impact on error-free image compression.

Authors:  S B Lo; B Krasner; S K Mun
Journal:  IEEE Trans Med Imaging       Date:  1990       Impact factor: 10.048

2.  Performance characteristics of a laser scanner and laser printer system for radiological imaging.

Authors:  S C Lo; R K Taira; N J Mankovich; H K Huang; H Takeuchi
Journal:  Comput Radiol       Date:  1986 Sep-Oct
  2 in total
  6 in total

Review 1.  Literature review: picture archiving and communication system.

Authors:  U P Schmiedl; A H Rowberg
Journal:  J Digit Imaging       Date:  1990-11       Impact factor: 4.056

2.  Utilization of DICOM GSDF to modify lookup tables for images acquired on film digitizers.

Authors:  David M Jones
Journal:  J Digit Imaging       Date:  2006-06       Impact factor: 4.056

Review 3.  High-resolution digital teleradiology: a perspective.

Authors:  G R Kuduvalli; R M Rangayyan; J E Desautels
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

4.  Quality assurance of picture archiving communication systems with laser film digitizers.

Authors:  P D Esser; E J Halpern; E S Amis
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

5.  An improved phantom for quality control of laser scanner digitizers in picture archival and communications systems.

Authors:  E J Halpern; P D Esser
Journal:  J Digit Imaging       Date:  1991-11       Impact factor: 4.056

Review 6.  Teleradiology/telepathology requirements and implementation.

Authors:  S K Mun; A M Elsayed; W G Tohme; Y C Wu
Journal:  J Med Syst       Date:  1995-04       Impact factor: 4.460

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.