Literature DB >> 17724195

Dynamic analysis of dark-light changes of the anterior chamber angle with anterior segment OCT.

Christopher Kai-shun Leung1, Carol Yim Lui Cheung, Haitao Li, Syril Dorairaj, Cedric Ka Fai Yiu, Amy Lee Wong, Jeffrey Liebmann, Robert Ritch, Robert Weinreb, Dennis Shun Chiu Lam.   

Abstract

PURPOSE: To describe the use of anterior segment optical coherence tomography (OCT) in studying the dynamic dark-light changes of the anterior chamber angle.
METHODS: Thirty-seven normal subjects with open angles on dark-room gonioscopy and 18 subjects with narrow angles were analyzed. The dynamic dark-light changes of the anterior-chamber angle were captured with real-time video recording. The angle opening distance (AOD500) and trabecular iris space area (TISA500) of the nasal angle and the pupil diameter in each of the representative serial images were measured. Linear regression analysis was performed to investigate the association between AOD500/TISA500 and pupil diameter. Demographic and biometry measurements associated with the AOD difference (AOD500((light)) - AOD500((dark))) and TISA difference (TISA500((light)) - TISA500((dark))) were analyzed with univariate and multivariate regression models.
RESULTS: The AOD500/TISA500 measured in the light in the open-angle and the narrow-angle groups were 694 +/- 330 microm/0.24 +/- 0.10 mm(2) and 265 +/- 78 microm/0.10 +/- 0.03 mm(2), respectively. These values were significantly greater than the AOD500/TISA500 measured in the dark (492 +/- 265 microm/0.16 +/- 0.08 mm(2) and 119 +/- 82 microm/0.05 +/- 0.04 mm(2), respectively, all with P < 0.001). The ranges of the AOD/TISA difference were 13 to 817 microm/0.011 to 0.154 mm(2), with an average of 180 microm/0.073 mm(2). Multivariate regression analysis identified a positive correlation between anterior chamber depth and the AOD/TISA difference. Fifty eyes showed significant correlations between AOD/TISA and pupil diameter, whereas one eye showed no association. Four eyes in the narrow angle group developed appositional angle closure in the dark.
CONCLUSIONS: The dynamic dark-light changes of the anterior chamber angle can be imaged and analyzed with anterior segment OCT. Although the angle width generally decreased linearly with increasing pupil diameter, the differences of the angle width measured in the dark and in the light varied substantially among individuals.

Mesh:

Year:  2007        PMID: 17724195     DOI: 10.1167/iovs.07-0010

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  29 in total

1.  Pupil dynamics in Chinese subjects with angle closure.

Authors:  Ce Zheng; Carol Y Cheung; Arun Narayanaswamy; Sim-Heng Ong; Shamira A Perera; Mani Baskaran; Paul T Chew; David S Friedman; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-01-31       Impact factor: 3.117

2.  Determinants of pupil diameters and pupil dynamics in an adult Chinese population.

Authors:  Ce Zheng; John Mark S de Leon; Carol Y Cheung; Arun K Narayanaswamy; Sim-Heng Ong; Clement W Tan; Paul T Chew; Shamira A Perera; Tien Y Wong; Tin Aung
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2016-01-25       Impact factor: 3.117

3.  Anterior chamber angle imaging with optical coherence tomography.

Authors:  C K-S Leung; R N Weinreb
Journal:  Eye (Lond)       Date:  2011-01-14       Impact factor: 3.775

4.  Light-dark changes in iris thickness and anterior chamber angle width in eyes with occludable angles.

Authors:  Fumitaka Hirose; Masayuki Hata; Shin-ichiro Ito; Takaaki Matsuki; Yasuo Kurimoto
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-05-21       Impact factor: 3.117

5.  Correlation between Intraocular Pressure and Angle Configuration Measured by OCT: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Bruce Burkemper; Juan Pablo Lewinger; Xuejuan Jiang; Anmol A Pardeshi; Grace Richter; Mina Torres; Roberta McKean-Cowdin; Rohit Varma
Journal:  Ophthalmol Glaucoma       Date:  2018-09-29

6.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

7.  Association of Angle Width With Progression of Normal-Tension Glaucoma: A Minimum 7-Year Follow-up Study.

Authors:  Ahnul Ha; Young Kook Kim; Jin Wook Jeoung; Dong Myung Kim; Ki Ho Park
Journal:  JAMA Ophthalmol       Date:  2019-01-01       Impact factor: 7.389

8.  Reproducibility and Agreement of Anterior Segment Parameter Measurements Obtained Using the CASIA2 and Spectralis OCT2 Optical Coherence Tomography Devices.

Authors:  Benjamin Y Xu; Derek D Mai; Rafaella C Penteado; Luke Saunders; Robert N Weinreb
Journal:  J Glaucoma       Date:  2017-11       Impact factor: 2.503

9.  Changes in anterior chamber configuration after cataract surgery as measured by anterior segment optical coherence tomography.

Authors:  Martha Kim; Ki Ho Park; Tae-Woo Kim; Dong Myung Kim
Journal:  Korean J Ophthalmol       Date:  2011-03-11

10.  Contribution of different anatomical and physiologic factors to iris contour and anterior chamber angle changes during pupil dilation: theoretical analysis.

Authors:  Sara Jouzdani; Rouzbeh Amini; Victor H Barocas
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-04-26       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.