Literature DB >> 23482467

Contribution of different anatomical and physiologic factors to iris contour and anterior chamber angle changes during pupil dilation: theoretical analysis.

Sara Jouzdani1, Rouzbeh Amini, Victor H Barocas.   

Abstract

PURPOSE: To investigate the contribution of three anatomical and physiologic factors (dilator thickness, dynamic pupillary block, and iris compressibility) to changes in iris configuration and anterior chamber angle during pupil dilation.
METHODS: A MATHEMATICAL MODEL OF THE ANTERIOR SEGMENT BASED ON THE AVERAGE VALUES OF OCULAR DIMENSIONS WAS DEVELOPED TO SIMULATE PUPIL DILATION. TO CHANGE THE PUPIL DIAMETER FROM 3.0 TO 5.4 MM IN 10 SECONDS, ACTIVE DILATOR CONTRACTION WAS APPLIED BY IMPOSING STRESS IN THE DILATOR REGION. THREE SETS OF PARAMETERS WERE VARIED IN THE SIMULATIONS: (1) a thin (4 μm, 1% of full thickness) versus a thick dilator (covering the full thickness iris) to quantify the effects of dilator anatomy, (2) in the presence (+PB) versus absence of pupillary block (-PB) to quantify the effect of dynamic motion of aqueous humor from the posterior to the anterior chamber, and (3) a compressible versus an incompressible iris to quantify the effects of iris volume change. Changes in the apparent iris-lens contact and angle open distance (AOD500) were calculated for each case.
RESULTS: The thin case predicted a significant increase (average 700%) in iris curvature compared with the thick case (average 70%), showing that the anatomy of dilator plays an important role in iris deformation during dilation. In the presence of pupillary block (+PB), AOD500 decreased 25% and 36% for the compressible and incompressible iris, respectively.
CONCLUSIONS: Iris bowing during dilation was driven primarily by posterior location of the dilator muscle and by dynamic pupillary block, but the effect of pupillary block was not as large as that of the dilator anatomy according to the quantified values of AOD500. Incompressibility of the iris, in contrast, had a relatively small effect on iris curvature but a large effect on AOD500; thus, we conclude that all three effects are important.

Entities:  

Mesh:

Year:  2013        PMID: 23482467      PMCID: PMC3638663          DOI: 10.1167/iovs.12-10748

Source DB:  PubMed          Journal:  Invest Ophthalmol Vis Sci        ISSN: 0146-0404            Impact factor:   4.799


  28 in total

1.  Modeling passive mechanical interaction between aqueous humor and iris.

Authors:  J J Heys; V H Barocas; M J Taravella
Journal:  J Biomech Eng       Date:  2001-12       Impact factor: 2.097

2.  Computational evaluation of the role of accommodation in pigmentary glaucoma.

Authors:  Jeffrey J Heys; Victor H Barocas
Journal:  Invest Ophthalmol Vis Sci       Date:  2002-03       Impact factor: 4.799

3.  Active iris mechanics and pupillary block: steady-state analysis and comparison with anatomical risk factors.

Authors:  Eric C Huang; Victor H Barocas
Journal:  Ann Biomed Eng       Date:  2004-09       Impact factor: 3.934

4.  Ultrasound biomicroscopic quantitative analysis of light-dark changes associated with pupillary block.

Authors:  E K Woo; C J Pavlin; A Slomovic; N Taback; Y M Buys
Journal:  Am J Ophthalmol       Date:  1999-01       Impact factor: 5.258

5.  A finite element model of heat transport in the human eye.

Authors:  J A Scott
Journal:  Phys Med Biol       Date:  1988-02       Impact factor: 3.609

6.  Anterior lens curvature. Comparisons between normal eyes and those with primary angle-closure glaucoma.

Authors:  R F Lowe
Journal:  Br J Ophthalmol       Date:  1972-05       Impact factor: 4.638

7.  Mechanics of pupil block.

Authors:  R Mapstone
Journal:  Br J Ophthalmol       Date:  1968-01       Impact factor: 4.638

8.  Anterior chamber dimensions in patients with narrow angles and angle-closure glaucoma.

Authors:  D A Lee; R F Brubaker; D M Ilstrup
Journal:  Arch Ophthalmol       Date:  1984-01

9.  Angle-closure, pupil dilatation, and pupil block.

Authors:  R F Lowe
Journal:  Br J Ophthalmol       Date:  1966-07       Impact factor: 4.638

10.  Ultrasound biomicroscopic and conventional ultrasonographic study of ocular dimensions in primary angle-closure glaucoma.

Authors:  G Marchini; A Pagliarusco; A Toscano; R Tosi; C Brunelli; L Bonomi
Journal:  Ophthalmology       Date:  1998-11       Impact factor: 12.079

View more
  4 in total

1.  Ocular Biometric Determinants of Anterior Chamber Angle Width in Chinese Americans: The Chinese American Eye Study.

Authors:  Benjamin Y Xu; Jacob Lifton; Bruce Burkemper; Xuejuan Jiang; Anmol A Pardeshi; Sasan Moghimi; Grace M Richter; Roberta McKean-Cowdin; Rohit Varma
Journal:  Am J Ophthalmol       Date:  2020-07-28       Impact factor: 5.258

2.  In vivo estimation of murine iris stiffness using finite element modeling.

Authors:  Chanyoung Lee; Guorong Li; W Daniel Stamer; C Ross Ethier
Journal:  Exp Eye Res       Date:  2020-11-28       Impact factor: 3.467

3.  An imaged-based inverse finite element method to determine in-vivo mechanical properties of the human trabecular meshwork.

Authors:  Anup D Pant; Larry Kagemann; Joel S Schuman; Ian A Sigal; Rouzbeh Amini
Journal:  J Model Ophthalmol       Date:  2017

4.  Peripheral laser iridoplasty opens angle in plateau iris by thinning the cross-sectional tissues.

Authors:  Ji Liu; Tania Lamba; David A Belyea
Journal:  Clin Ophthalmol       Date:  2013-09-23
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.