Literature DB >> 17698531

Increasing contrast agent concentration improves enhancement in first-pass CT perfusion.

H M Silvennoinen1, L M Hamberg, L Valanne, G J Hunter.   

Abstract

BACKGROUND AND
PURPOSE: Our aim was to evaluate whether increasing iodine concentration, at a constant total iodine dose, resulted in better brain tissue opacification in patients with acute stroke symptoms during their evaluation by first-pass CT perfusion (CTP).
MATERIALS AND METHODS: One hundred two patients presenting to the emergency department within 3 hours of onset of acute stroke symptoms underwent CTP scanning. Three different concentrations of iodinated nonionic contrast material were used (300, 350, or 400 mg/mL). Total iodine dose (15 g) and injection rate (7 mL/s) were kept constant. There were 25, 53, and 19 patients in the different concentration groups, respectively; 5 patients were excluded due to uncorrectable motion artifacts. CTP scanning was performed at the level of the putamen, and data were analyzed by determining peak opacification for normal gray and white matter, arterial input, and venous output. Mean and SD values were calculated, and 3 concentration groups, stratified by region-of-interest location, were compared by using a single-tailed unpaired t test.
RESULTS: Monotonic increasing peak opacification was observed in all region-of-interest locations. Statistically significant differences were observed between the 300 and 350 mg/mL, 300 and 400 mg/mL, as well as the 350 and 400 mg/mL groups (P<.01) in white matter, gray matter, and the arterial input. Statistical significance was seen in the venous output group between the 300 and 400 mg/mL (P<.005) and 350 and 400 mg/mL (P<.007) groups, but not between the 300 and 350 mg/mL (P=.2) groups.
CONCLUSION: Increasing contrast concentration improves peak opacification of tissue, suggesting that CTP evaluation of patients with acute stroke is better performed with the highest available concentration contrast agent.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17698531      PMCID: PMC7977633          DOI: 10.3174/ajnr.A0574

Source DB:  PubMed          Journal:  AJNR Am J Neuroradiol        ISSN: 0195-6108            Impact factor:   3.825


  16 in total

1.  Perfusion CT with iodinated contrast material.

Authors:  James D Eastwood; Michael H Lev; James M Provenzale
Journal:  AJR Am J Roentgenol       Date:  2003-01       Impact factor: 3.959

2.  User-defined vascular input function curves: influence on mean perfusion parameter values and signal-to-noise ratio.

Authors:  Susan M Kealey; Vilert A Loving; David M Delong; James D Eastwood
Journal:  Radiology       Date:  2004-04-02       Impact factor: 11.105

3.  MDCT angiography of the pulmonary arteries: influence of iodine flow concentration on vessel attenuation and visualization.

Authors:  Helmut Schoellnast; Hannes A Deutschmann; Gerald A Fritz; Uwe Stessel; Gottfried J Schaffler; Manfred Tillich
Journal:  AJR Am J Roentgenol       Date:  2005-06       Impact factor: 3.959

4.  Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to-noise.

Authors:  T Benner; S Heiland; G Erb; M Forsting; K Sartor
Journal:  Magn Reson Imaging       Date:  1997       Impact factor: 2.546

Review 5.  CT perfusion in acute stroke.

Authors:  Sanjay K Shetty; Michael H Lev
Journal:  Neuroimaging Clin N Am       Date:  2005-08       Impact factor: 2.264

6.  Quantitative high-resolution measurement of cerebrovascular physiology with slip-ring CT.

Authors:  L M Hamberg; G J Hunter; E F Halpern; B Hoop; G S Gazelle; G L Wolf
Journal:  AJNR Am J Neuroradiol       Date:  1996-04       Impact factor: 3.825

7.  Dynamic CT perfusion imaging of acute stroke.

Authors:  T E Mayer; G F Hamann; J Baranczyk; B Rosengarten; E Klotz; M Wiesmann; U Missler; G Schulte-Altedorneburg; H J Brueckmann
Journal:  AJNR Am J Neuroradiol       Date:  2000-09       Impact factor: 3.825

8.  The effect of varying user-selected input parameters on quantitative values in CT perfusion maps.

Authors:  Pina C Sanelli; Michael H Lev; James D Eastwood; R Gilberto Gonzalez; Ting Y Lee
Journal:  Acad Radiol       Date:  2004-10       Impact factor: 3.173

9.  Moderate versus high concentration of contrast material for aortic and hepatic enhancement and tumor-to-liver contrast at multi-detector row CT.

Authors:  Kazuo Awai; Masaaki Inoue; Yukinobu Yagyu; Manabu Watanabe; Toshiko Sano; Seiun Nin; Ryuta Koike; Yasumasa Nishimura; Yasuyuki Yamashita
Journal:  Radiology       Date:  2004-10-14       Impact factor: 11.105

10.  Perfusion CT and angio CT in the assessment of acute stroke.

Authors:  J M Esteban; V Cervera
Journal:  Neuroradiology       Date:  2004-09       Impact factor: 2.804

View more
  7 in total

Review 1.  Contrast medium administration and image acquisition parameters in renal CT angiography: what radiologists need to know.

Authors:  Charbel Saade; Ibrahim Alsheikh Deeb; Maha Mohamad; Hussain Al-Mohiy; Fadi El-Merhi
Journal:  Diagn Interv Radiol       Date:  2016 Mar-Apr       Impact factor: 2.630

2.  C-arm CT measurement of cerebral blood volume and cerebral blood flow using a novel high-speed acquisition and a single intravenous contrast injection.

Authors:  K Royalty; M Manhart; K Pulfer; Y Deuerling-Zheng; C Strother; A Fieselmann; D Consigny
Journal:  AJNR Am J Neuroradiol       Date:  2013-05-23       Impact factor: 3.825

3.  Effects of different tube potentials and iodine concentrations on image enhancement, contrast-to-noise ratio and noise in micro-CT images: a phantom study.

Authors:  Hairil Rashmizal Abdul Razak; Said Mohd Shaffiq Said Rahmat; Wan Mazlina Md Saad
Journal:  Quant Imaging Med Surg       Date:  2013-10

4.  Biased visualization of hypoperfused tissue by computed tomography due to short imaging duration: improved classification by image down-sampling and vascular models.

Authors:  Irene Klærke Mikkelsen; P Simon Jones; Lars Riisgaard Ribe; Josef Alawneh; Josep Puig; Susanne Lise Bekke; Anna Tietze; Jonathan H Gillard; Elisabeth A Warburton; Salva Pedraza; Jean-Claude Baron; Leif Østergaard; Kim Mouridsen
Journal:  Eur Radiol       Date:  2015-04-17       Impact factor: 5.315

5.  Contrast enhancement efficacy of iodinated contrast media: Effect of molecular structure on contrast enhancement.

Authors:  Kuniharu Imai; Mitsuru Ikeda; Yoshiki Satoh; Keisuke Fujii; Chiyo Kawaura; Takuya Nishimoto; Masaki Mori
Journal:  Eur J Radiol Open       Date:  2018-10-06

6.  Establishment of the intracranial hemodynamic model based on contrast medium and clinical applications.

Authors:  Yaoer Cheng; Wen He
Journal:  Medicine (Baltimore)       Date:  2016-12       Impact factor: 1.817

7.  The neuroimaging magnitude of pediatric brain atrophy in northern Tanzania.

Authors:  Richard Erasto Sungura; John Martin Spitsbergen; Emmanuel Abraham Mpolya; Elingarami Sauli; John-Mary Vianney
Journal:  Pan Afr Med J       Date:  2020-05-21
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.