Literature DB >> 9201678

Accuracy of gamma-variate fits to concentration-time curves from dynamic susceptibility-contrast enhanced MRI: influence of time resolution, maximal signal drop and signal-to-noise.

T Benner1, S Heiland, G Erb, M Forsting, K Sartor.   

Abstract

Concentration-time curves derived from dynamic susceptibility-contrast enhanced magnetic resonance imaging are widely used to calculate cerebrovascular parameters. To exclude effects of recirculation, a non-linear regression method is used to fit a gamma-variate function to the concentration-time course. In previous studies the errors arising from the fitting procedure have not been quantified. In a computer simulation we investigate the uncertainties of parameters calculated from the fitted gamma-variate function, exploring the dependencies on signal-to-noise (SNR), time resolution (delta t), and maximal signal drop (MSD). Our study was performed to give a framework on how to design MR-sequences and choose contrast media and their application in order to yield concentration-time curves which allow a reliable performance of the gamma-variate fitting procedure. We recorded 396 concentration-time curves from regions of interest of 40 patients. The gamma-variate fitting procedure was applied to these curves resulting in 396 parameter sets. Ideal concentration-time curves as gamma-variate functions were generated from these sets with a given delta t, MSD, and SNR. Recirculation effect was simulated. Then the gamma-variate fitting was performed again. From ideal and simulated gamma-variate function the area and the normalized first moment were calculated. The uncertainties of the values calculated from the simulated curve relating to the values of the original one were determined. Increase of SNR decreases the involved errors. With SNR values of 100 and more there is only minor influence of delta t and MSD and the fitted curve approximates the original data very well. Smaller values of SNR lead to a stronger influence of delta t and MSD and a higher number of fitting failures. With increasing delta t the uncertainties also increase. Intermediate values of MSD (30% to 70%) yield the smallest errors while increasing or decreasing MSD yields an increase of uncertainty. To achieve low uncertainties in the calculation of cerebrovascular parameters from gamma-variate fits, delta t of the imaging sequence and MSD must be considered. This is more important the lower SNR is. The shown dependencies should be taken into account when choosing MR sequence parameters and application of contrast media.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9201678     DOI: 10.1016/s0730-725x(96)00392-x

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  33 in total

1.  Correction for arterial-tissue delay and dispersion in absolute quantitative cerebral perfusion DSC MR imaging.

Authors:  Jessy J Mouannes-Srour; Wanyong Shin; Sameer A Ansari; Michael C Hurley; Parmede Vakil; Bernard R Bendok; John L Lee; Colin P Derdeyn; Timothy J Carroll
Journal:  Magn Reson Med       Date:  2011-12-12       Impact factor: 4.668

2.  Short-term changes in cerebral microhemodynamics after carotid stenting.

Authors:  Iain D Wilkinson; Paul D Griffiths; Nigel Hoggard; Trevor J Cleveland; Peter A Gaines; Sumaira Macdonald; Fiona McKevitt; Graham S Venables
Journal:  AJNR Am J Neuroradiol       Date:  2003-09       Impact factor: 3.825

3.  Robust quantification of microvascular transit times via linear dynamical systems using two-photon fluorescence microscopy data.

Authors:  Lakshminarayan V Chinta; Liis Lindvere; Bojana Stefanovic
Journal:  J Cereb Blood Flow Metab       Date:  2012-06-20       Impact factor: 6.200

4.  The impact of schizophrenia on frontal perfusion parameters: a DSC-MRI study.

Authors:  Denis Peruzzo; Gianluca Rambaldelli; Alessandra Bertoldo; Marcella Bellani; Roberto Cerini; Marini Silvia; Roberto Pozzi Mucelli; Michele Tansella; Paolo Brambilla
Journal:  J Neural Transm (Vienna)       Date:  2011-01-04       Impact factor: 3.575

5.  Diagnosis of suspicious breast lesions using an empirical mathematical model for dynamic contrast-enhanced MRI.

Authors:  Xiaobing Fan; Milica Medved; Gregory S Karczmar; Cheng Yang; Sean Foxley; Sanaz Arkani; Wendy Recant; Marta A Zamora; Hiroyuki Abe; Gillian M Newstead
Journal:  Magn Reson Imaging       Date:  2006-11-30       Impact factor: 2.546

6.  Increasing contrast agent concentration improves enhancement in first-pass CT perfusion.

Authors:  H M Silvennoinen; L M Hamberg; L Valanne; G J Hunter
Journal:  AJNR Am J Neuroradiol       Date:  2007-08       Impact factor: 3.825

7.  Analysis of the influence of 4D MR angiography temporal resolution on time-to-peak estimation error for different cerebral vessel structures.

Authors:  N D Forkert; T Illies; D Möller; H Handels; D Säring; J Fiehler
Journal:  AJNR Am J Neuroradiol       Date:  2012-05-03       Impact factor: 3.825

8.  Low-dose CT perfusion with projection view sharing.

Authors:  Thomas Martin; John Hoffman; Jeff R Alger; Michael McNitt-Gray; Danny Jj Wang
Journal:  Med Phys       Date:  2017-11-17       Impact factor: 4.071

9.  Comparison of dynamic susceptibility-weighted contrast-enhanced MR methods: recommendations for measuring relative cerebral blood volume in brain tumors.

Authors:  Eric S Paulson; Kathleen M Schmainda
Journal:  Radiology       Date:  2008-09-09       Impact factor: 11.105

Review 10.  Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities.

Authors:  Linda Knutsson; Freddy Ståhlberg; Ronnie Wirestam
Journal:  MAGMA       Date:  2009-12-04       Impact factor: 2.310

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.