Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device.

Eiki Akagawa1, Hwansung Lee, Eisuke Tatsumi, Akihiko Homma, Tomonori Tsukiya, Nobumasa Katagiri, Yukihide Kakuta, Tomohiro Nishinaka, Toshihide Mizuno, Kei Ota, Rei Kansaku, Yoshiyuki Taenaka.   

Abstract

We have been developing a pneumatic ventricular assist device (PVAD) system consisting of a diaphragm-type blood pump. The objective of the present study was to evaluate the flow pattern inside the PVAD, which may greatly affect thrombus formation, with respect to the inflow valve-mount orientation. To analyze the change of flow behavior caused by the orifice direction (OD) of the valve, the flow pattern in this pump was visualized. Particle image velocimetry was used as a measurement technique to visualize the flow dynamics. A monoleaflet mechanical valve was mounted in the inlet and outlet ports of the PVAD, which was connected to a mock circulatory loop tester. The OD of the inlet valve was set at six different angles (OD = 0 degrees, 45 degrees, 90 degrees, 135 degrees, 180 degrees, and 270 degrees, where the OD opening toward the diaphragm was defined as 0 degrees ) and the pump rate was fixed at 80 bpm to create a 5.0 l/min flow rate. The main circular flow in the blood pump was affected by the OD of the inlet valve. The observed regional flow velocity was relatively low in the area between the inlet and outlet port roots, and was lowest at an OD of 90 degrees. In contrast, the regional flow velocity in this area was highest at an OD of 135 degrees. The OD is an important factor in optimizing the flow condition in our PVAD in terms of preventing flow stagnation, and the best flow behavior was realized at an OD of 135 degrees.

Entities:  

Mesh:

Year:  2007        PMID: 17574510     DOI: 10.1007/s10047-007-0378-z

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  12 in total

1.  The closing behavior of mechanical aortic heart valve prostheses.

Authors:  Po-Chien Lu; Jia-Shing Liu; Ren-Hong Huang; Chi-Wen Lo; Ho-Cheng Lai; Ned H C Hwang
Journal:  ASAIO J       Date:  2004 Jul-Aug       Impact factor: 2.872

2.  Correlation of in vivo clot deposition with the flow characteristics in the 50 cc penn state artificial heart: a preliminary study.

Authors:  Pramote Hochareon; Keefe B Manning; Arnold A Fontaine; John M Tarbell; Steven Deutsch
Journal:  ASAIO J       Date:  2004 Nov-Dec       Impact factor: 2.872

3.  Off-design considerations of the 50cc Penn State Ventricular Assist Device.

Authors:  Leslie A Oley; Keefe B Manning; Arnold A Fontaine; Steven Deutsch
Journal:  Artif Organs       Date:  2005-05       Impact factor: 3.094

Review 4.  The status of failure and reliability testing of artificial blood pumps.

Authors:  Sonna M Patel; Amy L Throckmorton; Alexandrina Untaroiu; Paul E Allaire; Houston G Wood; Don B Olsen
Journal:  ASAIO J       Date:  2005 Jul-Aug       Impact factor: 2.872

5.  Design of a hydraulic analog of the circulatory system for evaluating artificial hearts.

Authors:  F M Donovan
Journal:  Biomater Med Devices Artif Organs       Date:  1975

6.  The 50cc Penn State left ventricular assist device: a parametric study of valve orientation flow dynamics.

Authors:  James W Kreider; Keefe B Manning; Leslie A Oley; Arnold A Fontaine; Steven Deutsch
Journal:  ASAIO J       Date:  2006 Mar-Apr       Impact factor: 2.872

7.  Study of the effect of atrial contraction on mitral prosthetic valve by high speed video camera.

Authors:  K Naemura; M Sonderegger; H Matsumoto; T Dohi; K Izumi; T Fujimoto; M Umezu; Y Ota
Journal:  Artif Organs       Date:  1997-04       Impact factor: 3.094

8.  Fluid dynamic optimization of a ventricular assist device using particle image velocimetry.

Authors:  T Mussivand; K D Day; B C Naber
Journal:  ASAIO J       Date:  1999 Jan-Feb       Impact factor: 2.872

Review 9.  Thromboembolic complication of prosthetic devices.

Authors:  S Berger; E W Salzman
Journal:  Prog Hemost Thromb       Date:  1974

10.  Multi-institutional studies of the National Cardiovascular Center Ventricular Assist System: use in 92 patients.

Authors:  H Takano; Y Taenaka; H Noda; M Kinoshita; A Yagura; E Tatsumi; H Sekii; E Sasaki; M Umezu; T Nakatani
Journal:  ASAIO Trans       Date:  1989 Jul-Sep
View more
  7 in total

1.  Flow visualization for different port angles of a pulsatile ventricular assist device.

Authors:  Eiki Akagawa; Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2011-10-30       Impact factor: 1.731

2.  Hemodynamic influence of tilting disc valve type on pump performance with the NIPRO-ventricular assist device.

Authors:  Mitsutoshi Kimura; Takashi Nishimura; Osamu Kinoshita; Koichi Kashiwa; Shunei Kyo; Minoru Ono
Journal:  J Artif Organs       Date:  2011-11-11       Impact factor: 1.731

3.  Characteristics of cavitation intensity in a mechanical heart valve using a pulsatile device: synchronized analysis between visual images and pressure signals.

Authors:  Hwansung Lee; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2008-07-06       Impact factor: 1.731

4.  Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.

Authors:  Hwansung Lee; Yoshiaki Ikeuchi; Eiki Akagawa; Eisuke Tatsumi; Yoshiyuki Taenaka; Takao Yamamoto
Journal:  J Artif Organs       Date:  2009-06-18       Impact factor: 1.731

Review 5.  Journal of Artificial Organs 2007: the year in review.

Authors:  Y Sawa; E Tatsumi; A Funakubo; T Horiuchi; K Iwasaki; A Kishida; T Masuzawa; K Matsuda; M Nishimura; T Nishimura; Y Tomizawa; T Yamaoka; H Watanabe
Journal:  J Artif Organs       Date:  2008-04-15       Impact factor: 1.731

6.  Duration of Systole and Diastole for Hydrodynamic Testing of Prosthetic Heart Valves: Comparison Between ISO 5840 Standards and in vivo Studies.

Authors:  Ovandir Bazan; Jayme Pinto Ortiz
Journal:  Braz J Cardiovasc Surg       Date:  2016-04

7.  Development of a compact wearable pneumatic drive unit for a ventricular assist device.

Authors:  Akihiko Homma; Yoshiyuki Taenaka; Eisuke Tatsumi; Eiki Akagawa; Hwansung Lee; Tomohiro Nishinaka; Yoshiaki Takewa; Toshihide Mizuno; Tomonori Tsukiya; Yukihide Kakuta; Nobumasa Katagiri; Isao Shimosaki; Shigeru Hamada; Hiroshi Mukaibayashi; Wataru Iwaoka
Journal:  J Artif Organs       Date:  2008-12-17       Impact factor: 1.731

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.