Literature DB >> 22076421

Hemodynamic influence of tilting disc valve type on pump performance with the NIPRO-ventricular assist device.

Mitsutoshi Kimura1, Takashi Nishimura, Osamu Kinoshita, Koichi Kashiwa, Shunei Kyo, Minoru Ono.   

Abstract

The NIPRO-ventricular assist device (NIPRO-VAD) is an external pulsatile flow pump. Formerly, Sorin Carbocast, a monoleaflet tilting disc valve (SC valve), was used at the inlet/outlet parts of the pump, but Medtronic Hall (MH valve) is now used. We studied the differences in performance among pumps with different artificial valves. Six NIPRO pumps with SC valves and six with MH valves were examined using mock circuits. The systolic flow of the pump was measured with the ultrasonic flowmeter by changing the systolic fraction. Six patients wearing the NIPRO-VAD underwent periodic pump exchange from a pump with an SC valve to the one with an MH valve. The pump blood flow was measured at pre- and post-pump exchanges using an ultrasonic flowmeter. Blood pressure, serum LDH and AST levels were also compared before and after the pump exchange. Blood flow was significantly increased by using the NIPRO-VAD with the MH valve as compared to the SC valve in vitro. Under the same drive conditions pump flow tended to increase in six patients. No difference was found in patients' blood pressure, serum LDH or AST levels when using the SC or MH valve. From these results, the hemodynamic influence on patients due to replacement of the SC valve with the MH valve in the NIPRO-VAD is considered to be insignificant.

Entities:  

Mesh:

Year:  2011        PMID: 22076421     DOI: 10.1007/s10047-011-0616-2

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  10 in total

1.  Flow visualization of a monoleaflet and bileaflet mechanical heart valve in a pneumatic ventricular assist device using a PIV system.

Authors:  Hwansung Lee; Eisuke Tatsumi; Yoshiyuki Taenaka
Journal:  ASAIO J       Date:  2010 May-Jun       Impact factor: 2.872

2.  Emergency reinforcement of cracked paracorporeal blood pumps.

Authors:  Heinrich Schima; Christian Reindl; Martin Stoiber; Wilfried Röthy; Georg Wieselthaler
Journal:  ASAIO J       Date:  2004 Nov-Dec       Impact factor: 2.872

3.  Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device.

Authors:  Eiki Akagawa; Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Nobumasa Katagiri; Yukihide Kakuta; Tomohiro Nishinaka; Toshihide Mizuno; Kei Ota; Rei Kansaku; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

4.  Patterns of normal transvalvular regurgitation in mechanical valve prostheses.

Authors:  F A Flachskampf; J P O'Shea; B P Griffin; L Guerrero; A E Weyman; J D Thomas
Journal:  J Am Coll Cardiol       Date:  1991-11-15       Impact factor: 24.094

5.  Characterization and optimization of the flow pattern inside a diaphragm blood pump based on flow visualization techniques.

Authors:  M Nakata; T Masuzawa; E Tatsumi; Y Taenaka; T Nishimura; T Tsukiya; H Takano; K Tsuchimoto; K Ohba
Journal:  ASAIO J       Date:  1998 Sep-Oct       Impact factor: 2.872

6.  High-dose carvedilol therapy for mechanical circulatory assisted patients.

Authors:  Takashi Nishimura; Shunei Kyo
Journal:  J Artif Organs       Date:  2010-04-03       Impact factor: 1.731

7.  Circulatory maintenance with a single artificial heart.

Authors:  H Takano; Y Taenaka; T Nakatani; M Umezu; T Matsuda; H Iwata; T Tanaka; H Noda; K Hayashi; S Takatani
Journal:  Trans Am Soc Artif Intern Organs       Date:  1984

8.  Improved long-term performance of pulsatile extracorporeal left ventricular assist device.

Authors:  Taro Sasaoka; Tomoko S Kato; Kazuo Komamura; Ayako Takahashi; Ikutaro Nakajima; Noboru Oda; Akihisa Hanatani; Akiko Mano; Masanori Asakura; Kazuhiko Hashimura; Kazuo Niwaya; Toshihiro Funatsu; Junjiro Kobayashi; Soichiro Kitamura; Toshiaki Shishido; Kyoichi Wada; Shigeki Miyata; Takeshi Nakatani; Mitsuaki Isobe; Masafumi Kitakaze
Journal:  J Cardiol       Date:  2010-07-07       Impact factor: 3.159

9.  Age and preoperative total bilirubin level can stratify prognosis after extracorporeal pulsatile left ventricular assist device implantation.

Authors:  Taro Shiga; Koichiro Kinugawa; Masaru Hatano; Atsushi Yao; Takashi Nishimura; Miyoko Endo; Naoko Kato; Yasunobu Hirata; Shunei Kyo; Minoru Ono; Ryozo Nagai
Journal:  Circ J       Date:  2010-11-23       Impact factor: 2.993

10.  Fifteen-year experience with Toyobo paracorporeal left ventricular assist system.

Authors:  Shunsuke Saito; Goro Matsumiya; Taichi Sakaguchi; Tomoyuki Fujita; Toru Kuratani; Hajime Ichikawa; Yoshiki Sawa
Journal:  J Artif Organs       Date:  2009-03-29       Impact factor: 1.731

  10 in total
  4 in total

Review 1.  Current status of extracorporeal ventricular assist devices in Japan.

Authors:  Takashi Nishimura
Journal:  J Artif Organs       Date:  2014-06-22       Impact factor: 1.731

Review 2.  Journal of Artificial Organs 2012: the year in review.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2013-02-28       Impact factor: 1.731

Review 3.  Technology landscape of pediatric mechanical circulatory support devices: A systematic review 2010-2021.

Authors:  Thomas Palazzolo; Matthew Hirschhorn; Ellen Garven; Steven Day; Randy M Stevens; Joseph Rossano; Vakhtang Tchantchaleishvili; Amy L Throckmorton
Journal:  Artif Organs       Date:  2022-04-14       Impact factor: 2.663

4.  Severe hemolytic anemia caused by the NIPRO extracorporeal left ventricular assist device.

Authors:  Ikuko Shibasaki; Toshiyuki Kuwata; Go Tsuchiya; Hironaga Ogawa; Yasuyuki Yamada; Shigeru Toyoda; Teruo Inoue; Hirotsugu Fukuda
Journal:  Gen Thorac Cardiovasc Surg       Date:  2016-01-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.