Literature DB >> 22038496

Flow visualization for different port angles of a pulsatile ventricular assist device.

Eiki Akagawa1, Hwansung Lee, Eisuke Tatsumi, Akihiko Homma, Tomonori Tsukiya, Yoshiyuki Taenaka.   

Abstract

The "washout effect" inside a blood pump may depend in part on the configuration of the blood pump, including its "port angle." The port angle, which is primarily decided based on anatomical considerations, may also be important from the rheological viewpoint. In our department, a next-generation diaphragm-type blood pump is being developed. In this study, we examined the influence of the port angle on flow conditions inside our new blood pump. Acrylic resin mock pumps with three different port angles (0°, 30°, and 45°) were prepared for flow visualization. Mechanical monoleaflet valves were mounted on the inlet and outlet ports of the mock pumps. Flow conditions within the mock pumps were visualized by means of particle image velocimetry during a half stroke. As a result, a high flow velocity region was seen along the main circular flow from the inlet to the outlet port. This circular flow was almost uniform and parallel to the plane of the diaphragm-housing junction (DhJ) when viewed from the inlet and outlet sides. Moreover, the proportion of high flow velocity vectors in the plane in the vicinity of the DhJ decreased as the degree of the port angle increased. In conclusion, we found that the flow behavior in the plane in the vicinity of the DhJ changed with the port angle, and that a port angle of 0° may be suitable for our diaphragm-type blood pump in view of the washout effect.

Entities:  

Mesh:

Year:  2011        PMID: 22038496     DOI: 10.1007/s10047-011-0614-4

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  13 in total

1.  Visualization study of the transient flow in the centrifugal blood pump impeller.

Authors:  Tomonori Tsukiya; Yoshiyuki Taenaka; Eisuke Tatsumi; Hisateru Takano
Journal:  ASAIO J       Date:  2002 Jul-Aug       Impact factor: 2.872

2.  Correlation of in vivo clot deposition with the flow characteristics in the 50 cc penn state artificial heart: a preliminary study.

Authors:  Pramote Hochareon; Keefe B Manning; Arnold A Fontaine; John M Tarbell; Steven Deutsch
Journal:  ASAIO J       Date:  2004 Nov-Dec       Impact factor: 2.872

3.  Off-design considerations of the 50cc Penn State Ventricular Assist Device.

Authors:  Leslie A Oley; Keefe B Manning; Arnold A Fontaine; Steven Deutsch
Journal:  Artif Organs       Date:  2005-05       Impact factor: 3.094

4.  Quantification of the secondary flow in a radial coupled centrifugal blood pump based on particle tracking velocimetry.

Authors:  Nobuo Watanabe; Takaya Masuda; Tomoya Iida; Hiroyuki Kataoka; Tetsuo Fujimoto; Setsuo Takatani
Journal:  Artif Organs       Date:  2005-01       Impact factor: 3.094

5.  Design of a hydraulic analog of the circulatory system for evaluating artificial hearts.

Authors:  F M Donovan
Journal:  Biomater Med Devices Artif Organs       Date:  1975

6.  Effects of mechanical valve orifice direction on the flow pattern in a ventricular assist device.

Authors:  Eiki Akagawa; Hwansung Lee; Eisuke Tatsumi; Akihiko Homma; Tomonori Tsukiya; Nobumasa Katagiri; Yukihide Kakuta; Tomohiro Nishinaka; Toshihide Mizuno; Kei Ota; Rei Kansaku; Yoshiyuki Taenaka
Journal:  J Artif Organs       Date:  2007-06-20       Impact factor: 1.731

7.  The 50cc Penn State left ventricular assist device: a parametric study of valve orientation flow dynamics.

Authors:  James W Kreider; Keefe B Manning; Leslie A Oley; Arnold A Fontaine; Steven Deutsch
Journal:  ASAIO J       Date:  2006 Mar-Apr       Impact factor: 2.872

8.  Fluid dynamic optimization of a ventricular assist device using particle image velocimetry.

Authors:  T Mussivand; K D Day; B C Naber
Journal:  ASAIO J       Date:  1999 Jan-Feb       Impact factor: 2.872

9.  Flow visualization study on centrifugal blood pump using a high speed video camera.

Authors:  I Sakuma; H Tadokoro; Y Fukui; T Dohi
Journal:  Artif Organs       Date:  1995-07       Impact factor: 3.094

10.  Flow pattern analysis of the Baylor total artificial heart.

Authors:  D Meier; J T Wernicke; Y Orime; S Takatani; K Tasai; G Damm; K Naito; K Mizuguchi; K Makinouchi; J Glueck
Journal:  Artif Organs       Date:  1994-12       Impact factor: 3.094

View more
  4 in total

Review 1.  Journal of Artificial Organs 2012: the year in review.

Authors:  Y Sawa; E Tatsumi; T Tsukiya; K Matsuda; K Fukunaga; A Kishida; T Masuzawa; G Matsumiya; A Myoui; M Nishimura; T Nishimura; T Nishinaka; E Okamoto; S Tokunaga; T Tomo; Y Yagi; T Yamaoka
Journal:  J Artif Organs       Date:  2013-02-28       Impact factor: 1.731

2.  Microfluidic Deformability Study of an Innovative Blood Analogue Fluid Based on Giant Unilamellar Vesicles.

Authors:  Denise A M Carvalho; Ana Rita O Rodrigues; Vera Faustino; Diana Pinho; Elisabete M S Castanheira; Rui Lima
Journal:  J Funct Biomater       Date:  2018-12-04

Review 3.  Blood Particulate Analogue Fluids: A Review.

Authors:  Samir Hassan Sadek; Manuel Rubio; Rui Lima; Emilio José Vega
Journal:  Materials (Basel)       Date:  2021-05-09       Impact factor: 3.623

4.  Methods for determination of stagnation in pneumatic ventricular assist devices.

Authors:  Damian Obidowski; Piotr Reorowicz; Dariusz Witkowski; Krzysztof Sobczak; Krzysztof Jóźwik
Journal:  Int J Artif Organs       Date:  2018-08-03       Impact factor: 1.595

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.