Effects of leaflet geometry on the flow field in three bileaflet valves when installed in a pneumatic ventricular assist device.

Hwansung Lee1, Yoshiaki Ikeuchi, Eiki Akagawa, Eisuke Tatsumi, Yoshiyuki Taenaka, Takao Yamamoto.   

Abstract

Our group is currently developing a pneumatic ventricular assist device (PVAD). In this study, in order to select the optimal bileaflet valve for our PVAD, three kinds of bileaflet valve were installed and the flow was visualized downstream of the outlet valve using the particle image velocimetry (PIV) method. To carry out flow visualization inside the blood pump and near the valve, we designed a model pump that had the same configuration as our PVAD. The three bileaflet valves tested were a 21-mm ATS valve, a 21-mm St. Jude valve, and a 21-mm Sorin Bicarbon valve. The mechanical heart valves were mounted at the aortic position of the model pump and the flow was visualized by using the PIV method. The maximum flow velocity was measured at three distances (0, 10, and 30 mm) from the valve plane. The maximum flow velocity of the Sorin Bicarbon valve was less than that of the other two valves; however, it decreased slightly with increasing distance it the X-Y plane in all three valves. Although different bileaflet valves are very similar in design, the geometry of the leaflet is an important factor when selecting a mechanical heart valve for use in an artificial heart.

Entities:  

Mesh:

Year:  2009        PMID: 19536626     DOI: 10.1007/s10047-009-0453-8

Source DB:  PubMed          Journal:  J Artif Organs        ISSN: 1434-7229            Impact factor:   1.731


  22 in total

1.  Particle image velocimetry investigation of intravalvular flow fields of a bileaflet mechanical heart valve in a pulsatile flow.

Authors:  A Subramanian; H Mu; J R Kadambi; M P Wernet; A M Brendzel; H Harasaki
Journal:  J Heart Valve Dis       Date:  2000-09

2.  Pulsatile flow studies of a porcine bioprosthetic aortic valve in vitro: PIV measurements and shear-induced blood damage.

Authors:  W L Lim; Y T Chew; T C Chew; H T Low
Journal:  J Biomech       Date:  2001-11       Impact factor: 2.712

3.  Numerical estimation of blood damage in artificial organs.

Authors:  Leonid Goubergrits; Klaus Affeld
Journal:  Artif Organs       Date:  2004-05       Impact factor: 3.094

Review 4.  Mechanical cardiac support 2000: current applications and future trial design.

Authors:  L W Stevenson; R L Kormos
Journal:  J Heart Lung Transplant       Date:  2001-01       Impact factor: 10.247

5.  Acoustic and visual characteristics of cavitation induced by mechanical heart valves.

Authors:  Kwanghyun Sohn; Keefe B Manning; Arnold A Fontaine; John M Tarbell; Steven Deutsch
Journal:  J Heart Valve Dis       Date:  2005-07

6.  Design and in vitro performance of a novel bileaflet mechanical heart valve prosthesis.

Authors:  D Medart; C Schmitz; G Rau; H Reul
Journal:  Int J Artif Organs       Date:  2005-03       Impact factor: 1.595

7.  An experimental study of steady flow patterns of a new trileaflet mechanical aortic valve.

Authors:  Jia-Shing Liu; Po-Chien Lu; Chi-Wen Lo; Ho-Cheng Lai; Ned H C Hwang
Journal:  ASAIO J       Date:  2005 Jul-Aug       Impact factor: 2.872

8.  Effect of the diastolic and systolic duration on valve cavitation in a pediatric pulsatile ventricular assist device.

Authors:  Branka Lukic; Conrad M Zapanta; Kimberly A Griffith; William J Weiss
Journal:  ASAIO J       Date:  2005 Sep-Oct       Impact factor: 2.872

9.  Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart.

Authors:  Hwansung Lee; Yoshiyuki Taenaka; Soichiro Kitamura
Journal:  ASAIO J       Date:  2005 May-Jun       Impact factor: 2.872

10.  Red blood cell damage by shear stress.

Authors:  L B Leverett; J D Hellums; C P Alfrey; E C Lynch
Journal:  Biophys J       Date:  1972-03       Impact factor: 4.033

View more
  1 in total

Review 1.  Journal of Artificial Organs 2009: the year in review.

Authors: 
Journal:  J Artif Organs       Date:  2010-03-24       Impact factor: 1.731

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.