Literature DB >> 17401588

Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Annette Rabel1, Steffen Gerhard Köhler, Andrea Maria Schmidt-Westhausen.   

Abstract

Primary stability has a major impact on the long-term success of dental implants. The aim of this study was to investigate the correlation of resonance frequency analysis (RFA) and insertion torque of self-tapping and non-self-tapping implants and their respective differences in primary stability. A group of 263 patients were treated with a total of 602 conically formed dental implants: 408 non-self-tapping Ankylos and 194 self-tapping Camlog. The maximum insertion torque during implant placement was recorded. Resonance frequency, measured as the implant stability quotient (ISQ), was assessed once immediately after insertion and twice 3 months later. Torque values of the non-self-tapping implants were significantly higher than those in the self-tapping group (p = 0.023). RFA did not show differences between the 2 groups (p = 0.956), but a correlation between ISQ values after implantation and 3 months after implant placement was measured (r = 0.712). Within the implant systems, no correlation between insertion torque and resonance frequency values could be determined (r = 0.305). Our study indicates that the ISQ values obtained from different implant systems are not comparable. The RFA does not appear suitable for the evaluation of implant stability when used as a single method. Higher insertion torque of the non-self-tapping implants appeared to confirm higher clinical primary stability.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17401588     DOI: 10.1007/s00784-007-0115-2

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  40 in total

1.  A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study.

Authors:  B Friberg; L Sennerby; N Meredith; U Lekholm
Journal:  Int J Oral Maxillofac Surg       Date:  1999-08       Impact factor: 2.789

2.  Bone classification: clinical-histomorphometric comparison.

Authors:  P Trisi; W Rao
Journal:  Clin Oral Implants Res       Date:  1999-02       Impact factor: 5.977

3.  Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants.

Authors:  Dominic O'Sullivan; Lars Sennerby; Neil Meredith
Journal:  Clin Oral Implants Res       Date:  2004-08       Impact factor: 5.977

4.  Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study.

Authors:  Ikuya Miyamoto; Yoichi Tsuboi; Eishin Wada; Hirohiko Suwa; Tadahiko Iizuka
Journal:  Bone       Date:  2005-09-08       Impact factor: 4.398

5.  Resonance frequency analysis and damping capacity assessment. Part I: an in vitro study on measurement reliability and a method of comparison in the determination of primary dental implant stability.

Authors:  Stefan Lachmann; Berthold Jäger; Detlef Axmann; German Gomez-Roman; Martin Groten; Heiner Weber
Journal:  Clin Oral Implants Res       Date:  2006-02       Impact factor: 5.977

6.  Primary stability of a conical implant and a hybrid, cylindric screw-type implant in vitro.

Authors:  Jun Sakoh; Ulrich Wahlmann; Elmar Stender; Rer Nat; Bilal Al-Nawas; Wilfried Wagner
Journal:  Int J Oral Maxillofac Implants       Date:  2006 Jul-Aug       Impact factor: 2.804

7.  Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens.

Authors:  B Friberg; L Sennerby; J Roos; U Lekholm
Journal:  Clin Oral Implants Res       Date:  1995-12       Impact factor: 5.977

8.  Implant stability measurements for implants placed at the time of extraction: a cohort, prospective clinical trial.

Authors:  William Becker; Lars Sennerby; Edwin Bedrossian; Burton E Becker; Jean Pierre Lucchini
Journal:  J Periodontol       Date:  2005-03       Impact factor: 6.993

9.  Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement.

Authors:  I Turkyilmaz; T F Tözüm; C Tumer; E N Ozbek
Journal:  J Oral Rehabil       Date:  2006-12       Impact factor: 3.837

10.  [Resonance frequency analysis in immediate loading of dental implants].

Authors:  J Horwitz; O Zuabi; M Peled
Journal:  Refuat Hapeh Vehashinayim (1993)       Date:  2003-07
View more
  22 in total

1.  Relation between insertion torque and bone-implant contact percentage: an artificial bone study.

Authors:  Cheng Liu; Ming-Tzu Tsai; Heng-Li Huang; Michael Yuan-Chien Chen; Jui-Ting Hsu; Kuo-Chih Su; Chih-Han Chang; Aaron Yu-Jen Wu
Journal:  Clin Oral Investig       Date:  2012-01-10       Impact factor: 3.573

2.  Analysis of the influence of implant shape on primary stability using the correlation of multiple methods.

Authors:  Mariana Lima da Costa Valente; Denise Tornavoi de Castro; Antonio Carlos Shimano; César Penazzo Lepri; Andréa Cândido dos Reis
Journal:  Clin Oral Investig       Date:  2015-02-14       Impact factor: 3.573

3.  Early outcome of an implant system with a resorbable adhesive calcium-phosphate coating--a prospective clinical study in partially dentate patients.

Authors:  Victor Palarie; Constantin Bicer; Karl M Lehmann; Mohammad Zahalka; Florian G Draenert; Peer W Kämmerer
Journal:  Clin Oral Investig       Date:  2011-08-06       Impact factor: 3.573

4.  The effect of various thread designs on the initial stability of taper implants.

Authors:  Ju-Hee Park; Young-Jun Lim; Myung-Joo Kim; Ho-Beom Kwon
Journal:  J Adv Prosthodont       Date:  2009-03-31       Impact factor: 1.904

5.  A retrospective study on related factors affecting the survival rate of dental implants.

Authors:  Hee-Won Jang; Jeong-Kyung Kang; Ki Lee; Yong-Sang Lee; Pil-Kyoo Park
Journal:  J Adv Prosthodont       Date:  2011-12-28       Impact factor: 1.904

6.  The effect of the thread depth on the mechanical properties of the dental implant.

Authors:  Sun-Young Lee; Sung-Jun Kim; Hyun-Wook An; Hyun-Seung Kim; Dong-Guk Ha; Kyung-Ho Ryo; Kwang-Bum Park
Journal:  J Adv Prosthodont       Date:  2015-04-23       Impact factor: 1.904

7.  Correlation between the thickness of the crestal and buccolingual cortical bone at varying depths and implant stability quotients.

Authors:  Kanthanat Chatvaratthana; Sita Thaworanunta; Dutmanee Seriwatanachai; Natthamet Wongsirichat
Journal:  PLoS One       Date:  2017-12-27       Impact factor: 3.240

8.  Early loading of hydrophilic titanium implants inserted in low-mineralized (D3 and D4) bone: one year results of a prospective clinical trial.

Authors:  Uwe Held; Dennis Rohner; Daniel Rothamel
Journal:  Head Face Med       Date:  2013-12-09       Impact factor: 2.151

9.  Early marginal bone stability of dental implants placed in a transalveolarly augmented maxillary sinus: a controlled retrospective study of surface modification with calcium ions.

Authors:  Eduardo Anitua; Laura Piñas; Mohammad Hamdan Alkhraisat
Journal:  Int J Implant Dent       Date:  2017-12-04

10.  Comparison of sandblasted and acid-etched surface implants and new hydrophilic surface implants in the posterior maxilla using a 3-month early-loading protocol: a randomized controlled trial.

Authors:  Hyeong Gi Kim; Pil-Young Yun; Young-Kyun Kim; Il-Hyung Kim
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2021-06-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.