Literature DB >> 17168930

Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement.

I Turkyilmaz1, T F Tözüm, C Tumer, E N Ozbek.   

Abstract

The aim of this study was to determine the bone density in the designated implant sites using computerized tomography (CT), the fastening torque values of dental implants, and the implant stability values using resonance frequency analysis. Further aim was to evaluate a possible correlation between bone density, fastening torque and implant stability. Eighty-five patients were treated with 158 Brånemark System implants. CT machine was used for preoperative evaluation of the jawbone for each patient, and bone densities were recorded in Hounsfield units (HU). The fastening torque values of all implants were recorded with the OsseoCare equipment. Implant stability measurements were performed with the Osstell machine. The average bone density and fastening torque values were 751.4 +/- 256 HU and 39.7 +/- 7 Ncm for 158 implants. The average primary implant stability was 73.2 +/- 6 ISQ for seventy implants. Strong correlations were observed between the bone density, fastening torque and implant stability values of Brånemark System TiUnite MKIII implants at implant placement (P < 0.001). These results strengthen the hypothesis that it may be possible to predict and quantify initial implant stability and bone quality from pre-surgical CT diagnosis.

Entities:  

Mesh:

Year:  2006        PMID: 17168930     DOI: 10.1111/j.1365-2842.2006.01692.x

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  21 in total

1.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

Review 2.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

3.  Influence of cone beam CT scanning parameters on grey value measurements at an implant site.

Authors:  A Parsa; N Ibrahim; B Hassan; A Motroni; P van der Stelt; D Wismeijer
Journal:  Dentomaxillofac Radiol       Date:  2012-08-29       Impact factor: 2.419

4.  Highly Nonlinear Solitary Waves for the Assessment of Dental Implant Mobility.

Authors:  Bruk Berhanu; Piervincenzo Rizzo; Mark Ochs
Journal:  J Appl Mech       Date:  2012-11-20       Impact factor: 2.168

5.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

6.  Influence of cortical bone anchorage on the primary stability of dental implants.

Authors:  Anne Kelly de Oliveira Nicolau Mantovani; Ivete Aparecida de Mattias Sartori; Luciana Reis Azevedo-Alanis; Rodrigo Tiossi; Flávia Noemy Gasparini Kiatake Fontão
Journal:  Oral Maxillofac Surg       Date:  2018-06-06

7.  Variability of dental cone beam CT grey values for density estimations.

Authors:  R Pauwels; O Nackaerts; N Bellaiche; H Stamatakis; K Tsiklakis; A Walker; H Bosmans; R Bogaerts; R Jacobs; K Horner
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

Review 8.  Evaluation of functional dynamics during osseointegration and regeneration associated with oral implants.

Authors:  Po-Chun Chang; Niklaus P Lang; William V Giannobile
Journal:  Clin Oral Implants Res       Date:  2010-01       Impact factor: 5.977

9.  Is trabecular bone related to primary stability of miniscrews?

Authors:  Mariana Marquezan; Inayá Lima; Ricardo Tadeu Lopes; Eduardo Franzotti Sant'Anna; Margareth Maria Gomes de Souza
Journal:  Angle Orthod       Date:  2013-11-18       Impact factor: 2.079

Review 10.  Immediate loading implants: review of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.