Analysis of the influence of implant shape on primary stability using the correlation of multiple methods.

Mariana Lima da Costa Valente1, Denise Tornavoi de Castro1, Antonio Carlos Shimano2, César Penazzo Lepri3, Andréa Cândido dos Reis4.   

Abstract

OBJECTIVES: The purpose of this study was to analyze the influence of the shape of various implants and the density of substrate on primary stability using a combination of methods.
MATERIALS AND METHODS: Fifty-four Neodent® brand cylindrical and conical implants with different prosthetic platforms were used. Implants were inserted into a pork rib bone and polyurethane blocks. Primary stability was assessed by insertion torque (IT), resonance frequency analysis (RFA), and pullout strength. Screws were also analyzed by scanning electron microscopy (SEM) before insertion and after removal to justify their use for inserting in different substrates.
RESULTS: The conical cone morse implant had the highest average for all of the assays performed and was significantly different (p < 0.05) from the cylindrical implants for IT in the bone, pullout strength in the 40 per cubic foot (PCF) polyurethane, and the bone. The internal hex cylindrical implant had the lowest averages, which were significantly different (p < 0.05) from the conical implants for IT and RFA in the bone, pullout strength in the 40 PCF polyurethane, and the bone. The IT, RFA, and pullout strength assays were moderately correlated, and the photomicrographs did not reveal changes in the implants.
CONCLUSIONS: The analysis of different implants showed a better primary stability of tapered implants; the density of the substrate influences the primary stability and the 15 PCF polyurethane was not adequate to evaluate primary stability; correlation was obtained between the different methodologies of analysis of primary stability. CLINICAL RELEVANCE: The study shows the influence of different implant macro-geometries and densities of substrates on primary stability.

Entities:  

Keywords:  Bone substitutes; Dental implants; Osseointegration; Scanning electron microscopy; Torque

Mesh:

Substances:

Year:  2015        PMID: 25677241     DOI: 10.1007/s00784-015-1417-4

Source DB:  PubMed          Journal:  Clin Oral Investig        ISSN: 1432-6981            Impact factor:   3.573


  25 in total

1.  Biomechanical evaluation of the primary stability of pedicle screws after augmentation with an innovative bone stabilizing system.

Authors:  K Wegmann; S Gick; C Heidemann; D Pennig; W F Neiss; L P Müller; P Eysel; R Sobottke
Journal:  Arch Orthop Trauma Surg       Date:  2013-09-01       Impact factor: 3.067

2.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

3.  Primary stability, insertion torque, and bone density of conical implants with internal hexagon: is there a relationship?

Authors:  Paolo Trisi; Davide Berardi; Michele Paolantonio; Giuseppe Spoto; Antonio D'Addona; Giorgio Perfetti
Journal:  J Craniofac Surg       Date:  2013-05       Impact factor: 1.046

4.  The effect of implant design on insertion torque and immediate micromotion.

Authors:  Amilcar C Freitas; Estevam A Bonfante; Gabriela Giro; Malvin N Janal; Paulo G Coelho
Journal:  Clin Oral Implants Res       Date:  2011-03-23       Impact factor: 5.977

5.  Physical properties of nano-HAs/ZrO2 coating on surface of titanium materials used in dental-implants and its biological compatibility.

Authors:  Xiaofeng Pang; Yong Huang
Journal:  J Nanosci Nanotechnol       Date:  2012-02

6.  Evaluation of stress distribution in bone of different densities using different implant designs: a three-dimensional finite element analysis.

Authors:  K Premnath; J Sridevi; N Kalavathy; Prakash Nagaranjani; M Ranganath Sharmila
Journal:  J Indian Prosthodont Soc       Date:  2012-10-26

7.  Analysis of the surface deformation of dental implants submitted to pullout and insertion test.

Authors:  Mariana Lima da Costa Valente; Antonio Carlos Shimano; Carla Rodrigues Mazzo; César Penazzo Lepri; Andréa Cândido dos Reis
Journal:  Indian J Dent Res       Date:  2014 Jan-Feb

8.  A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score.

Authors:  Manisha Herekar; Megha Sethi; Tousif Ahmad; Aquaviva Sebasteao Fernandes; Viraj Patil; Harish Kulkarni
Journal:  J Prosthet Dent       Date:  2014-04-14       Impact factor: 3.426

9.  Secondary stability of microthickness hydroxyapatite-coated dental implants installed without primary stability in dogs.

Authors:  Ui-Won Jung; Sungtae Kim; In-Kyeong Lee; Min-Soo Kim; Jung-Seok Lee; Hee-Jin Kim
Journal:  Clin Oral Implants Res       Date:  2013-07-04       Impact factor: 5.977

10.  Comparison of implant stability after different implant surface treatments in dog bone.

Authors:  Sun-Jong Kim; Myung-Rae Kim; Jae-Suk Rim; Sung-Min Chung; Sang-Wan Shin
Journal:  J Appl Oral Sci       Date:  2010 Jul-Aug       Impact factor: 2.698

View more
  3 in total

1.  Immediate non-submerged implants with laser-microtextured collar placed in the inter-radicular septum of mandibular molar extraction sockets associated to GBR: Results at 3-year.

Authors:  Renzo Guarnieri; Dario Di Nardo; Gianni Di Giorgio; Gabriele Miccoli; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2020-04-01

2.  Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Vittoria Perrotti; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Dent J (Basel)       Date:  2019-03-05

3.  One-stage laser-microtextured implants immediately placed in the inter-radicular septum of molar fresh extraction sockets associated with GBR technique. A case series study.

Authors:  Renzo Guarnieri; Dario Di Nardo; Gianfranco Gaimari; Gabriele Miccoli; Luca Testarelli
Journal:  J Clin Exp Dent       Date:  2018-10-01
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.