Abstract

OBJECTIVES: The study presented was designed to analyse the mechanical performance and the primary and secondary stability characteristics of endosseous titanium implants with 1 degree (EXP1) and 2 degrees (EXP2) of taper when compared with the standard Brånemark design (Nobel Biocare AB, Gothenburg, Sweden).
MATERIALS AND METHODS: One pair of 10 mm EXP1 and control implants were placed in the femoral condyles of six rabbits. Paired 6 mm EXP1 and control implants and 6 mm EXP2 and control implants were placed in the tibial metaphysis. The control implants used were 4 mm diameter standard Brånemark implants, the same length as the test implants. At placement, insertion torque (IT) and resonance frequency analysis (RFA) measurements were performed. Six weeks postoperatively when the animals were killed, RFA and removal torque (RT) measurements were made.
RESULTS: At placement, significantly higher IT was needed to insert the EXP implants compared with the controls. RFA values were significantly higher for EXP1 implants placed in the tibia but not in the femur. In pooling data from the femur and tibia there was a significant difference. The EXP2 implants failed to insert fully and demonstrated a lower RFA value than may have been expected due to the exposed threads, although this difference was not statistically significant.
CONCLUSIONS: The results from the present study showed that 1 degrees of taper results in a better primary stability compared with the standard Brånemark design. There was no evidence that the tapered design caused negative bone tissue reactions. All the implants gained in stability during the healing period.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15248883     DOI: 10.1111/j.1600-0501.2004.01041.x

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  29 in total

1.  The effect of implant shape and bone preparation on primary stability.

Authors:  Sang-Hyun Moon; Heung-Sik Um; Jae-Kwan Lee; Beom-Seok Chang; Min-Ku Lee
Journal:  J Periodontal Implant Sci       Date:  2010-10-31       Impact factor: 2.614

2.  Evaluation of dental implant insertion torque using a manual ratchet.

Authors:  M M Goswami; Mukul Kumar; Abhinav Vats; A S Bansal
Journal:  Med J Armed Forces India       Date:  2013-09-24

3.  Clinical study on the primary stability of two dental implant systems with resonance frequency analysis.

Authors:  Annette Rabel; Steffen Gerhard Köhler; Andrea Maria Schmidt-Westhausen
Journal:  Clin Oral Investig       Date:  2007-03-31       Impact factor: 3.573

Review 4.  Role of primary stability for successful osseointegration of dental implants: Factors of influence and evaluation.

Authors:  Fawad Javed; Hameeda Bashir Ahmed; Roberto Crespi; Georgios E Romanos
Journal:  Interv Med Appl Sci       Date:  2013-12-20

5.  Comparative assessment of the interfacial soft and hard tissues investing implants and natural teeth in the macaque mandible.

Authors:  Chong Huat Siar; Chooi Gait Toh; Georgios E Romanos; Kok Han Ng
Journal:  Clin Oral Investig       Date:  2014-11-21       Impact factor: 3.573

6.  Template-guided vs. non-guided drilling in site preparation of dental implants.

Authors:  Uta Scherer; Marcus Stoetzer; Martin Ruecker; Nils-Claudius Gellrich; Constantin von See
Journal:  Clin Oral Investig       Date:  2014-10-30       Impact factor: 3.573

7.  A stepwise under-prepared osteotomy technique improves primary stability in shallow-placed implants: a preliminary study for simultaneous vertical ridge augmentation.

Authors:  Daisuke Ueno; Kei Nakamura; Kousuke Kojima; Takeshi Toyoshima; Hideaki Tanaka; Kazuhiko Ueda; Kiyoshi Koyano; Toshiro Kodama
Journal:  Odontology       Date:  2017-08-02       Impact factor: 2.634

8.  Mechanical properties of self-drilling orthodontic micro-implants with different diameters.

Authors:  Yan Chen; Hee Moon Kyung; Limin Gao; Won-Jae Yu; Eun-Ju Bae; Sang-Min Kim
Journal:  Angle Orthod       Date:  2010-09       Impact factor: 2.079

Review 9.  Post extractive implant: evaluation of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27

Review 10.  Immediate loading implants: review of the critical aspects.

Authors:  L Tettamanti; C Andrisani; M Andreasi Bassi; R Vinci; J Silvestre-Rangil; A Tagliabue
Journal:  Oral Implantol (Rome)       Date:  2017-09-27
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.