Literature DB >> 17393139

Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients.

Marc Feissel1, Jean-Louis Teboul, Paolo Merlani, Julio Badie, Jean-Pierre Faller, Karim Bendjelid.   

Abstract

OBJECTIVES: In septic patients, reliable non-invasive predictors of fluid responsiveness are needed. We hypothesised that the respiratory changes in the amplitude of the plethysmographic pulse wave (DeltaP(PLET)) would allow the prediction of changes in cardiac index following volume administration in mechanically ventilated septic patients.
DESIGN: Prospective clinical investigation.
SETTING: An 11-bed hospital medical intensive care unit. PATIENTS: Twenty-three deeply sedated septic patients mechanically ventilated with tidal volume >or=8 ml/kg and equipped with an arterial catheter and a pulse oximetry plethysmographic sensor.
INTERVENTIONS: Respiratory changes in pulse pressure (DeltaPP), DeltaP(PLET) and cardiac index (transthoracic Doppler echocardiography) were determined before and after volume infusion of colloids (8 ml/kg).
MEASUREMENTS AND MAIN RESULTS: Twenty-eight volume challenges were performed in 23 patients. Before volume expansion, DeltaPP correlated with DeltaP(PLET) (r2 = 0.71, p<0.001). Changes in cardiac index after volume expansion significantly (p<0.001) correlated with baseline DeltaPP (r2 = 0.76) and DeltaP(PLET) (r2 = 0.50). The patients were defined as responders to fluid challenge when cardiac index increased by at least 15% after the fluid challenge. Such an event occurred 18 times. Before volume challenge, a DeltaPP value of 12% and a DeltaP(PLET) value of 14% allowed discrimination between responders and non-responders with sensitivity of 100% and 94% respectively and specificity of 70% and 80% respectively. Comparison of areas under the receiver operator characteristic curves showed that DeltaPP and DeltaP(PLET) predicted similarly fluid responsiveness.
CONCLUSION: The present study found DeltaP(PLET) to be as accurate as DeltaPP for predicting fluid responsiveness in mechanically ventilated septic patients.

Entities:  

Mesh:

Year:  2007        PMID: 17393139     DOI: 10.1007/s00134-007-0602-6

Source DB:  PubMed          Journal:  Intensive Care Med        ISSN: 0342-4642            Impact factor:   17.440


  24 in total

1.  Pulse oximetry plethysmographic waveform during changes in blood volume.

Authors:  M Shamir; L A Eidelman; Y Floman; L Kaplan; R Pizov
Journal:  Br J Anaesth       Date:  1999-02       Impact factor: 9.166

Review 2.  Principles of pulse oximetry: theoretical and practical considerations.

Authors:  C M Alexander; L E Teller; J B Gross
Journal:  Anesth Analg       Date:  1989-03       Impact factor: 5.108

3.  Analysis of the ear pulse oximeter waveform.

Authors:  Aymen A Awad; Robert G Stout; M Ashraf M Ghobashy; Hoda A Rezkanna; David G Silverman; Kirk H Shelley
Journal:  J Clin Monit Comput       Date:  2006-04-13       Impact factor: 2.502

4.  Increased intra-abdominal pressure affects respiratory variations in arterial pressure in normovolaemic and hypovolaemic mechanically ventilated healthy pigs.

Authors:  Serge Duperret; Franck Lhuillier; Vincent Piriou; Emmanuel Vivier; Olivier Metton; Patricia Branche; Guy Annat; Karim Bendjelid; Jean Paul Viale
Journal:  Intensive Care Med       Date:  2006-11-11       Impact factor: 17.440

5.  Arterial-pulse oximetry loops: a new method of monitoring vascular tone.

Authors:  K H Shelley; W B Murray; D Chang
Journal:  J Clin Monit       Date:  1997-07

6.  Reliability of the thermodilution method in the determination of cardiac output in clinical practice.

Authors:  C W Stetz; R G Miller; G E Kelly; T A Raffin
Journal:  Am Rev Respir Dis       Date:  1982-12

7.  A method of comparing the areas under receiver operating characteristic curves derived from the same cases.

Authors:  J A Hanley; B J McNeil
Journal:  Radiology       Date:  1983-09       Impact factor: 11.105

8.  Stroke volume variations for assessment of cardiac responsiveness to volume loading in mechanically ventilated patients after cardiac surgery.

Authors:  Daniel A Reuter; Thomas W Felbinger; Christian Schmidt; Erich Kilger; Oliver Goedje; Peter Lamm; Alwin E Goetz
Journal:  Intensive Care Med       Date:  2002-03-20       Impact factor: 17.440

9.  Pulse pressure variations to predict fluid responsiveness: influence of tidal volume.

Authors:  Daniel De Backer; Sarah Heenen; Michael Piagnerelli; Marc Koch; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2005-03-08       Impact factor: 17.440

10.  Pulse oximeter as a sensor of fluid responsiveness: do we have our finger on the best solution?

Authors:  Xavier Monnet; Bouchra Lamia; Jean-Louis Teboul
Journal:  Crit Care       Date:  2005-09-28       Impact factor: 9.097

View more
  37 in total

1.  Reliability of Continuous Non-Invasive Assessment of Hemoglobin and Fluid Responsiveness: Impact of Obesity and Abdominal Insufflation Pressures.

Authors:  Mia DeBarros; Marlin W Causey; Patrick Chesley; Matthew Martin
Journal:  Obes Surg       Date:  2015-07       Impact factor: 4.129

Review 2.  Accuracy of plethysmographic indices as predictors of fluid responsiveness in mechanically ventilated adults: a systematic review and meta-analysis.

Authors:  Claudio Sandroni; Fabio Cavallaro; Cristina Marano; Chiara Falcone; Paolo De Santis; Massimo Antonelli
Journal:  Intensive Care Med       Date:  2012-06-26       Impact factor: 17.440

Review 3.  Pulse pressure variation: where are we today?

Authors:  Maxime Cannesson; Mateo Aboy; Christoph K Hofer; Mohamed Rehman
Journal:  J Clin Monit Comput       Date:  2011-02       Impact factor: 2.502

4.  Comment on "Plethysmographic dynamic indices predict fluid responsiveness in septic ventilated patients" by Feissel et al.

Authors:  Maxime Cannesson; Olivier Desebbe; Jean-Jacques Lehot
Journal:  Intensive Care Med       Date:  2007-07-28       Impact factor: 17.440

Review 5.  Year in review in Intensive Care Medicine, 2007. II. Haemodynamics, pneumonia, infections and sepsis, invasive and non-invasive mechanical ventilation, acute respiratory distress syndrome.

Authors:  Massimo Antonelli; Elie Azoulay; Marc Bonten; Jean Chastre; Giuseppe Citerio; Giorgio Conti; Daniel De Backer; François Lemaire; Herwig Gerlach; Johan Groeneveld; Goran Hedenstierna; Duncan Macrae; Jordi Mancebo; Salvatore M Maggiore; Alexandre Mebazaa; Philipp Metnitz; Jerme Pugin; Jan Wernerman; Haibo Zhang
Journal:  Intensive Care Med       Date:  2008-01-31       Impact factor: 17.440

Review 6.  Interactions between respiration and systemic hemodynamics. Part II: practical implications in critical care.

Authors:  François Feihl; Alain F Broccard
Journal:  Intensive Care Med       Date:  2008-09-30       Impact factor: 17.440

7.  Impact of skin incision on the pleth variability index.

Authors:  Masaharu Takeyama; Akira Matsunaga; Yasuyuki Kakihana; Mina Masuda; Tamotsu Kuniyoshi; Yuichi Kanmura
Journal:  J Clin Monit Comput       Date:  2011-09-18       Impact factor: 2.502

8.  Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status.

Authors:  Raphaël Giraud; Nils Siegenthaler; Denis R Morel; Jacques-A Romand; Laurent Brochard; Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2012-11-02       Impact factor: 2.502

9.  Recent advances in pulse oximetry.

Authors:  Maxime Cannesson; Pekka Talke
Journal:  F1000 Med Rep       Date:  2009-08-26

10.  Pulse pressure variation and volume responsiveness during acutely increased pulmonary artery pressure: an experimental study.

Authors:  Fritz Daudel; David Tüller; Stefanie Krähenbühl; Stephan M Jakob; Jukka Takala
Journal:  Crit Care       Date:  2010-06-24       Impact factor: 9.097

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.