Reliability of the thermodilution method in the determination of cardiac output in clinical practice.

C W Stetz, R G Miller, G E Kelly, T A Raffin.   

Abstract

The thermodilution (TD) method of determining cardiac output (CO) is widely used in clinical practice, but its reliability in this setting is not well understood and may be poor. This is especially true when dealing with unstable patients and using commercial TD devices. Numerous published reports have shown markedly variable results when comparing simultaneously the TD method and the Fick or dye-dilution methods in catheterization laboratories, intensive care units, or operating rooms. In order to assist clinicians in interpreting the reliability of the TD method in measuring CO, we analyzed all available published data (14 reports). The differing results in these reports were evaluated by standard statistical methods and by an extension of the influence function method of structural analysis developed to differentiate reproducibility and accuracy errors of each technique. Comparing the accuracy of the TD method with that of the Fick or the dye-dilution methods reveals that the 3 methods are of equal merit and can be used as independent references. Our reproducibility data show that when using commercial TD devices there must be a minimal difference of 12 to 15% (average, 13%) between determinations of cardiac output (3 measurements per determination) to suggest clinical significance. Minimal differences of 20 to 26% (average, 22%) are required between determinations when using 1 measurement per determination. There was no difference in the quality of the TD method when comparing rapid injection of iced or room temperature thermal indicator.

Entities:  

Mesh:

Year:  1982        PMID: 6758640     DOI: 10.1164/arrd.1982.126.6.1001

Source DB:  PubMed          Journal:  Am Rev Respir Dis        ISSN: 0003-0805


  88 in total

1.  A meta-analysis of studies using bias and precision statistics to compare cardiac output measurement techniques.

Authors:  L A Critchley; J A Critchley
Journal:  J Clin Monit Comput       Date:  1999-02       Impact factor: 2.502

2.  Partial CO2 rebreathing cardiac output--operating principles of the NICO system.

Authors:  M B Jaffe
Journal:  J Clin Monit Comput       Date:  1999-08       Impact factor: 2.502

3.  An adequate strategy for the thermodilution technique in patients during mechanical ventilation.

Authors:  J R Jansen; J J Schreuder; J J Settels; J J Kloek; A Versprille
Journal:  Intensive Care Med       Date:  1990       Impact factor: 17.440

Review 4.  European Society of Intensive Care Medicine. Expert panel: the use of the pulmonary artery catheter.

Authors: 
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

Review 5.  Continuous and less invasive central hemodynamic monitoring by blood pressure waveform analysis.

Authors:  Ramakrishna Mukkamala; Da Xu
Journal:  Am J Physiol Heart Circ Physiol       Date:  2010-07-09       Impact factor: 4.733

Review 6.  Reproducibility of transpulmonary thermodilution cardiac output measurements in clinical practice: a systematic review.

Authors:  Raphaël Giraud; Nils Siegenthaler; Paolo Merlani; Karim Bendjelid
Journal:  J Clin Monit Comput       Date:  2016-01-11       Impact factor: 2.502

7.  Continuous cardiac output measurement by un-calibrated pulse wave analysis and pulmonary artery catheter in patients with septic shock.

Authors:  Michael T Ganter; Jamal A Alhashemi; Adel M Al-Shabasy; Ursina M Schmid; Peter Schott; Sanaa A Shalabi; Ahmed M Badri; Sonja Hartnack; Christoph K Hofer
Journal:  J Clin Monit Comput       Date:  2015-02-27       Impact factor: 2.502

8.  Ultrasound dilution: an accurate means of determining cardiac output in children.

Authors:  Ivory Crittendon; William J Dreyer; Jamie A Decker; Jeffrey J Kim
Journal:  Pediatr Crit Care Med       Date:  2012-01       Impact factor: 3.624

9.  Determination of cardiac output by an angle and diameter independent dual beam Doppler technique in critically ill infants.

Authors:  C F Wippermann; D Schranz; R Huth; F Zepp; H Oelert; B K Jüngst
Journal:  Br Heart J       Date:  1992-02

10.  Thermal dye double indicator dilution measurement of lung water in man: comparison with gravimetric measurements.

Authors:  F G Mihm; T W Feeley; S W Jamieson
Journal:  Thorax       Date:  1987-01       Impact factor: 9.139

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.