BACKGROUND: During surgery, proper fluid resuscitation and hemostatic control is critical. Pleth variability index (PVI) is advocated as a reliable way of optimizing intraoperative fluid resuscitation. PVI is a measure of dynamic change in perfusion index during a complete respiratory cycle. Non-invasive monitoring of total hemoglobin could provide a reliable means to determine need for transfusion. We analyzed the impact of insufflation and obesity on non-invasive measurements of hemoglobin and PVI in laparoscopic procedures to validate reliability of fluid responsiveness and hemoglobin levels.
METHODS: A non-invasive hemoglobin and PVI monitoring device was prospectively analyzed in patients undergoing abdominal operations. Patients were stratified by open and laparoscopic approach and obesity (body mass index (BMI) ≥35). PVI and hemoglobin values were assessed before, during, and after insufflation and compared to control patients undergoing open surgery.
RESULTS: Sixty-three patients were enrolled (mean age 42 years; 71 % male; mean BMI 36) with 24 patients laparoscopic non-obese (LNO), 20 laparoscopic obese (LO), and 19 undergoing open operations. There was no significant blood loss. Hemoglobin did not change significantly before or after insufflation. There was false elevation of PVI with insufflation and more pronounced in obese patients.
CONCLUSIONS: Insufflation or obesity was not associated with significant variations in hemoglobin. Non-invasive monitoring of hemoglobin is useful in laparoscopic procedures in obese and non-obese patients. PVI values should be used cautiously during laparoscopic procedures, particularly in obese patients.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25399349     DOI: 10.1007/s11695-014-1505-6

Source DB:  PubMed          Journal:  Obes Surg        ISSN: 0960-8923            Impact factor:   4.129


  28 in total

1.  Central venous access in morbidly obese patients.

Authors:  Paul Jefferson; David R Ball
Journal:  Anesth Analg       Date:  2002-09       Impact factor: 5.108

2.  Dynamic variables of fluid responsiveness during pneumoperitoneum and laparoscopic surgery.

Authors:  L Ø Høiseth; I E Hoff; K Myre; S A Landsverk; K A Kirkebøen
Journal:  Acta Anaesthesiol Scand       Date:  2012-01-31       Impact factor: 2.105

3.  Pleth variability index to monitor the respiratory variations in the pulse oximeter plethysmographic waveform amplitude and predict fluid responsiveness in the operating theatre.

Authors:  M Cannesson; O Desebbe; P Rosamel; B Delannoy; J Robin; O Bastien; J-J Lehot
Journal:  Br J Anaesth       Date:  2008-06-02       Impact factor: 9.166

4.  Volume and outcome relationship in bariatric surgery in the laparoscopic era.

Authors:  Mehraneh D Jafari; Fariba Jafari; Monica T Young; Brian R Smith; Michael J Phalen; Ninh T Nguyen
Journal:  Surg Endosc       Date:  2013-08-13       Impact factor: 4.584

Review 5.  How monitoring of the microcirculation may help us at the bedside.

Authors:  Colin Verdant; Daniel De Backer
Journal:  Curr Opin Crit Care       Date:  2005-06       Impact factor: 3.687

Review 6.  Does central venous pressure predict fluid responsiveness? A systematic review of the literature and the tale of seven mares.

Authors:  Paul E Marik; Michael Baram; Bobbak Vahid
Journal:  Chest       Date:  2008-07       Impact factor: 9.410

7.  The enhanced recovery after surgery (ERAS) pathway for patients undergoing colorectal surgery: an update of meta-analysis of randomized controlled trials.

Authors:  Liang Lv; Yong-Fang Shao; Yan-bing Zhou
Journal:  Int J Colorectal Dis       Date:  2012-09-22       Impact factor: 2.571

8.  Intraoperative crystalloid overload leads to substantial inflammatory infiltration of intestinal anastomoses-a histomorphological analysis.

Authors:  Birte Kulemann; Sylvia Timme; Gabriel Seifert; Philipp A Holzner; Torben Glatz; Olivia Sick; Sophia Chikhladze; Peter Bronsert; Jens Hoeppner; Martin Werner; Ulrich T Hopt; Goran Marjanovic
Journal:  Surgery       Date:  2013-07-19       Impact factor: 3.982

Review 9.  Evidence-based review of the use of the pulmonary artery catheter: impact data and complications.

Authors:  Mehrnaz Hadian; Michael R Pinsky
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

10.  Effect of fluid resuscitation on mortality and organ function in experimental sepsis models.

Authors:  Sebastian Brandt; Tomas Regueira; Hendrik Bracht; Francesca Porta; Siamak Djafarzadeh; Jukka Takala; José Gorrasi; Erika Borotto; Vladimir Krejci; Luzius B Hiltebrand; Lukas E Bruegger; Guido Beldi; Ludwig Wilkens; Philipp M Lepper; Ulf Kessler; Stephan M Jakob
Journal:  Crit Care       Date:  2009-11-23       Impact factor: 9.097

View more
  2 in total

1.  Pleth variability index and respiratory system compliance to direct PEEP settings in mechanically ventilated patients, an exploratory study.

Authors:  Jing Zhou; Yi Han
Journal:  Springerplus       Date:  2016-08-20

Review 2.  Intraoperative Monitoring of the Obese Patient Undergoing Surgery: A Narrative Review.

Authors:  Andrea P Haren; Shrijit Nair; Maria C Pace; Pasquale Sansone
Journal:  Adv Ther       Date:  2021-06-05       Impact factor: 3.845