Literature DB >> 23117586

Respiratory change in ECG-wave amplitude is a reliable parameter to estimate intravascular volume status.

Raphaël Giraud1, Nils Siegenthaler, Denis R Morel, Jacques-A Romand, Laurent Brochard, Karim Bendjelid.   

Abstract

Electrocardiogram (ECG) is a standard type of monitoring in intensive care medicine. Several studies suggest that changes in ECG morphology may reflect changes in volume status. The "Brody effect", a theoretical analysis of left ventricular (LV) chamber size influence on QRS-wave amplitude, is the key element of this phenomenon. It is characterised by an increase in QRS-wave amplitude that is induced by an increase in ventricular preload. This study investigated the influence of changes in intravascular volume status on respiratory variations of QRS-wave amplitudes (ΔECG) compared with respiratory pulse pressure variations (ΔPP), considered as a reference standard. In 17 pigs, ECG and arterial pressure were recorded. QRS-wave amplitude was measured from the Biopac recording to ensure that in all animals ECG electrodes were always at the same location. Maximal QRS amplitude (ECGmax) and minimal QRS amplitude (ECGmin) were determined over one respiratory cycle. ΔECG was calculated as 100 × [(ECGmax - ECGmin)/(ECGmax + ECGmin)/2]. ΔECG and ΔPP were simultaneously recorded. Measurements were performed at different time points: during normovolemic conditions, after haemorrhage (25 mL/kg), and following re-transfusion (25 mL/kg) with constant tidal volume (10 mL/kg) and respiration rate (15 breath/min). At baseline, ΔPP and ΔECG were both <12 %. ΔPP were significantly correlated with ΔECG (r(2) = 0.89, p < 0.001). Volume loss induced by haemorrhage increased significantly ΔPP and ΔECG. Moreover, during this state, ΔPP were significantly correlated with ΔECG (r(2) = 0.86, p < 0.001). Re-transfusion significantly decreased ΔPP and ΔECG, and ΔPP were significantly correlated with ΔECG (r(2) = 0.90, p < 0.001). The observed correlations between ΔPP and ΔECG at each time point of the study suggest that ΔECG is a reliable parameter to estimate the changes in intravascular volume status and provide experimental confirmation of the "Brody effect."

Entities:  

Mesh:

Year:  2012        PMID: 23117586     DOI: 10.1007/s10877-012-9405-6

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  22 in total

1.  Relations between respiratory changes in R-wave amplitude and arterial pulse pressure in mechanically ventilated patients.

Authors:  Maxime Cannesson; Geoffray Keller; Olivier Desebbe; Jean-Jacques Lehot
Journal:  J Clin Monit Comput       Date:  2010-05-11       Impact factor: 2.502

Review 2.  Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care.

Authors:  Karim Bendjelid; Jacques-A Romand
Journal:  Intensive Care Med       Date:  2003-01-21       Impact factor: 17.440

3.  The diagnosis of pericardial effusion and cardiac tamponade by 12-lead ECG. A technology assessment.

Authors:  M J Eisenberg; L M de Romeral; P A Heidenreich; N B Schiller; G T Evans
Journal:  Chest       Date:  1996-08       Impact factor: 9.410

Review 4.  Clinical trials of monitoring in anaesthesia, critical care and acute ward care: a review.

Authors:  D Young; J Griffiths
Journal:  Br J Anaesth       Date:  2006-05-12       Impact factor: 9.166

5.  The relationship between exercise-induced R wave amplitude changes and QRS vector loops.

Authors:  K Watanabe; V Bhargava; V F Froelicher
Journal:  J Electrocardiol       Date:  1981       Impact factor: 1.438

6.  Increase in R-wave amplitude during transient epicardial injury (Prinzmetal type).

Authors:  E C Schick; D A Weiner; W B Hood; T J Ryan
Journal:  J Electrocardiol       Date:  1980       Impact factor: 1.438

7.  Clinical use of respiratory changes in arterial pulse pressure to monitor the hemodynamic effects of PEEP.

Authors:  F Michard; D Chemla; C Richard; M Wysocki; M R Pinsky; Y Lecarpentier; J L Teboul
Journal:  Am J Respir Crit Care Med       Date:  1999-03       Impact factor: 21.405

8.  Changes in R-Wave amplitude in DII lead is less sensitive than pulse pressure variation to detect changes in stroke volume after fluid challenge in ICU patients postoperatively to cardiac surgery.

Authors:  Christophe Soltner; Romain Dantec; Frédéric Lebreton; Julien Huntzinger; Laurent Beydon
Journal:  J Clin Monit Comput       Date:  2010-02-04       Impact factor: 2.502

9.  The respiratory variation in inferior vena cava diameter as a guide to fluid therapy.

Authors:  Marc Feissel; Frédéric Michard; Jean-Pierre Faller; Jean-Louis Teboul
Journal:  Intensive Care Med       Date:  2004-03-25       Impact factor: 17.440

10.  Pulse pressure variation, stroke volume variation and dynamic arterial elastance.

Authors:  Raphael Giraud; Nils Siegenthaler; Karim Bendjelid
Journal:  Crit Care       Date:  2011-03-23       Impact factor: 9.097

View more
  4 in total

1.  New analyses of standard physiological signals: the old pipes give the sweetest smoke.

Authors:  Joseph Rinehart; Maxime Cannesson
Journal:  J Clin Monit Comput       Date:  2013-04       Impact factor: 2.502

2.  A new modality for the estimation of corrected flow time via electrocardiography as an alternative to Doppler ultrasonography.

Authors:  Hooman Hossein-Nejad; Payam Mohammadinejad; Atefeh Zeinoddini; Seyedhossein Seyedhosseini Davarani; Mohsen Banaie
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-04-22       Impact factor: 1.468

3.  Preoperative "R wave amplitude variation" on electrocardiogram predicts severe hypovolemia.

Authors:  Sohan Lal Solanki; Pooja P Kumar; Reshma P Ambulkar
Journal:  Ann Card Anaesth       Date:  2019 Jul-Sep

4.  The PCQP Score for Volume Status of Acutely Ill Patients: Integrating Vascular Pedicle Width, Caval Index, Respiratory Variability of the QRS Complex and R Wave Amplitude.

Authors:  Ali Taghizadieh; Kavous Shahsavari Nia; Payman Moharramzadeh; Mahboob Pouraghaei; Atefeh Ghavidel; Zahra Parsian; Ata Mahmoodpoor
Journal:  Indian J Crit Care Med       Date:  2017-11
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.