Literature DB >> 17388186

Spread-out Bragg peak and monitor units calculation with the Monte Carlo code MCNPX.

J Hérault1, N Iborra, B Serrano, P Chauvel.   

Abstract

The aim of this work was to study the dosimetric potential of the Monte Carlo code MCNPX applied to the protontherapy field. For series of clinical configurations a comparison between simulated and experimental data was carried out, using the proton beam line of the MEDICYC isochronous cyclotron installed in the Centre Antoine Lacassagne in Nice. The dosimetric quantities tested were depth-dose distributions, output factors, and monitor units. For each parameter, the simulation reproduced accurately the experiment, which attests the quality of the choices made both in the geometrical description and in the physics parameters for beam definition. These encouraging results enable us today to consider a simplification of quality control measurements in the future. Monitor Units calculation is planned to be carried out with preestablished Monte Carlo simulation data. The measurement, which was until now our main patient dose calibration system, will be progressively replaced by computation based on the MCNPX code. This determination of Monitor Units will be controlled by an independent semi-empirical calculation.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17388186     DOI: 10.1118/1.2431473

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  12 in total

1.  Adjustment of the lateral and longitudinal size of scanned proton beam spots using a pre-absorber to optimize penumbrae and delivery efficiency.

Authors:  Uwe Titt; Dragan Mirkovic; Gabriel O Sawakuchi; Luis A Perles; Wayne D Newhauser; Phillip J Taddei; Radhe Mohan
Journal:  Phys Med Biol       Date:  2010-11-12       Impact factor: 3.609

2.  Range and modulation dependencies for proton beam dose per monitor unit calculations.

Authors:  Wen C Hsi; Andries N Schreuder; Michael F Moyers; Chris E Allgower; Jonathan B Farr; Anthony E Mascia
Journal:  Med Phys       Date:  2009-02       Impact factor: 4.071

3.  Monte Carlo calculations and measurements of absorbed dose per monitor unit for the treatment of uveal melanoma with proton therapy.

Authors:  Nicholas Koch; Wayne D Newhauser; Uwe Titt; Dan Gombos; Kevin Coombes; George Starkschall
Journal:  Phys Med Biol       Date:  2008-02-25       Impact factor: 3.609

4.  Effective Dose from Stray Radiation for a Patient Receiving Proton Therapy for Liver Cancer.

Authors:  Phillip J Taddei; Sunil Krishnan; Dragan Mirkovic; Pablo Yepes; Wayne D Newhauser
Journal:  AIP Conf Proc       Date:  2009-03-10

5.  Reducing stray radiation dose to patients receiving passively scattered proton radiotherapy for prostate cancer.

Authors:  Phillip J Taddei; Jonas D Fontenot; Yuanshui Zheng; Dragan Mirkovic; Andrew K Lee; Uwe Titt; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2008-03-27       Impact factor: 3.609

6.  Development and verification of an analytical algorithm to predict absorbed dose distributions in ocular proton therapy using Monte Carlo simulations.

Authors:  Nicholas C Koch; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2010-01-14       Impact factor: 3.609

7.  The risk of developing a second cancer after receiving craniospinal proton irradiation.

Authors:  Wayne D Newhauser; Jonas D Fontenot; Anita Mahajan; David Kornguth; Marilyn Stovall; Yuanshui Zheng; Phillip J Taddei; Dragan Mirkovic; Radhe Mohan; James D Cox; Shiao Woo
Journal:  Phys Med Biol       Date:  2009-03-20       Impact factor: 3.609

8.  Stray radiation dose and second cancer risk for a pediatric patient receiving craniospinal irradiation with proton beams.

Authors:  Phillip J Taddei; Dragan Mirkovic; Jonas D Fontenot; Annelise Giebeler; Yuanshui Zheng; David Kornguth; Radhe Mohan; Wayne D Newhauser
Journal:  Phys Med Biol       Date:  2009-03-20       Impact factor: 3.609

9.  Design of spread-out Bragg peaks in hadron therapy with oxygen ions.

Authors:  Ladan Rezaee
Journal:  Rep Pract Oncol Radiother       Date:  2018-09-04

10.  Implementation of an analytical model for leakage neutron equivalent dose in a proton radiotherapy planning system.

Authors:  John Eley; Wayne Newhauser; Kenneth Homann; Rebecca Howell; Christopher Schneider; Marco Durante; Christoph Bert
Journal:  Cancers (Basel)       Date:  2015-03-11       Impact factor: 6.639

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.