Literature DB >> 17333411

Cone-beam micro-CT system based on LabVIEW software.

Ciprian N Ionita1, Keneth R Hoffmann, Daniel R Bednarek, Ravishankar Chityala, Stephen Rudin.   

Abstract

Construction of a cone-beam computed tomography (CBCT) system for laboratory research usually requires integration of different software and hardware components. As a result, building and operating such a complex system require the expertise of researchers with significantly different backgrounds. Additionally, writing flexible code to control the hardware components of a CBCT system combined with designing a friendly graphical user interface (GUI) can be cumbersome and time consuming. An intuitive and flexible program structure, as well as the program GUI for CBCT acquisition, is presented in this note. The program was developed in National Instrument's Laboratory Virtual Instrumentation Engineering Workbench (LabVIEW) graphical language and is designed to control a custom-built CBCT system but has been also used in a standard angiographic suite. The hardware components are commercially available to researchers and are in general provided with software drivers which are LabVIEW compatible. The program structure was designed as a sequential chain. Each step in the chain takes care of one or two hardware commands at a time; the execution of the sequence can be modified according to the CBCT system design. We have scanned and reconstructed over 200 specimens using this interface and present three examples which cover different areas of interest encountered in laboratory research. The resulting 3D data are rendered using a commercial workstation. The program described in this paper is available for use or improvement by other researchers.

Mesh:

Year:  2007        PMID: 17333411      PMCID: PMC2553273          DOI: 10.1007/s10278-007-9024-9

Source DB:  PubMed          Journal:  J Digit Imaging        ISSN: 0897-1889            Impact factor:   4.056


  8 in total

1.  Cone-beam computed tomography with a flat-panel imager: initial performance characterization.

Authors:  D A Jaffray; J H Siewerdsen
Journal:  Med Phys       Date:  2000-06       Impact factor: 4.071

2.  Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

Authors:  J H Siewerdsen; D A Jaffray
Journal:  Med Phys       Date:  2000-08       Impact factor: 4.071

3.  Compact CT/SPECT Small-Animal Imaging System.

Authors:  George A Kastis; Lars R Furenlid; Donald W Wilson; Todd E Peterson; H Bradford Barber; Harrison H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2004-02       Impact factor: 1.679

4.  Vessel motion measurement in real-time using movement detection at multiple regions of interest.

Authors:  Robert Dielenberg; Paul Halasz; Kayoko Hosaka; Dirk van Helden
Journal:  J Neurosci Methods       Date:  2005-09-30       Impact factor: 2.390

5.  A Prototype Micro-Angiographic Fluoroscope and Its Application in Animal Studies.

Authors:  Ye Wu; Stephen Rudin; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2005

6.  Micro-CT with respiratory and cardiac gating.

Authors:  C Badea; L W Hedlund; G A Johnson
Journal:  Med Phys       Date:  2004-12       Impact factor: 4.071

7.  Flow modification in canine intracranial aneurysm model by an asymmetric stent: studies using digital subtraction angiography (DSA) and image-based computational fluid dynamics (CFD) analyses.

Authors:  Yiemeng Hoi; Ciprian N Ionita; Rekha V Tranquebar; Kenneth R Hoffmann; Scott H Woodward; Dale B Taulbee; Hui Meng; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-03-13

8.  Micro-angiography for neuro-vascular imaging. I. Experimental evaluation and feasibility.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann; Iacovos S Kyprianou
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

  8 in total
  15 in total

1.  Region-of-interest cone beam computed tomography (ROI CBCT) with a high resolution CMOS detector.

Authors:  A Jain; H Takemoto; M D Silver; S V S Nagesh; C N Ionita; D R Bednarek; S Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-18

2.  Investigation of Noise and Contrast Sensitivity of an Electron Multiplying Charge-Coupled Device (EMCCD) based Cone Beam Micro-CT System.

Authors:  Sumukh Bysani Krishnakumar; Alexander R Podgorsak; Sv Setlur Nagesh; Amit Jain; Stephen Rudin; Daniel R Bednarek; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-25

3.  Evaluation of a second-generation self-expanding variable-porosity flow diverter in a rabbit elastase aneurysm model.

Authors:  C N Ionita; S K Natarajan; W Wang; L N Hopkins; E I Levy; A H Siddiqui; D R Bednarek; S Rudin
Journal:  AJNR Am J Neuroradiol       Date:  2011-07-14       Impact factor: 3.825

4.  Use of a CMOS-based micro-CT system to validate a ring artifact correction algorithm on low-dose image data.

Authors:  Alexander R Podgorsak; S V Setlur Nagesh; Daniel Bednarek; Stephen Rudin; Ciprian N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-03-09

5.  Micro-Computed tomography (CT) based assessment of dental regenerative therapy in the canine mandible model.

Authors:  P Khobragade; A Jain; S V Setlur Nagesh; S Andreana; R Dziak; S K Sunkara; S Sunkara; D R Bednarek; S Rudin; C N Ionita
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

6.  Segmentation and visualization of a large, high-resolution micro-CT data of mice.

Authors:  Ravishankar Chityala; Sridevi Pudipeddi; Luke Arensten; Susanta Hui
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

7.  Self-calibration of a cone-beam micro-CT system.

Authors:  V Patel; R N Chityala; K R Hoffmann; C N Ionita; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2009-01       Impact factor: 4.071

8.  The asymmetric vascular stent: efficacy in a rabbit aneurysm model.

Authors:  Ciprian N Ionita; Ann M Paciorek; Andreea Dohatcu; Kenneth R Hoffmann; Daniel R Bednarek; John Kolega; Elad I Levy; L Nelson Hopkins; Stephen Rudin; J Duffy Mocco
Journal:  Stroke       Date:  2009-01-08       Impact factor: 7.914

9.  Asymmetric vascular stent: feasibility study of a new low-porosity patch-containing stent.

Authors:  Ciprian N Ionita; Ann M Paciorek; Kenneth R Hoffmann; Daniel R Bednarek; Junichi Yamamoto; John Kolega; Elad I Levy; L Nelson Hopkins; Stephen Rudin; J Mocco
Journal:  Stroke       Date:  2008-04-24       Impact factor: 7.914

10.  Rotational micro-CT using a clinical C-arm angiography gantry.

Authors:  V Patel; K R Hoffmann; C N Ionita; C Keleshis; D R Bednarek; S Rudin
Journal:  Med Phys       Date:  2008-10       Impact factor: 4.071

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.