Optimization of x-ray imaging geometry (with specific application to flat-panel cone-beam computed tomography).

J H Siewerdsen1, D A Jaffray.   

Abstract

A theoretical method is presented that allows identification of optimal x-ray imaging geometry, considering the effects of x-ray source distribution, imaging task, x-ray scatter, and imager detective quantum efficiency (DQE). Each of these factors is incorporated into the ICRU-recommended figure of merit for image quality, the detectability index, which is maximized to determine the optimal system configuration. Cascaded systems analysis of flat-panel imagers (FPIs) is extended to incorporate the effects of x-ray scatter directly in the DQE, showing that x-ray scatter degrades DQE as an additive noise source. Optimal magnification is computed for FPI configurations appropriate to (but not limited to) cone-beam computed tomography (CBCT). The sensitivity of the results is examined as a function of focal spot size, imaging task (e.g., ideal observer detection or discrimination tasks), x-ray scatter fraction, detector resolution, and additive noise. Nominal conditions for FPI-CBCT result in optimal magnification of approximately 1.4-1.6, depending primarily on the magnitude of the x-ray scatter fraction. The methodology is sufficiently general that examination of optimal geometry for other FPI applications (e.g., chest radiography, fluoroscopy, and mammography) is possible. The degree to which increased exposure can be used to compensate for x-ray scatter degradation is quantified.

Mesh:

Year:  2000        PMID: 10984236     DOI: 10.1118/1.1286590

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  52 in total

1.  Antiscatter grids in mobile C-arm cone-beam CT: effect on image quality and dose.

Authors:  S Schafer; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; J H Siewerdsen
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

2.  Scatter correction for full-fan volumetric CT using a stationary beam blocker in a single full scan.

Authors:  Tianye Niu; Lei Zhu
Journal:  Med Phys       Date:  2011-11       Impact factor: 4.071

3.  Evaluation of a cone beam CT artefact reduction algorithm.

Authors:  B Bechara; C A McMahan; H Geha; M Noujeim
Journal:  Dentomaxillofac Radiol       Date:  2012-02-23       Impact factor: 2.419

4.  Task-based modeling and optimization of a cone-beam CT scanner for musculoskeletal imaging.

Authors:  P Prakash; W Zbijewski; G J Gang; Y Ding; J W Stayman; J Yorkston; J A Carrino; J H Siewerdsen
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Beyond noise power in 3D computed tomography: the local NPS and off-diagonal elements of the Fourier domain covariance matrix.

Authors:  Angel R Pineda; Daniel J Tward; Antonio Gonzalez; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2012-06       Impact factor: 4.071

6.  Cone-beam micro-CT system based on LabVIEW software.

Authors:  Ciprian N Ionita; Keneth R Hoffmann; Daniel R Bednarek; Ravishankar Chityala; Stephen Rudin
Journal:  J Digit Imaging       Date:  2007-02-28       Impact factor: 4.056

7.  A Statistical Model for Rigid Image Registration Performance: The Influence of Soft-Tissue Deformation as a Confounding Noise Source.

Authors:  Michael D Ketcha; Tharindu De Silva; Runze Han; Ali Uneri; Sebastian Vogt; Gerhard Kleinszig; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2019-03-27       Impact factor: 10.048

8.  Computer modeling of the spatial resolution properties of a dedicated breast CT system.

Authors:  Kai Yang; Alexander L C Kwan; John M Boone
Journal:  Med Phys       Date:  2007-06       Impact factor: 4.071

Review 9.  Current status and new horizons in Monte Carlo simulation of X-ray CT scanners.

Authors:  Habib Zaidi; Mohammad Reza Ay
Journal:  Med Biol Eng Comput       Date:  2007-07-05       Impact factor: 2.602

10.  Experimental study of intracranial hematoma detection with flat panel detector C-arm CT.

Authors:  H Arakawa; M P Marks; H M Do; D M Bouley; N Strobel; T Moore; R Fahrig
Journal:  AJNR Am J Neuroradiol       Date:  2008-01-17       Impact factor: 3.825

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.