Literature DB >> 21311727

A Prototype Micro-Angiographic Fluoroscope and Its Application in Animal Studies.

Ye Wu1, Stephen Rudin, Daniel R Bednarek.   

Abstract

In order to satisfy the high resolution (3 to 10 cycles/mm) imaging requirements in neurovascular image-guided interventional (IGI) procedures, a micro-angiographic fluoroscope (MAF) is being developed to enable both rapid sequence angiography (15 fps) at high exposure levels (hundreds of μR/frame) as well as fluoroscopy at high frame rates (30 fps) and low exposure levels (5 to 20 μR/frame). The prototype MAF consists of a 350-μm-thick CsI(Tl) scintillator coupled by a 2:1 fiber-optical taper to an 18 mm diameter variable-gain light image intensifier with two-stage microchannel plate (MCP) viewed by a 12-bit, 1024x1024, 30 fps CCD camera with digital interface board. The optical set-up enables variation of effective pixel-size from 31 to 50 micron. The first frame lag of the MAF in fluoroscopic 30 fps mode (2:1 binning) was less than 0.8% at exposures of 5-23 μR/frame. MTF, NPS, and DQE in angiographic mode were measured for IEC standard spectrum RQA 5. At spatial frequencies of 4 and 10 cycles/mm the MTF was 14% and 1.5%, and the DQE was 12% and 1.2%, respectively, while the DQE(0) was 60%. Acquisition software was developed to acquire 15 fps angiography and 30 fps fluoroscopy for real-time dark field and flat field correction or real-time roadmapping. Images obtained with the MAF in small animal IGI procedures are demonstrated. The linearity versus x-ray intensity and MCP working range effects has been studied. We plan to expand the current 3.6 cm diameter field of view to 6 cm in the next model of the MAF.

Entities:  

Year:  2005        PMID: 21311727      PMCID: PMC3035319          DOI: 10.1117/12.589232

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  6 in total

1.  Use of a slit camera for MTF measurements.

Authors:  C D Bradford; W W Peppler; J M Waidelich
Journal:  Med Phys       Date:  1999-11       Impact factor: 4.071

2.  Scanning-slit photon counting x-ray imaging system using a microchannel plate detector.

Authors:  Polad M Shikhaliev; Tong Xu; Huy Le; Sabee Molloi
Journal:  Med Phys       Date:  2004-05       Impact factor: 4.071

3.  Solid-state fluoroscopic imager for high-resolution angiography: physical characteristics of an 8 cm x 8 cm experimental prototype.

Authors:  Srinivasan Vedantham; Andrew Karellas; Sankararaman Suryanarayanan; Steven K Onishi
Journal:  Med Phys       Date:  2004-06       Impact factor: 4.071

4.  A simple method for determining the modulation transfer function in digital radiography.

Authors:  H Fujita; D Y Tsai; T Itoh; K Doi; J Morishita; K Ueda; A Ohtsuka
Journal:  IEEE Trans Med Imaging       Date:  1992       Impact factor: 10.048

5.  DQE(f) of four generations of computed radiography acquisition devices.

Authors:  J T Dobbins; D L Ergun; L Rutz; D A Hinshaw; H Blume; D C Clark
Journal:  Med Phys       Date:  1995-10       Impact factor: 4.071

6.  Micro-angiography for neuro-vascular imaging. I. Experimental evaluation and feasibility.

Authors:  Arundhuti Ganguly; Stephen Rudin; Daniel R Bednarek; Kenneth R Hoffmann; Iacovos S Kyprianou
Journal:  Med Phys       Date:  2003-11       Impact factor: 4.071

  6 in total
  5 in total

1.  Cone-beam micro-CT system based on LabVIEW software.

Authors:  Ciprian N Ionita; Keneth R Hoffmann; Daniel R Bednarek; Ravishankar Chityala; Stephen Rudin
Journal:  J Digit Imaging       Date:  2007-02-28       Impact factor: 4.056

2.  A practical exposure-equivalent metric for instrumentation noise in x-ray imaging systems.

Authors:  G K Yadava; A T Kuhls-Gilcrist; S Rudin; V K Patel; K R Hoffmann; D R Bednarek
Journal:  Phys Med Biol       Date:  2008-08-22       Impact factor: 3.609

3.  New light-amplifier-based detector designs for high spatial resolution and high sensitivity CBCT mammography and fluoroscopy.

Authors:  Stephen Rudin; Andrew T Kuhls; Girijesh K Yadava; Gaurav C Josan; Ye Wu; Ravishankar N Chityala; Hussain S Rangwala; N Ciprian Ionita; Kenneth R Hoffmann; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2006-12-02

4.  Evaluation of intracranial aneurysm coil embolization in phantoms and patients using a high-resolution Microangiographic Fluoroscope (MAF).

Authors:  Ciprian N Ionita; Amit Jain; Brendan Loughran; Swetadri Vasan S N; Daniel R Bednarek; Elad Levy; Adnan H Siddiqui; Kenneth V Snyder; L N Hopkins; Stephen Rudin
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2012-03-02

5.  Generalized Objective Performance Assessment of a New High-Sensitivity Microangiographic Fluoroscopic (HSMAF) Imaging System.

Authors:  Girijesh K Yadava; Stephen Rudin; Andrew T Kuhls-Gilcrist; Daniel R Bednarek
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2008
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.