Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray.

B Carelsen1, W Grolman, R Tange, G J Streekstra, P van Kemenade, R J Jansen, N J M Freling, M White, B Maat, W J Fokkens.   

Abstract

During cochlear implantation surgery, we use a mobile C-arm with 3D functionality to acquire per-operative 3D X-ray images. Scanning the multielectrode array is performed once before removal of the stylet and once after full insertion. When dissatisfied with the position of the multielectrode a repositioning is considered which happened occasionally. The major advantage is the extra certainty of the multielectrode array position in the cochlea with low-dose and little extra time. All cochlear implantations are now routinely scanned during surgery.

Mesh:

Year:  2007        PMID: 17298312     DOI: 10.1111/j.1365-2273.2007.01319.x

Source DB:  PubMed          Journal:  Clin Otolaryngol        ISSN: 1749-4478            Impact factor:   2.597


  11 in total

1.  Device setting modifications for 3D flatpanel imaging in skull base surgery.

Authors:  Frederike Hassepass; Wolfgang Maier; Antje Aschendorff; Stefan Bulla; Werner Vach; Roland Laszig; Tanja D Grauvogel
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-04-06       Impact factor: 2.503

Review 2.  [Surgical technique in cochlear implantation].

Authors:  M Praetorius; H Staecker; P K Plinkert
Journal:  HNO       Date:  2009-07       Impact factor: 1.284

3.  [Insertion results for Contour™ and Contour Advance™ electrodes: are there individual learning curves?].

Authors:  A Aschendorff; T Klenzner; S Arndt; R Beck; C Schild; L Röddiger; W Maier; R Laszig
Journal:  HNO       Date:  2011-05       Impact factor: 1.284

4.  Artifacts of the electrode in cochlea implantation and limits in analysis of deep insertion in cone beam tomography (CBT).

Authors:  C Güldner; S Wiegand; R Weiss; S Bien; A Sesterhenn; A Teymoortash; I Diogo
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-07-30       Impact factor: 2.503

5.  Scanning electrochemical microscopy as a novel proximity sensor for atraumatic cochlear implant insertion.

Authors:  H Watanabe; J Velmurugan; M V Mirkin; M A Svirsky; A K Lalwani; R R Llinas
Journal:  IEEE Trans Biomed Eng       Date:  2014-06       Impact factor: 4.538

6.  Electrophysiological detection of scalar changing perimodiolar cochlear electrode arrays: a long term follow-up study.

Authors:  Philipp Mittmann; I Todt; A Ernst; G Rademacher; S Mutze; S Göricke; M Schlamann; R Ramalingam; S Lang; F Christov; D Arweiler-Harbeck
Journal:  Eur Arch Otorhinolaryngol       Date:  2016-06-28       Impact factor: 2.503

7.  Electrophysiological detection of electrode fold-over in perimodiolar cochlear implant electrode arrays: a multi-center study case series.

Authors:  P Mittmann; G Lauer; A Ernst; S Mutze; F Hassepass; S Arndt; D Arweiler-Harbeck; F Christov
Journal:  Eur Arch Otorhinolaryngol       Date:  2019-09-24       Impact factor: 2.503

8.  Evaluation of a system for high-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery.

Authors:  Daniel J Mirota; Ali Uneri; Sebastian Schafer; Sajendra Nithiananthan; Douglas D Reh; Masaru Ishii; Gary L Gallia; Russell H Taylor; Gregory D Hager; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2013-01-28       Impact factor: 10.048

9.  Three-dimensional hard and soft tissue imaging of the human cochlea by scanning laser optical tomography (SLOT).

Authors:  Nadine Tinne; Georgios C Antonopoulos; Saleh Mohebbi; José Andrade; Lena Nolte; Heiko Meyer; Alexander Heisterkamp; Omid Majdani; Tammo Ripken
Journal:  PLoS One       Date:  2017-09-05       Impact factor: 3.240

10.  Evaluation of the Relationship between the NRT-Ratio, Cochlear Anatomy, and Insertions Depth of Perimodiolar Cochlear Implant Electrodes.

Authors:  Philipp Mittmann; Grit Rademacher; Sven Mutze; Frederike Hassepass; Arneborg Ernst; Ingo Todt
Journal:  Biomed Res Int       Date:  2015-12-29       Impact factor: 3.411

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.