Literature DB >> 23372078

Evaluation of a system for high-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery.

Daniel J Mirota1, Ali Uneri, Sebastian Schafer, Sajendra Nithiananthan, Douglas D Reh, Masaru Ishii, Gary L Gallia, Russell H Taylor, Gregory D Hager, Jeffrey H Siewerdsen.   

Abstract

The safety of endoscopic skull base surgery can be enhanced by accurate navigation in preoperative computed tomography (CT) or, more recently, intraoperative cone-beam CT (CBCT). The ability to register real-time endoscopic video with CBCT offers an additional advantage by rendering information directly within the visual scene to account for intraoperative anatomical change. However, tracker localization error (  ∼ 1-2 mm ) limits the accuracy with which video and tomographic images can be registered. This paper reports the first implementation of image-based video-CBCT registration, conducts a detailed quantitation of the dependence of registration accuracy on system parameters, and demonstrates improvement in registration accuracy achieved by the image-based approach. Performance was evaluated as a function of parameters intrinsic to the image-based approach, including system geometry, CBCT image quality, and computational runtime. Overall system performance was evaluated in a cadaver study simulating transsphenoidal skull base tumor excision. Results demonstrated significant improvement in registration accuracy with a mean reprojection distance error of 1.28 mm for the image-based approach versus 1.82 mm for the conventional tracker-based method. Image-based registration was highly robust against CBCT image quality factors of noise and resolution, permitting integration with low-dose intraoperative CBCT.

Entities:  

Mesh:

Year:  2013        PMID: 23372078      PMCID: PMC4118820          DOI: 10.1109/TMI.2013.2243464

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  32 in total

1.  Image guided surgery of the lateral skull base: testing a new dental splint registration device.

Authors:  Georg J Ledderose; Hjalmar Hagedorn; Kathrin Spiegl; Andreas Leunig; Klaus Stelter
Journal:  Comput Aided Surg       Date:  2012

2.  Influence of different registration modalities on navigation accuracy in ear, nose, and throat surgery depending on the surgical field.

Authors:  Tanja D Grauvogel; Eric Soteriou; Marc C Metzger; Ansgar Berlis; Wolfgang Maier
Journal:  Laryngoscope       Date:  2010-05       Impact factor: 3.325

Review 3.  Revision endoscopic sinus surgery.

Authors:  Noam A Cohen; David W Kennedy
Journal:  Otolaryngol Clin North Am       Date:  2006-06       Impact factor: 3.346

4.  Volume CT with a flat-panel detector on a mobile, isocentric C-arm: pre-clinical investigation in guidance of minimally invasive surgery.

Authors:  J H Siewerdsen; D J Moseley; S Burch; S K Bisland; A Bogaards; B C Wilson; D A Jaffray
Journal:  Med Phys       Date:  2005-01       Impact factor: 4.071

5.  Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray.

Authors:  B Carelsen; W Grolman; R Tange; G J Streekstra; P van Kemenade; R J Jansen; N J M Freling; M White; B Maat; W J Fokkens
Journal:  Clin Otolaryngol       Date:  2007-02       Impact factor: 2.597

6.  Intraoperative use of the Medtronic O-arm for deep brain stimulation procedures.

Authors:  F Caire; C Gantois; F Torny; D Ranoux; A Maubon; J J Moreau
Journal:  Stereotact Funct Neurosurg       Date:  2010-02-05       Impact factor: 1.875

7.  Mobile C-arm cone-beam CT for guidance of spine surgery: image quality, radiation dose, and integration with interventional guidance.

Authors:  S Schafer; S Nithiananthan; D J Mirota; A Uneri; J W Stayman; W Zbijewski; C Schmidgunst; G Kleinszig; A J Khanna; J H Siewerdsena
Journal:  Med Phys       Date:  2011-08       Impact factor: 4.071

8.  Intraoperative cone-beam CT for guidance of head and neck surgery: Assessment of dose and image quality using a C-arm prototype.

Authors:  M J Daly; J H Siewerdsen; D J Moseley; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2006-10       Impact factor: 4.071

9.  TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery.

Authors:  A Uneri; S Schafer; D J Mirota; S Nithiananthan; Y Otake; R H Taylor; G L Gallia; A J Khanna; S Lee; D D Reh; J H Siewerdsen
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-09       Impact factor: 3.421

10.  Evaluation of a system for high-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery.

Authors:  Daniel J Mirota; Ali Uneri; Sebastian Schafer; Sajendra Nithiananthan; Douglas D Reh; Masaru Ishii; Gary L Gallia; Russell H Taylor; Gregory D Hager; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2013-01-28       Impact factor: 10.048

View more
  12 in total

1.  Rendering-Based Video-CT Registration with Physical Constraints for Image-Guided Endoscopic Sinus Surgery.

Authors:  Y Otake; S Leonard; A Reiter; P Rajan; J H Siewerdsen; G L Gallia; M Ishii; R H Taylor; G D Hager
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-02-21

2.  Phantomless Auto-Calibration and Online Calibration Assessment for a Tracked Freehand 2-D Ultrasound Probe.

Authors:  Matthew Toews; William M Wells
Journal:  IEEE Trans Med Imaging       Date:  2017-09-11       Impact factor: 10.048

3.  Endoscopic-CT: Learning-Based Photometric Reconstruction for Endoscopic Sinus Surgery.

Authors:  A Reiter; S Leonard; A Sinha; M Ishii; R H Taylor; G D Hager
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-21

4.  Image-Based Navigation for Functional Endoscopic Sinus Surgery Using Structure From Motion.

Authors:  Simon Leonard; Austin Reiter; Ayushi Sinha; Masaru Ishii; Russel H Taylor; Gregory D Hager
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-21

5.  Automatic intraoperative stitching of nonoverlapping cone-beam CT acquisitions.

Authors:  Javad Fotouhi; Bernhard Fuerst; Mathias Unberath; Stefan Reichenstein; Sing Chun Lee; Alex A Johnson; Greg M Osgood; Mehran Armand; Nassir Navab
Journal:  Med Phys       Date:  2018-04-10       Impact factor: 4.071

6.  Pre-Clinical Development of Robot-Assisted Ventriculoscopy for 3D Image Reconstruction and Guidance of Deep Brain Neurosurgery.

Authors:  Prasad Vagdargi; Ali Uneri; Craig K Jones; Pengwei Wu; Runze Han; Mark G Luciano; William S Anderson; Patrick A Helm; Gregory D Hager; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Robot Bionics       Date:  2021-11-13

7.  TREK: an integrated system architecture for intraoperative cone-beam CT-guided surgery.

Authors:  A Uneri; S Schafer; D J Mirota; S Nithiananthan; Y Otake; R H Taylor; G L Gallia; A J Khanna; S Lee; D D Reh; J H Siewerdsen
Journal:  Int J Comput Assist Radiol Surg       Date:  2011-07-09       Impact factor: 3.421

8.  Evaluation of a system for high-accuracy 3D image-based registration of endoscopic video to C-arm cone-beam CT for image-guided skull base surgery.

Authors:  Daniel J Mirota; Ali Uneri; Sebastian Schafer; Sajendra Nithiananthan; Douglas D Reh; Masaru Ishii; Gary L Gallia; Russell H Taylor; Gregory D Hager; Jeffrey H Siewerdsen
Journal:  IEEE Trans Med Imaging       Date:  2013-01-28       Impact factor: 10.048

9.  Augmented reality and cone beam CT guidance for transoral robotic surgery.

Authors:  Wen P Liu; Jeremy D Richmon; Jonathan M Sorger; Mahdi Azizian; Russell H Taylor
Journal:  J Robot Surg       Date:  2015-07-21

10.  The feasibility of endoscopy-CT image registration in the head and neck without prospective endoscope tracking.

Authors:  W Scott Ingram; Jinzhong Yang; Beth M Beadle; Richard Wendt; Arvind Rao; Xin A Wang; Laurence E Court
Journal:  PLoS One       Date:  2017-05-18       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.