Literature DB >> 22481545

Device setting modifications for 3D flatpanel imaging in skull base surgery.

Frederike Hassepass1, Wolfgang Maier, Antje Aschendorff, Stefan Bulla, Werner Vach, Roland Laszig, Tanja D Grauvogel.   

Abstract

To evaluate the image quality and clinical implementation after setting modification of a three-dimensional isocentric C-arm fluoroscopic image intensifier system combined with a digital flatpanel detector as a new tool for sinus and petrous bone surgery. Image acquisition was performed using two cadaveric heads. Experimental design was oriented to the clinically sensible intraoperative setup. Different tube currents and orbital movements of the C-arm system were evaluated for image quality by three otolaryngological surgeons using predetermined landmarks. Modification of the X-ray intensity did not attain statistically significant values compared to the X-ray-intensity predetermined by producer (12.0-18.5 mA, p > 0.05) for either sinus or for petrous bone scans. Elliptical orbital movement resulted in significantly superior image quality than data sets acquired by circular orbital movement (3.194 vs. 2.809, p < 0.0001). New C-arm systems with 3D-capabiltity offer a promising tool for intraoperative near real-time image guidance. Image quality of the skull base can be improved significantly with optimized system settings.

Entities:  

Mesh:

Year:  2012        PMID: 22481545     DOI: 10.1007/s00405-012-2010-y

Source DB:  PubMed          Journal:  Eur Arch Otorhinolaryngol        ISSN: 0937-4477            Impact factor:   2.503


  18 in total

1.  Intraoperative Iso-C C-arm navigation in craniospinal surgery: the first 60 cases.

Authors:  Jonathan S Hott; Vivek R Deshmukh; Jeffrey D Klopfenstein; Volker K H Sonntag; Curtis A Dickman; Robert F Spetzler; Stephen M Papadopoulos
Journal:  Neurosurgery       Date:  2004-05       Impact factor: 4.654

2.  Intraoperative cone-beam CT for guidance of temporal bone surgery.

Authors:  Mark A Rafferty; Jeffrey H Siewerdsen; Yvonne Chan; Michael J Daly; Douglas J Moseley; David A Jaffray; Jonathan C Irish
Journal:  Otolaryngol Head Neck Surg       Date:  2006-05       Impact factor: 3.497

3.  Radiation dosimetry of the FluoroCAT scan for real-time endoscopic sinus surgery.

Authors:  Casey R A Manarey; Vijay K Anand
Journal:  Otolaryngol Head Neck Surg       Date:  2006-09       Impact factor: 3.497

4.  Cochlear implant electrode array insertion monitoring with intra-operative 3D rotational X-ray.

Authors:  B Carelsen; W Grolman; R Tange; G J Streekstra; P van Kemenade; R J Jansen; N J M Freling; M White; B Maat; W J Fokkens
Journal:  Clin Otolaryngol       Date:  2007-02       Impact factor: 2.597

5.  Navigated implantation after microsurgical bone transfer using intraoperatively acquired cone-beam computed tomography data sets.

Authors:  M Heiland; P Pohlenz; M Blessmann; H Werle; M Fraederich; R Schmelzle; F A S Blake
Journal:  Int J Oral Maxillofac Surg       Date:  2007-09-05       Impact factor: 2.789

6.  Temporal bone imaging: comparison of flat panel volume CT and multisection CT.

Authors:  O Majdani; K Thews; S Bartling; M Leinung; C Dalchow; R Labadie; T Lenarz; G Heidrich
Journal:  AJNR Am J Neuroradiol       Date:  2009-04-15       Impact factor: 3.825

7.  Fluoroscopic frameless stereotaxy for transsphenoidal surgery.

Authors:  J A Jane; K Thapar; T D Alden; E R Laws
Journal:  Neurosurgery       Date:  2001-06       Impact factor: 4.654

8.  Clinical utility of intraoperative volume computed tomography scanner for endoscopic sinonasal and skull base procedures.

Authors:  Pete S Batra; Seth J Kanowitz; Martin J Citardi
Journal:  Am J Rhinol       Date:  2008 Sep-Oct

9.  Transsphenoidal pituitary macroadenomas resection guided by PoleStar N20 low-field intraoperative magnetic resonance imaging: comparison with early postoperative high-field magnetic resonance imaging.

Authors:  Jin-Song Wu; Xue-Fei Shou; Cheng-Jun Yao; Yong-Fei Wang; Dong-Xiao Zhuang; Ying Mao; Shi-Qi Li; Liang-Fu Zhou
Journal:  Neurosurgery       Date:  2009-07       Impact factor: 4.654

10.  Intraoperative acquisition of three-dimensional imaging for frameless stereotactic guidance during transsphenoidal pituitary surgery using the Arcadis Orbic System.

Authors:  W Christopher Fox; Scott Wawrzyniak; William F Chandler
Journal:  J Neurosurg       Date:  2008-04       Impact factor: 5.115

View more
  2 in total

1.  A mobile isocentric C-arm for intraoperative cone-beam CT: Technical assessment of dose and 3D imaging performance.

Authors:  N M Sheth; T De Silva; A Uneri; M Ketcha; R Han; R Vijayan; G M Osgood; J H Siewerdsen
Journal:  Med Phys       Date:  2020-01-06       Impact factor: 4.506

Review 2.  Pediatric radiology in oto-rhino-laryngology.

Authors:  Thekla von Kalle; Assen Koitschev
Journal:  GMS Curr Top Otorhinolaryngol Head Neck Surg       Date:  2014-12-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.