Literature DB >> 24147264

Reliability of preoperative measurement with standardized templating in Total Knee Arthroplasty.

Daniel Hernandez-Vaquero1, Ferran Abat, Juan Sarasquete, Juan Carlos Monllau.   

Abstract

AIM: To investigate the correlation between preoperative measurement in total knee arthroplasty and the prosthetic size implanted.
METHODS: A prospective double-blind study of 50 arthroplasties was performed. Firstly, the reliability and correspondence between the size of said measurement and the actual implant utilized was determined. Secondly, the existing correlation between the intra- and interobserver determinations with the intraclass correlation coefficient was analyzed.
RESULTS: An overall correspondence of 54%, improving up to 92% when the measured size admitted a difference of one size, was found. Good intra- and interobserver reliability with an intraclass correlation coefficient greater than 0.90 (P < 0.001) was also discovered.
CONCLUSION: Agreement between the preoperative measurement with standardized acetate templates and the prosthetic size implanted can be considered satisfactory. We thus conclude it is a reproducible technique.

Entities:  

Keywords:  Correlation coefficient; Preoperative measurement; Prosthetic size; Templating; Total knee arthroplasty

Year:  2013        PMID: 24147264      PMCID: PMC3801248          DOI: 10.5312/wjo.v4.i4.287

Source DB:  PubMed          Journal:  World J Orthop        ISSN: 2218-5836


  26 in total

1.  [Planning and performance of orthopedic surgery with the help of individual templates].

Authors:  N Schiffers; E Schkommodau; F Portheine; K Radermacher; H W Staudte
Journal:  Orthopade       Date:  2000-07       Impact factor: 1.087

2.  Preoperative planning for total hip arthroplasty. Quantitating its utility and precision.

Authors:  J L Knight; R D Atwater
Journal:  J Arthroplasty       Date:  1992       Impact factor: 4.757

3.  Effect of training level on accuracy of digital templating in primary total hip and knee arthroplasty.

Authors:  Andrew R Hsu; Jeffrey D Kim; Sanjeev Bhatia; Brett R Levine
Journal:  Orthopedics       Date:  2012-02-17       Impact factor: 1.390

4.  Reliability of preoperative templating in total knee arthroplasty.

Authors:  Nadim Aslam; Steven Lo; Kugan Nagarajah; Chandra Pasapula; Mo Akmal
Journal:  Acta Orthop Belg       Date:  2004-12       Impact factor: 0.500

5.  Digital templating in total hip arthroplasty.

Authors:  James V Bono
Journal:  J Bone Joint Surg Am       Date:  2004       Impact factor: 5.284

Review 6.  Component alignment in total knee arthroplasty.

Authors:  James Benjamin
Journal:  Instr Course Lect       Date:  2006

7.  The role of preoperative templating in total knee arthroplasty: comparison of three prostheses.

Authors:  D W J Howcroft; M J Fehily; C Peck; A Fox; B Dillon; D S Johnson
Journal:  Knee       Date:  2006-10-05       Impact factor: 2.199

Review 8.  Lessons of 30 years of total hip arthroplasty.

Authors:  M E Müller
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

9.  Comparison of analog and digital preoperative planning in total hip and knee arthroplasties. A prospective study of 173 hips and 65 total knees.

Authors:  Bertram The; Ron L Diercks; Peter M A van Ooijen; Jim R van Horn
Journal:  Acta Orthop       Date:  2005-02       Impact factor: 3.717

10.  Anthropometric measurements of the human knee: correlation to the sizing of current knee arthroplasty systems.

Authors:  Kirby Hitt; John R Shurman; Kenneth Greene; Joseph McCarthy; Joseph Moskal; Tim Hoeman; Michael A Mont
Journal:  J Bone Joint Surg Am       Date:  2003       Impact factor: 5.284

View more
  6 in total

1.  Pre-operative templating for knee arthroplasty shows low accuracy with standard X-rays.

Authors:  Nelson Hiroyuki Miyabe Ooka; André Luiz Siqueira Campos; Vitor Mudesto da Fonseca; Luis Edmundo Oliveira Rodrigues; Edmilson Barbosa Filho; José Sérgio Franco; Rodrigo Satamini Pires E Albuquerque; Vinicius Schott Gameiro
Journal:  Int Orthop       Date:  2018-01-15       Impact factor: 3.075

2.  Magnification assessment of radiographs for knee replacement (MARKeR) - A pilot study in a low-resource setting.

Authors:  Marlon M Mencia; Raakesh Goalan; Kimani White
Journal:  Acta Radiol Open       Date:  2022-04-19

3.  Fallacies of CT based component size prediction in total knee arthroplasty - Are patient specific instruments the answer?

Authors:  Raju Vaishya; Vipul Vijay; Midhun Krishnan; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2017-11-10

Review 4.  Computed tomography based 3D printed patient specific blocks for total knee replacement.

Authors:  Raju Vaishya; Vipul Vijay; Abhishek Vaish; Amit K Agarwal
Journal:  J Clin Orthop Trauma       Date:  2018-07-18

5.  Total Knee Replacement Sizing: Shoe Size Is a Better Predictor for Implant Size than Body Height.

Authors:  Sarah Trainor; Jamie Collins; Hannah Mulvey; Wolfgang Fitz
Journal:  Arch Bone Jt Surg       Date:  2018-03

6.  Agreement in component size between preoperative measurement, navigation and final implant in total knee replacement.

Authors:  Daniel Hernández-Vaquero; Alfonso Noriega-Fernandez; Sergio Roncero-Gonzalez; Ivan Perez-Coto; Andres A Sierra-Pereira; Manuel A Sandoval-Garcia
Journal:  J Orthop Translat       Date:  2018-11-22       Impact factor: 5.191

  6 in total