Literature DB >> 30013289

The 3-dot circle: A reliable method for safe and efficient digital templating of the acetabular component.

Firas Arnaout1, Varun Dewan1, Christos Paliobeis1.   

Abstract

BACKGROUND: Templating for preoperative planning of joint arthroplasty has followed the evolution of digital templating software.
OBJECTIVE: This study aims to provide a safe, reliable and reproducible method for prediction of acetabular component size based on measurement of the radiographic femoral head diameter, with the aid of templating software.
METHODS: A defined methodology for femoral head measurement was applied to 97 consecutive, calibrated digital pelvic radiographs. Based on radiographic femoral head diameter, the minimum acetabular shell diameter was calculated and then compared to the size of the implanted acetabular shells.
RESULTS: This method predicted safe minimum acetabular component size with an accuracy of 95.9% with a high inter-observer reliability of 97.6%.
CONCLUSIONS: This study presents a simple, reproducible and accurate method for templating of the minimum safest acetabular component diameter.

Entities:  

Keywords:  Hip replacement; Preoperative planning; Preoperative templating; THR

Year:  2018        PMID: 30013289      PMCID: PMC6043873          DOI: 10.1016/j.jor.2018.03.027

Source DB:  PubMed          Journal:  J Orthop        ISSN: 0972-978X


  18 in total

1.  A simple guide to determine the magnification of radiographs and to improve the accuracy of preoperative templating.

Authors:  K S Conn; M T Clarke; J P Hallett
Journal:  J Bone Joint Surg Br       Date:  2002-03

2.  Preoperative planning for total hip arthroplasty. Quantitating its utility and precision.

Authors:  J L Knight; R D Atwater
Journal:  J Arthroplasty       Date:  1992       Impact factor: 4.757

3.  Accuracy of digital templating in total hip arthroplasty.

Authors:  David R Whiddon; James V Bono; Jason E Lang; Eric L Smith; Aaron K Salyapongse
Journal:  Am J Orthop (Belle Mead NJ)       Date:  2011-08

4.  Primary hip arthroplasty templating on standard radiographs. A stepwise approach.

Authors:  Thierry Scheerlinck
Journal:  Acta Orthop Belg       Date:  2010-08       Impact factor: 0.500

5.  The utility and precision of analogue and digital preoperative planning for total hip arthroplasty.

Authors:  Alejandro González Della Valle; Fernando Comba; Nicole Taveras; Eduardo A Salvati
Journal:  Int Orthop       Date:  2007-04-03       Impact factor: 3.075

6.  Cartilage thickness in the hip joint measured by MRI and stereology--a methodological study.

Authors:  I Mechlenburg; J R Nyengaard; J Gelineck; K Soballe
Journal:  Osteoarthritis Cartilage       Date:  2006-12-13       Impact factor: 6.576

7.  Preoperative planning of total hip replacement using the TraumaCad™ system.

Authors:  Ely Liviu Steinberg; Nadav Shasha; Aharon Menahem; Shmuel Dekel
Journal:  Arch Orthop Trauma Surg       Date:  2010-01-13       Impact factor: 3.067

8.  A novel method of accurately calculating the radiological magnification of the hip.

Authors:  R J King; P Makrides; J A Gill; S Karthikeyan; S J Krikler; D R Griffin
Journal:  J Bone Joint Surg Br       Date:  2009-09

Review 9.  Lessons of 30 years of total hip arthroplasty.

Authors:  M E Müller
Journal:  Clin Orthop Relat Res       Date:  1992-01       Impact factor: 4.176

10.  A new digital preoperative planning method for total hip arthroplasties.

Authors:  Hendrikus J A Crooijmans; Armand M R P Laumen; Carola van Pul; Jan B A van Mourik
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.