[Development of hip resurfacing].

H Rechl1, H Pilge, M Rudert.   

Abstract

Total hip replacement in its current form has proved to be very effective in late middle-aged and elderly patients. However, in the younger patient population the survival rate is still not acceptable. Since the very beginning of hip resurfacing, the procedure has been advocated as an attractive concept to preserve proximal femoral bone stock. Furthermore, it is supposed to optimize stress transfer to the proximal femur and because of the large head size improves joint stability and range of motion. The failure of previous resurfacings has been described to be due to inappropriate materials, poor design, and poor instrumentation and not as an inherent problem of the procedure itself. Progress in materials and material design (metal-on-metal) as well in experience in surgical technique seem to have overcome formerly experienced difficulties. This means a lower rate of femoral neck fractures and aseptic loosenings, at least in the short-term and midterm follow-up of patients with good function. High manufacturing standards are required to consistently produce low-wear metal-on-metal bearings and it is still unclear whether high metal ion levels, which occur in all patients with metal-on-metal hip replacements, have any biologic effect. At least so far there is no evidence of any negative clinical effect in this regard. Only long-term results in a higher number of patients and a more widespread use of this procedure will tell whether early success is durable or it is just a bone-preserving, intermittent step before conventional total hip replacement.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18584148     DOI: 10.1007/s00132-008-1312-7

Source DB:  PubMed          Journal:  Orthopade        ISSN: 0085-4530            Impact factor:   1.087


  31 in total

1.  Experience with the Metasul total hip bearing system.

Authors:  B G Weber
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

2.  Surface replacement of the hip joint.

Authors:  S Tanaka
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

3.  Socket and cup surface replacement of the hip.

Authors:  A Nishio; M Eguchi; N Kaibara
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

4.  Metal on metal surface replacement of the hip. Experience of the McMinn prothesis.

Authors:  D McMinn; R Treacy; K Lin; P Pynsent
Journal:  Clin Orthop Relat Res       Date:  1996-08       Impact factor: 4.176

5.  THARIES surface replacements: a review of the first 100 cases.

Authors:  H C Amstutz; A Graff-Radford; T A Gruen; I C Clarke
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

6.  Analysis of 118 second-generation metal-on-metal retrieved hip implants.

Authors:  H P Sieber; C B Rieker; P Köttig
Journal:  J Bone Joint Surg Br       Date:  1999-01

7.  Some anatomical and mechanical considerations relevant to the surface replacement of the femoral head.

Authors:  M A Freeman
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

8.  Cemented double cup arthroplasty of the hip: a 5 year experience with the ICLH prosthesis.

Authors:  M A Freeman; H U Cameron; G C Brown
Journal:  Clin Orthop Relat Res       Date:  1978 Jul-Aug       Impact factor: 4.176

9.  Precision-fit surface hemiarthroplasty for femoral head osteonecrosis. Long-term results.

Authors:  H C Amstutz; P Grigoris; M R Safran; M J Grecula; P A Campbell; T P Schmalzried
Journal:  J Bone Joint Surg Br       Date:  1994-05

10.  The viability of the femoral head after resurfacing hip arthroplasty in humans.

Authors:  D W Howie; B L Cornish; B Vernon-Roberts
Journal:  Clin Orthop Relat Res       Date:  1993-06       Impact factor: 4.176

View more
  1 in total

Review 1.  [Results of 5 to 10-year follow-up after hip resurfacing. A systematic analysis of the literature on long-term results].

Authors:  M C M Klotz; S J Breusch; M Hassenpflug; R G Bitsch
Journal:  Orthopade       Date:  2012-06       Impact factor: 1.087

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.