Literature DB >> 17267632

Evaluation of the performance of the automated NucliSENS easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for high-throughput monitoring of human immunodeficiency virus load.

W Stevens1, P Horsfield, L E Scott.   

Abstract

This study presents the data of an evaluation of the automated Nuclisens easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for testing of high-volume human immunodeficiency virus (HIV) load. This represents a follow-up of a previous study investigating the performance of the real-time Nuclisens assay using the semiautomated NucliSENS miniMAG extraction procedure. Three hundred eighteen patient samples were analyzed using both methods. The easyMAG-EasyQ HIV type 1 system has a higher sensitivity and broader dynamic range than the Cobas AmpliPrep-AMPLICOR system when the standard Roche assay is used alone, 25 to 3,000,000 IU/ml versus 400 to 750,000 HIV RNA copies/ml, respectively. There was significant correlation between the assays (0.93; P < 0.0001), with good accuracy (percent similarity mean mu = 96%), good precision (percent similarity standard deviation = 4.97%), and overall good agreement with a low percent similarity coefficient of variation of 5.17 to 6.11%. Bland-Altman analysis revealed that the AMPLICOR assay generated higher values than the EasyQ combination, with 95% of results within clinically acceptable limits. The throughput of samples was greatly improved using the easyMAG-EasyQ system, allowing 144 samples to be processed within 6 h. The potential for contamination has been dramatically reduced using the automated extraction system. Additional negative controls have been added to the kit to monitor for contamination based on the South African experience. This assay thus presents a real option for monitoring HIV load assays in high-volume testing environments.

Entities:  

Mesh:

Substances:

Year:  2007        PMID: 17267632      PMCID: PMC1865857          DOI: 10.1128/JCM.01540-06

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  6 in total

1.  Principles of quantitation of viral loads using nucleic acid sequence-based amplification in combination with homogeneous detection using molecular beacons.

Authors:  Jos J A M Weusten; Wim M Carpay; Tom A M Oosterlaken; Martien C A van Zuijlen; Paul A van de Wiel
Journal:  Nucleic Acids Res       Date:  2002-03-15       Impact factor: 16.971

2.  Multiple method comparison: statistical model using percentage similarity.

Authors:  Lesley E Scott; Jacky S Galpin; Deborah K Glencross
Journal:  Cytometry B Clin Cytom       Date:  2003-07       Impact factor: 3.058

3.  Evaluation of the NucliSens EasyQ assay in HIV-1-infected individuals in South Africa.

Authors:  W Stevens; T Wiggill; P Horsfield; L Coetzee; L E Scott
Journal:  J Virol Methods       Date:  2004-12-15       Impact factor: 2.014

4.  Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma.

Authors:  C de Mendoza; M Koppelman; B Montès; V Ferre; V Soriano; H Cuypers; M Segondy; T Oosterlaken
Journal:  J Virol Methods       Date:  2005-04-25       Impact factor: 2.014

5.  Quantitative detection of HIV-1 RNA using NucliSens EasyQ HIV-1 assay.

Authors:  Jun Yao; Zhen Liu; Lung-Sang Ko; Gang Pan; Yan Jiang
Journal:  J Virol Methods       Date:  2005-10       Impact factor: 2.014

6.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

  6 in total
  11 in total

1.  Evaluation of a high-throughput diagnostic system for detection of HIV-1 in dried blood spot samples from infants in Mozambique.

Authors:  Ilesh V Jani; Jennifer Sabatier; Adolfo Vubil; Shambavi Subbarao; Dulce Bila; Amina de Sousa; Nédio Mabunda; Albert Garcia; Beth Skaggs; Dennis Ellenberger; Artur Ramos
Journal:  J Clin Microbiol       Date:  2012-01-25       Impact factor: 5.948

2.  Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

Authors:  Sihong Xu; Aijing Song; Jianhui Nie; Xiuhua Li; Youchun Wang
Journal:  Mol Diagn Ther       Date:  2010-10-01       Impact factor: 4.074

3.  Comparison of the NucliSens easyMAG and Qiagen BioRobot 9604 nucleic acid extraction systems for detection of RNA and DNA respiratory viruses in nasopharyngeal aspirate samples.

Authors:  Kwok Hung Chan; Wing Cheong Yam; Chiu Mei Pang; Kit Man Chan; Siu Yan Lam; Kam Fai Lo; Leo L M Poon; J S Malik Peiris
Journal:  J Clin Microbiol       Date:  2008-05-07       Impact factor: 5.948

4.  Evaluation of the Cavidi ExaVir Load assay (version 3) for plasma human immunodeficiency virus type 1 load monitoring.

Authors:  Vicki L Greengrass; Megan M Plate; Pauline M Steele; Justin T Denholm; Catherine L Cherry; Lisa M Morris; Anna Hearps; Suzanne M Crowe
Journal:  J Clin Microbiol       Date:  2009-07-15       Impact factor: 5.948

5.  Does Size Matter? Comparison of Extraction Yields for Different-Sized DNA Fragments by Seven Different Routine and Four New Circulating Cell-Free Extraction Methods.

Authors:  Linda Cook; Kimberly Starr; Jerry Boonyaratanakornkit; Randall Hayden; Soya S Sam; Angela M Caliendo
Journal:  J Clin Microbiol       Date:  2018-11-27       Impact factor: 5.948

6.  Clinical evaluation of NucliSENS magnetic extraction and NucliSENS analyte-specific reagents for real-time detection of human metapneumovirus in pediatric respiratory specimens.

Authors:  Christine C Ginocchio; Ryhana Manji; Madhavi Lotlikar; Fan Zhang
Journal:  J Clin Microbiol       Date:  2008-02-13       Impact factor: 5.948

7.  Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

Authors:  Lesley E Scott; Lara D Noble; Jackie Moloi; Linda Erasmus; Willem D F Venter; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

8.  Ten years of external quality assessment of human immunodeficiency virus type 1 RNA quantification.

Authors:  Brigitte Senechal; Vivienne L A James
Journal:  J Clin Microbiol       Date:  2012-09-05       Impact factor: 5.948

9.  Comparison of eMAG™ versus NucliSENS® EasyMAG® performance on clinical specimens.

Authors:  Magali Garcia; Céline Chessa; Anne Bourgoin; Geneviève Giraudeau; Chloé Plouzeau; Gérard Agius; Nicolas Lévêque; Agnès Beby-Defaux
Journal:  J Clin Virol       Date:  2017-01-29       Impact factor: 3.168

Review 10.  Systematic review of the performance of HIV viral load technologies on plasma samples.

Authors:  Kimberly A Sollis; Pieter W Smit; Susan Fiscus; Nathan Ford; Marco Vitoria; Shaffiq Essajee; David Barnett; Ben Cheng; Suzanne M Crowe; Thomas Denny; Alan Landay; Wendy Stevens; Vincent Habiyambere; Jos Perrins; Rosanna W Peeling
Journal:  PLoS One       Date:  2014-02-18       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.