Literature DB >> 15664057

Evaluation of the NucliSens EasyQ assay in HIV-1-infected individuals in South Africa.

W Stevens1, T Wiggill, P Horsfield, L Coetzee, L E Scott.   

Abstract

We compared the performance of the NucliSens EasyQ assay (bioMerieux) combined with the manual NucliSens miniMag extraction methodology to the Roche Cobas Ampliprep/Standard Amplicor Monitor methodology (Roche Diagnostics) for HIV-1 RNA quantitation in HIV-1-infected individuals in South Africa. Plasma samples (284) from HIV sero-positive patients at different stages of infection were analyzed. The distribution of results was typical of the clinical samples received at the laboratory where 20% have viral load results <400 copies/ml (2.6 log) and 18% have viral load results >750000 copies/ml (5.8 log) using the Roche Amplicor Monitor standard assay. All statistical analyses were performed using log10-transformed values for all the variables in the analyses, i.e. log10EasyQIU/ml, and log10RNA (log10 copies/ml, Amplicor). Roche values were converted from RNA copies per ml to IU/ml by multiplying the Roche value by 0.51. HIV RNA levels quantitated by the NucliSens EasyQ assay correlated significantly with those of the Roche Cobas Amplicor Monitor assay (r=0.874, p<0.0001). Reproducibility of the NucliSens EasyQ assay in the log6IU range yielded CV variance of 1.3-2.84% for two well-trained technologists. In addition, a retrospective evaluation of the performance of the NucliSens EasyQ assay in 102 runs (2448) samples was conducted in the laboratory over a 4-month interval. Factors considered during this evaluation included time taken to perform the assay, volume requirements, number of required repeats, potential for contamination.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15664057     DOI: 10.1016/j.jviromet.2004.11.009

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  17 in total

1.  Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

Authors:  Sihong Xu; Aijing Song; Jianhui Nie; Xiuhua Li; Youchun Wang
Journal:  Mol Diagn Ther       Date:  2010-10-01       Impact factor: 4.074

2.  Accuracy of immunological criteria for identifying virological failure in children on antiretroviral therapy - the IeDEA Southern Africa Collaboration.

Authors:  Mary-Ann Davies; Andrew Boulle; Brian Eley; Harry Moultrie; Karl Technau; Helena Rabie; Gilles van Cutsem; Janet Giddy; Robin Wood; Matthias Egger; Olivia Keiser
Journal:  Trop Med Int Health       Date:  2011-08-11       Impact factor: 2.622

3.  Evaluation of a real-time nucleic acid sequence-based amplification assay using molecular beacons for detection of human immunodeficiency virus type 1.

Authors:  D R McClernon; C Vavro; M St Clair
Journal:  J Clin Microbiol       Date:  2006-06       Impact factor: 5.948

4.  Real-time nucleic acid sequence-based amplification using molecular beacons for detection of enterovirus RNA in clinical specimens.

Authors:  Marie L Landry; Robin Garner; David Ferguson
Journal:  J Clin Microbiol       Date:  2005-07       Impact factor: 5.948

5.  Evaluation of NucliSens easyMAG for automated nucleic acid extraction from various clinical specimens.

Authors:  K Loens; K Bergs; D Ursi; H Goossens; M Ieven
Journal:  J Clin Microbiol       Date:  2006-12-13       Impact factor: 5.948

6.  The role of targeted viral load testing in diagnosing virological failure in children on antiretroviral therapy with immunological failure.

Authors:  Mary-Ann Davies; Andrew Boulle; Karl Technau; Brian Eley; Harry Moultrie; Helena Rabie; Daniela Garone; Janet Giddy; Robin Wood; Matthias Egger; Olivia Keiser
Journal:  Trop Med Int Health       Date:  2012-09-14       Impact factor: 2.622

7.  Evaluation of the performance of the automated NucliSENS easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for high-throughput monitoring of human immunodeficiency virus load.

Authors:  W Stevens; P Horsfield; L E Scott
Journal:  J Clin Microbiol       Date:  2007-01-31       Impact factor: 5.948

8.  Virologic failure and second-line antiretroviral therapy in children in South Africa--the IeDEA Southern Africa collaboration.

Authors:  Mary-Ann Davies; Harry Moultrie; Brian Eley; Helena Rabie; Gilles Van Cutsem; Janet Giddy; Robin Wood; Karl Technau; Olivia Keiser; Matthias Egger; Andrew Boulle
Journal:  J Acquir Immune Defic Syndr       Date:  2011-03-01       Impact factor: 3.731

9.  Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

Authors:  Lesley E Scott; Lara D Noble; Jackie Moloi; Linda Erasmus; Willem D F Venter; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

10.  Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.

Authors:  Africa Holguín; Marisa López; Mar Molinero; Vincent Soriano
Journal:  J Clin Microbiol       Date:  2008-07-02       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.