Literature DB >> 15893566

Multicenter evaluation of the NucliSens EasyQ HIV-1 v1.1 assay for the quantitative detection of HIV-1 RNA in plasma.

C de Mendoza1, M Koppelman, B Montès, V Ferre, V Soriano, H Cuypers, M Segondy, T Oosterlaken.   

Abstract

The Nuclisens EasyQ HIV-1 v1.1 assay (Biomerieux) is a real-time detection method combined with NASBA technology designed to measure plasma HIV-RNA. Its performance was assessed in 1008 clinical specimens collected from individuals infected with clade B (774) and non-B (234) HIV-1 variants at four European laboratories. The results were compared with those obtained using three other commercial viral load assays: Cobas Amplicor Monitor HIV-1 v1.5 (Roche), Versant HIV-1 RNA assay (Bayer) and Nuclisens HIV-1 QT (Biomerieux). Overall, the linearity, specificity and reproducibility of the EasyQ assay was comparable with that from the other tests. The correlation coefficient (R) between methodologies was 0.85 for Amplicor; 0.87 for Versant; and 0.91 for Nuclisens. The specificity of the assay was 99.4%. Of note, Versant missed 17% of specimens with non-B subtypes which could be detected by EasyQ, while Amplicor provided similar results than EasyQ. HIV-1 group O specimens were only detected by the EasyQ assay. In conclusion, the performance of the EasyQ assay seems to be similar to that of other HIV-1 viral load tests currently on the market, but it is more sensitive than Versant for HIV-1 non-B subtypes and shows a wider dynamic range than Amplicor. Moreover, as it incorporates the advantage of real-time detection procedures, it facilitates high throughput and short turnaround time.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 15893566     DOI: 10.1016/j.jviromet.2005.03.013

Source DB:  PubMed          Journal:  J Virol Methods        ISSN: 0166-0934            Impact factor:   2.014


  16 in total

1.  Performance of NucliSens HIV-1 EasyQ Version 2.0 compared with six commercially available quantitative nucleic acid assays for detection of HIV-1 in China.

Authors:  Sihong Xu; Aijing Song; Jianhui Nie; Xiuhua Li; Youchun Wang
Journal:  Mol Diagn Ther       Date:  2010-10-01       Impact factor: 4.074

2.  HIV-1 load comparison using four commercial real-time assays.

Authors:  Thomas Bourlet; Anne Signori-Schmuck; Laurent Roche; Vinca Icard; Henia Saoudin; Mary-Anne Trabaud; Jean-Claude Tardy; Patrice Morand; Bruno Pozzetto; René Ecochard; Patrice André
Journal:  J Clin Microbiol       Date:  2010-11-10       Impact factor: 5.948

3.  Evaluation of a real-time nucleic acid sequence-based amplification assay using molecular beacons for detection of human immunodeficiency virus type 1.

Authors:  D R McClernon; C Vavro; M St Clair
Journal:  J Clin Microbiol       Date:  2006-06       Impact factor: 5.948

4.  Potential of a simplified p24 assay for early diagnosis of infant human immunodeficiency virus type 1 infection in Haiti.

Authors:  Erik George; Carole Anne Beauharnais; Emilio Brignoli; Francine Noel; Gyrlande Bois; Patricia De Matteis Rouzier; Martine Altenor; Daniel Lauture; Marlène Hosty; Sapna Mehta; Peter F Wright; Jean W Pape
Journal:  J Clin Microbiol       Date:  2007-08-01       Impact factor: 5.948

5.  Comparison of the LCx human immunodeficiency virus (HIV) RNA quantitative, RealTime HIV, and COBAS AmpliPrep-COBAS TaqMan assays for quantitation of HIV type 1 RNA in plasma.

Authors:  Vincent Foulongne; Brigitte Montes; Marie-Noelle Didelot-Rousseau; Michel Segondy
Journal:  J Clin Microbiol       Date:  2006-08       Impact factor: 5.948

6.  Evaluation of the performance of the automated NucliSENS easyMAG and EasyQ systems versus the Roche AmpliPrep-AMPLICOR combination for high-throughput monitoring of human immunodeficiency virus load.

Authors:  W Stevens; P Horsfield; L E Scott
Journal:  J Clin Microbiol       Date:  2007-01-31       Impact factor: 5.948

Review 7.  Advances in developing HIV-1 viral load assays for resource-limited settings.

Authors:  ShuQi Wang; Feng Xu; Utkan Demirci
Journal:  Biotechnol Adv       Date:  2010-07-01       Impact factor: 14.227

8.  Evaluation of the Abbott m2000 RealTime human immunodeficiency virus type 1 (HIV-1) assay for HIV load monitoring in South Africa compared to the Roche Cobas AmpliPrep-Cobas Amplicor, Roche Cobas AmpliPrep-Cobas TaqMan HIV-1, and BioMerieux NucliSENS EasyQ HIV-1 assays.

Authors:  Lesley E Scott; Lara D Noble; Jackie Moloi; Linda Erasmus; Willem D F Venter; Wendy Stevens
Journal:  J Clin Microbiol       Date:  2009-05-06       Impact factor: 5.948

9.  Performance of three commercial viral load assays, Versant human immunodeficiency virus type 1 (HIV-1) RNA bDNA v3.0, Cobas AmpliPrep/Cobas TaqMan HIV-1, and NucliSens HIV-1 EasyQ v1.2, testing HIV-1 non-B subtypes and recombinant variants.

Authors:  Africa Holguín; Marisa López; Mar Molinero; Vincent Soriano
Journal:  J Clin Microbiol       Date:  2008-07-02       Impact factor: 5.948

10.  Ten years of external quality assessment of human immunodeficiency virus type 1 RNA quantification.

Authors:  Brigitte Senechal; Vivienne L A James
Journal:  J Clin Microbiol       Date:  2012-09-05       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.