Literature DB >> 14999376

[Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

K J Schnake1, B König, U Berth, R J Schroeder, F Kandziora, U Stöckle, M Raschke, N P Haas.   

Abstract

The goal of this study was to evaluate the accuracy of CT-based computer-assisted pedicle screw insertion in the thoracic spine in patients with fractures, metastases, and spondylodiscitis compared to a conventional technique. A total of 324 pedicle screws were inserted in the thoracic spines of 85 patients: 211 screws were placed using a CT-based optoelectronic navigation system assisted by an image intensifier and 113 screws were placed with a conventional technique. Screw positions were evaluated with postoperative CT scans by an independent radiologist. In the computer-assisted group, 174 (82.5%) screws were found completely within their pedicles compared with 77 (68.1%) correctly placed screws in the conventional group ( p<0.003). Despite use of the navigation system, 1.9% of the computer-assisted screws perforated the pedicle wall by more than 4 mm. The additional use of the image intensifier helped to identify the correct vertebral body and avoided cranial or caudal pedicle wall perforations.

Entities:  

Mesh:

Year:  2004        PMID: 14999376     DOI: 10.1007/s00113-003-0720-8

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  36 in total

1.  Stereotactic navigation for placement of pedicle screws in the thoracic spine.

Authors:  A S Youkilis; D J Quint; J E McGillicuddy; S M Papadopoulos
Journal:  Neurosurgery       Date:  2001-04       Impact factor: 4.654

2.  [Limits of CT-based computer navigation in spinal surgery].

Authors:  F Gebhard; L Kinzl; M Arand
Journal:  Unfallchirurg       Date:  2000-08       Impact factor: 1.000

3.  Accuracy of pedicle screw insertion: a prospective CT study in 30 low back patients.

Authors:  T Laine; K Mäkitalo; D Schlenzka; K Tallroth; M Poussa; A Alho
Journal:  Eur Spine J       Date:  1997       Impact factor: 3.134

4.  Pedicle screw instrumentation of the thoracic spine in idiopathic scoliosis.

Authors:  U R Liljenqvist; H F Halm; T M Link
Journal:  Spine (Phila Pa 1976)       Date:  1997-10-01       Impact factor: 3.468

5.  Planning and insertion of pedicle screws with computer assistance.

Authors:  U Berlemann; D Monin; E Arm; L P Nolte; C Ozdoba
Journal:  J Spinal Disord       Date:  1997-04

6.  Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine.

Authors:  L P Amiot; K Lang; M Putzier; H Zippel; H Labelle
Journal:  Spine (Phila Pa 1976)       Date:  2000-03-01       Impact factor: 3.468

7.  Radiation exposure during fluoroscopically assisted pedicle screw insertion in the lumbar spine.

Authors:  D P Jones; P A Robertson; B Lunt; S A Jackson
Journal:  Spine (Phila Pa 1976)       Date:  2000-06-15       Impact factor: 3.468

8.  [Osteosynthesis of dorsal, lumbar, and lumbosacral spine with metallic plates screwed into vertebral pedicles and articular apophyses].

Authors:  R Roy-Camille; M Roy-Camille; C Demeulenaere
Journal:  Presse Med       Date:  1970-06       Impact factor: 1.228

9.  The placement of lumbar pedicle screws using computerised stereotactic guidance.

Authors:  F P Girardi; F P Cammisa; H S Sandhu; L Alvarez
Journal:  J Bone Joint Surg Br       Date:  1999-09

10.  Spinal pedicle fixation. Confirmation of an image-based technique for screw placement.

Authors:  J C Steinmann; H N Herkowitz; H el-Kommos; D P Wesolowski
Journal:  Spine (Phila Pa 1976)       Date:  1993-10-01       Impact factor: 3.468

View more
  18 in total

Review 1.  Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies.

Authors:  Nai-Feng Tian; Qi-Shan Huang; Ping Zhou; Yang Zhou; Rui-Kai Wu; Yi Lou; Hua-Zi Xu
Journal:  Eur Spine J       Date:  2010-09-23       Impact factor: 3.134

2.  O-arm(®)-based spinal navigation and intraoperative 3D-imaging: first experiences.

Authors:  O Gonschorek; S Hauck; U Spiegl; T Weiß; R Pätzold; V Bühren
Journal:  Eur J Trauma Emerg Surg       Date:  2011-03-31       Impact factor: 3.693

3.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

4.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

5.  [Integrated navigation. Preclinical evaluation and initial clinical experience].

Authors:  U Stöckle; A Schäffler; B König; N P Haas
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

Review 6.  [Computed tomography of the musculoskeletal system].

Authors:  D Parsch; K Ludwig
Journal:  Orthopade       Date:  2006-06       Impact factor: 1.087

7.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

Review 8.  Functional outcome of computer-assisted spinal pedicle screw placement: a systematic review and meta-analysis of 23 studies including 5,992 pedicle screws.

Authors:  Rajeev Verma; Sonal Krishan; Kurt Haendlmayer; A Mohsen
Journal:  Eur Spine J       Date:  2010-01-06       Impact factor: 3.134

9.  [Best matching. Experimental comparison of different matching procedures for use in computer navigation].

Authors:  A Schäffler; B König; N P Haas; U Stöckle
Journal:  Unfallchirurg       Date:  2009-09       Impact factor: 1.000

Review 10.  Image-guided spine surgery: state of the art and future directions.

Authors:  Thorsten Tjardes; Sven Shafizadeh; Dieter Rixen; Thomas Paffrath; Bertil Bouillon; Eva S Steinhausen; Holger Baethis
Journal:  Eur Spine J       Date:  2009-09-11       Impact factor: 3.134

View more