Literature DB >> 11760340

[Precision analysis of navigation-assisted implanted thoracic and lumbar pedicled screws. A prospective clinical study].

M Arand1, E Hartwig, D Hebold, L Kinzl, F Gebhard.   

Abstract

A prospective clinical trial was performed to study the accuracy of pedicle screw placement of consecutive computer-aided and conventional techniques. Concerning the clinical performance of the navigation system, the average time of matching has been 8.4 minutes per vertebrae. For evaluation of the results, only complete intraosseous placement of the pedicle screw has been defined as correct position. Any medial or lateral perforation of the cortical structure of the pedicle was recorded as malplacement. In the CT-controlled patients complete intrapedicular placement of the screw was obtained in 36 of 45 thoracic (80%) and in 22 of 27 navigated lumbar (81%) pedicles. In the conventional cohort group 27 of 34 (79%) thoracal and 43 of 52 (83%) lumbar screws were completely in. No radicular neurologic damage, caused by a malplaced transpedicular screw has been observed in both groups. In the presented study is shown, that the application of the computer-assisted freehand navigation can improve results concerning the precision of spinal screw placement. Although, the spinal navigator has to consider a learning curve for the clinical inauguration of the system and the qualification of the implant system for computer-assisted application.

Entities:  

Mesh:

Year:  2001        PMID: 11760340     DOI: 10.1007/s001130170023

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  18 in total

1.  [Iso-C(3D0-assisted) navigated implantation of pedicle screws in thoracic lumbar vertebrae].

Authors:  K Wendl; J von Recum; A Wentzensen; P A Grützner
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

2.  [Precision of navigation-assisted surgery of the thoracic and lumbar spine].

Authors:  M Arand; M Schempf; D Hebold; S Teller; L Kinzl; F Gebhard
Journal:  Unfallchirurg       Date:  2003-11       Impact factor: 1.000

3.  [Intraoperative three-dimensional navigation for pedicle screw placement].

Authors:  P A Grützner; T Beutler; K Wendl; J von Recum; A Wentzensen; L-P Nolte
Journal:  Chirurg       Date:  2004-10       Impact factor: 0.955

4.  [Accuracy of CT-based navitation of pedicle screws in the thoracic spine compared with conventional technique].

Authors:  K J Schnake; B König; U Berth; R J Schroeder; F Kandziora; U Stöckle; M Raschke; N P Haas
Journal:  Unfallchirurg       Date:  2004-02       Impact factor: 1.000

Review 5.  Pedicle screw insertion accuracy with different assisted methods: a systematic review and meta-analysis of comparative studies.

Authors:  Nai-Feng Tian; Qi-Shan Huang; Ping Zhou; Yang Zhou; Rui-Kai Wu; Yi Lou; Hua-Zi Xu
Journal:  Eur Spine J       Date:  2010-09-23       Impact factor: 3.134

6.  O-arm(®)-based spinal navigation and intraoperative 3D-imaging: first experiences.

Authors:  O Gonschorek; S Hauck; U Spiegl; T Weiß; R Pätzold; V Bühren
Journal:  Eur J Trauma Emerg Surg       Date:  2011-03-31       Impact factor: 3.693

7.  [Computer-assisted screw placement into the posterior pelvic ring: assessment of different navigated procedures in a cadaver trial].

Authors:  D Briem; J M Rueger; P G C Begemann; Z Halata; T Bock; W Linhart; J Windolf
Journal:  Unfallchirurg       Date:  2006-08       Impact factor: 1.000

8.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

9.  [Navigated drilling for femoral head necrosis. Experimental and clinical results].

Authors:  J Beckmann; M Tingart; L Perlick; C Lüring; J Grifka; S Anders
Journal:  Orthopade       Date:  2007-05       Impact factor: 1.087

10.  Image-guided pedicle screw insertion accuracy: a meta-analysis.

Authors:  Nai-Feng Tian; Hua-Zi Xu
Journal:  Int Orthop       Date:  2009-05-08       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.