[Evaluation of image quality of the Iso C3D image processor in comparison to computer tomography. Use in the pelvic area].

B König1, U Erdmenger, R J Schröder, G Wienas, J Schaefer, M Pech, U Stöckle.   

Abstract

Intraoperative 3-D visualization using the Siremobil Iso C(3D) (Siemens, Erlangen, Germany) has been approved for use in spine and long bone surgery since its recent clinical launch. In preparation for the clinical use of the Siremobil Iso C(3D) in pelvic surgery, the aim of this study was to grade the quality of visualization in comparison with the gold standard of computer tomography in four therapy relevant pelvic regions in eight human cadavers, including SI screws to exemplify implants in the dorsal pelvic ring. Besides the influence of the body mass index and the interference of metal artefacts, visualization quality was evaluated in different pelvic regions (sacroiliac joint, acetabulum, femoral neck and anterior pelvic ring) using a score with five subgroups, rating the applicability of Siremobil Iso C(3D) in pelvic surgery. The grading of image quality in comparable standard projections was performed independently by three surgeons and three radiologists.Visualization quality appeared sufficient for both intraoperative and postoperative control in cases with a known preoperative diagnosis. There was no influence of body mass index found in any of the eight cadavers. Implants positioned in the dorsal pelvic ring reduced visualization quality, but sufficient estimation of bony structures was still possible. For primary diagnostics, computer tomography remains a clearly superior option due to better image quality. For intraoperative control of the reduction and positioning of implants in pelvic surgery, however, the additional intraoperative use of Siremobil Iso C(3D) is considered to offer clear advantages over current 2-D C-arm visualization tools.

Entities:  

Mesh:

Year:  2005        PMID: 15856147     DOI: 10.1007/s00113-004-0900-1

Source DB:  PubMed          Journal:  Unfallchirurg        ISSN: 0177-5537            Impact factor:   1.000


  4 in total

1.  [Studies on image quality, high contrast resolution and dose for the axial skeleton and limbs with a new, dedicated CT system (ISO-C-3 D)].

Authors:  C Rock; D Kotsianos; U Linsenmaier; T Fischer; R Brandl; F Vill; S Wirth; R Kaltschmidt; E Euler; K J Pfeifer; M Reiser
Journal:  Rofo       Date:  2002-02

2.  [Introduction of a new mobile C-arm/CT combination equipment (ISO-C-3D). Initial results of 3-D sectional imaging].

Authors:  C Rock; U Linsenmaier; R Brandl; D Kotsianos; S Wirth; R Kaltschmidt; E Euler; W Mutschler; K J Pfeifer
Journal:  Unfallchirurg       Date:  2001-09       Impact factor: 1.000

3.  [Radiation dosage in orthopedics -- a comparison of computer-assisted procedures].

Authors:  F Gebhard; M Kraus; E Schneider; M Arand; L Kinzl; A Hebecker; L Bätz
Journal:  Unfallchirurg       Date:  2003-06       Impact factor: 1.000

4.  [Comparative study of the quality of C-arm based 3D imaging of the talus].

Authors:  E Euler; S Wirth; U Linsenmaier; W Mutschler; K J Pfeifer; A Hebecker
Journal:  Unfallchirurg       Date:  2001-09       Impact factor: 1.000

  4 in total
  6 in total

1.  Improved surgical procedure using intraoperative navigation for the implantation of the SPG microstimulator in patients with chronic cluster headache.

Authors:  Carsten Kohlmeier; Peter Behrens; Andreas Böger; Brinda Ramachandran; Anthony Caparso; Dirk Schulze; Philipp Stude; Max Heiland; Alexandre T Assaf
Journal:  Int J Comput Assist Radiol Surg       Date:  2017-01-12       Impact factor: 2.924

2.  [Clinical experience with the Siremobil Iso-C(3D) imaging system in pelvic surgery].

Authors:  U Stöckle; B König; A Schäffler; T Zschernack; N P Haas
Journal:  Unfallchirurg       Date:  2006-01       Impact factor: 1.000

3.  [Percutaneous, 2D-fluoroscopic navigated iliosacral screw placement in the supine position: technique, possibilities, and limits].

Authors:  D Briem; J Windolf; J M Rueger
Journal:  Unfallchirurg       Date:  2007-05       Impact factor: 1.000

4.  [Drilling with 3D fluoroscopic navigation in osteonecrosis of the femoral condyle].

Authors:  M Citak; D Kendoff; T Stübig; C Krettek; T Hüfner
Journal:  Unfallchirurg       Date:  2008-05       Impact factor: 1.000

5.  [Percutaneously navigated balloon fracture reduction in a displaced acetabular fracture].

Authors:  B König; C Khodadadyan; A Schäffler; R Pflugmacher; U Stöckle
Journal:  Unfallchirurg       Date:  2007-12       Impact factor: 1.000

6.  [Percutaneous reduction and stabilization of a dislocated acetabular fracture. Case report].

Authors:  B König; K Schaser; A Schäffler; U Stöckle; N Haas
Journal:  Unfallchirurg       Date:  2006-04       Impact factor: 1.000