Literature DB >> 10087133

A PC program for estimating organ dose and effective dose values in computed tomography.

W A Kalender1, B Schmidt, M Zankl, M Schmidt.   

Abstract

Dose values in CT are specified by the manufacturers for all CT systems and operating conditions in phantoms. It is not trivial, however, to derive dose values in patients from this information. Therefore, we have developed a PC-based program which calculates organ dose and effective dose values for arbitrary scan parameters and anatomical ranges. Values for primary radiation are derived from measurements or manufacturer specifications; values for scattered radiation are derived from Monte Carlo calculations tabulated for standard anthropomorphic phantoms. Based on these values, organ doses can be computed by the program for arbitrary scan protocols in conventional and in spiral CT. Effective dose values are also provided, both with ICRP 26 and ICRP 60 tissue-weighting coefficients. Results for several standard CT protocols are presented in tabular form in this paper. In addition, potential for dose reduction is demonstrated, for example, in spiral CT and in quantitative CT. Providing realistic patient dose estimates for arbitrary CT protocols is relevant both for the physician and the patient, and it is particularly useful for educational and training purposes. The program, called WinDose, is now in use at the Erlangen University hospitals (Germany) as an information tool for radiologists and patients. Further extensions are planned.

Entities:  

Mesh:

Year:  1999        PMID: 10087133     DOI: 10.1007/s003300050709

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  43 in total

1.  Assessment of a theoretical formalism for dose estimation in CT: an anthropomorphic phantom study.

Authors:  G Brix; U Lechel; R Veit; R Truckenbrodt; G Stamm; E M Coppenrath; J Griebel; H-D Nagel
Journal:  Eur Radiol       Date:  2004-03-19       Impact factor: 5.315

2.  [CTA of carotid artery with different scanner types].

Authors:  M Lell; K Anders; C Leidecker; W Lang; W Bautz; M Uder
Journal:  Radiologe       Date:  2004-10       Impact factor: 0.635

3.  Sixteen-row multislice computed tomography in the assessment of pulmonary veins prior to ablative treatment: validation vs conventional pulmonary venography and study of reproducibility.

Authors:  Ruzica Maksimović; Filippo Cademartiri; Marcoen Scholten; Luc J Jordaens; Peter M T Pattynama
Journal:  Eur Radiol       Date:  2003-11-14       Impact factor: 5.315

4.  In-patient to isocenter KERMA ratios in CT.

Authors:  Walter Huda; Kent M Ogden; Robert L Lavallee; Marsha L Roskopf; Ernest M Scalzetti
Journal:  Med Phys       Date:  2011-10       Impact factor: 4.071

5.  Effect of CT scan protocols on x-ray-induced DNA double-strand breaks in blood lymphocytes of patients undergoing coronary CT angiography.

Authors:  M A Kuefner; S Grudzenski; J Hamann; S Achenbach; Michael Lell; K Anders; S A Schwab; L Häberle; M Löbrich; M Uder
Journal:  Eur Radiol       Date:  2010-07-13       Impact factor: 5.315

Review 6.  [Radiation hygiene in medical X-ray imaging: part 2: Assessment of radiation exposure and radiation protection measures].

Authors:  G Brix; R Veit; U Häusler
Journal:  Radiologe       Date:  2010-10       Impact factor: 0.635

7.  Survey of computed tomography techniques and absorbed dose in Italian hospitals: a comparison between two methods to estimate the dose-length product and the effective dose and to verify fulfilment of the diagnostic reference levels.

Authors:  Daniela Origgi; Sabrina Vigorito; Gaetano Villa; Massimo Bellomi; Giampiero Tosi
Journal:  Eur Radiol       Date:  2005-02-12       Impact factor: 5.315

Review 8.  Bone imaging: traditional techniques and their interpretation.

Authors:  Holger F Boehm; Thomas M Link
Journal:  Curr Osteoporos Rep       Date:  2004-06       Impact factor: 5.096

9.  Quantitative prediction of contrast enhancement from test bolus data in cardiac MSCT.

Authors:  Andreas H Mahnken; Annabella Rauscher; Ernst Klotz; Georg Mühlenbruch; Marco Das; Rolf W Günther; Joachim E Wildberger
Journal:  Eur Radiol       Date:  2006-11-18       Impact factor: 5.315

10.  Attenuation correction in cardiac PET/CT with three different CT protocols: a comparison with conventional PET.

Authors:  Michael Souvatzoglou; Frank Bengel; Raymonde Busch; Coletta Kruschke; Helga Fernolendt; Denise Lee; Markus Schwaiger; Stephan G Nekolla
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-07-28       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.